
2Regency Heat Wave Air Duct Kit
Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of
bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit.
LISTINGS AND CODE
APPROVALS
This Kit has been approved for use with Model
P36, P36D, P42, P48, P90, P95, L676S, P33S
&HZ54.Thiskithas beentestedin accordance
with National Safety Standards, and has been
certifiedbyWarnockHerseyforinstallation and
operation in the United States and Canada as
described in these Installation and Operating
Instructions.
Check with your local building code agency
before you begin your installation to ensure
compliance with local codes, including the
need for "permits" and follow-up inspections. If
any problems are encountered regarding code
approvals, or if you wish clarification on any of
the instructions contained here, contact your
local dealer.
GENERAL
INFORMATION
The Heat Wave Air Duct Kit increases the ef-
fectivenessofyourfireplacebydispersingwarm
air from the fireplace to remote locations in the
same room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.
IMPORTANT
INSTALLATION NOTES
1) Theapplianceinstallationmustconformwith
localcodesor,intheabsenceoflocalcodes,
with the current Canadian or National Gas
Codes, CAN1-B149 orANSI Z223.1 Instal-
lation Codes.
2) Theappliancewheninstalled,mustbeelec-
trically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA70 or CSAC22.1 Canadian Electrical
Code.
3) This kit is tested and safe when installed
inaccordancewiththisinstallationmanual.
Please read all instructions before starting
installation and follow all instructions care-
fully during installation.
4) Installationofthiskitmustbeperformedby
a qualified service technician.
5) The Heat Wave Kit must be installed only
as specified.Any modifications of the kit or
componentswillvoidthewarrantyandmay
cause a fire hazard.
6) Plan the location of the fireplace and the
warm air duct runs, see diagram 1 as a
guide for possible duct runs and locations.
Maximum Duct Run: 20 ft. (6.1m) per
kit.
NOTE: Airflow through the duct system is
affected by the duct length and number of
bends. Keep the length and bends to a
minimum to maximize performance.
PARTS
Included with Kit:
1 946-010 20 ft. (6.1 m) of 6" dia. flex pipe
1 946-517 Fan housing assembly
1 910-423 Variable wall rheostat
1 946-006 Air register
1 946-005 Register adaptor frame (thick)
1 946-000 Round Duct collar
1 946-001 Oval Duct collar
1 946-002 Duct adaptor (round to oval)
1 946-045 Insulation (60")
Hardware package
Ifanypartsaremissingordamaged,contact
your dealer before starting installation. DO
NOT install a damaged kit.