10 Regency®HZI234E Direct Vent Gas Insert
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The FPI Direct Vent Gas Insert must be installed in
accordance with these instructions. Carefully read
all the instructions in this manual first. Consult the
building authority having jurisdiction to determine
theneedforapermitpriortostartingtheinstallation.
NOTE: Failuretofollowtheinstructionscouldcause
a malfunction of the heater which could result in
death,seriousbodilyinjury,and/orpropertydamage.
Failure to follow these instructions may also void
your fire insurance and/or warranty.
GAS PRESSURE
TESTING
Theappliancemustbeisolatedfromthegassupply
pipingsystembyclosingitsindividualmanualshutoff
valveduringany pressuretestingof thegassupply
pipingsystemattestpressuresequaltoorlessthan
1/2 psig. (3.45 kPa).
SPECIFICATIONS
Atpressuresover1/2psig,the pipetotheunitmust
be disconnected.
Gas Input Capacity:
Natural Gas 16,500 Btu/h
Propane 15,000 Btu/h
Min. Input:
Natural Gas 12,000 Btu/h
Propane 12,000 Btu/h
Fuels: Approved for use with both natural gas,
and propane.Approved as is for use at 0' to 4,500'
(0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 127 CFM.
Vent System: 3" co-linear aluminum flex
or optional 2" intake with 3"
exhaust.
INSTALLATION INTO A
SOLID FUEL BURNING
FIREPLACE OR
FACTORY BUILT
FIREPLACE
The HZI234E Gas Inserts have been tested and
approved to be vented into any masonry fireplace
orapprovedsolidfuelburningfactorybuiltfireplace
that will allow the insert to physically fit into the
firebox.Refertothe"MinimumFireplaceOpening"
section.
If the factory built fireplace* height is too low
for your Insert, you may remove the smoke
baffle plate and damper from the factory built
fireplace as long as these items are saved and
are reinstalled in the event that the Insert is
removed. NOTE: Any alterations made to the
listed solid fuel burning factory built fireplace
may void the listing of the fireplace. Cutting
anysheet-metalpartsofthefireplace,inwhich
the gas fireplace insert is to be installed, is
prohibited.
If the factory-built fireplace has no gas
access hole(s) provided, an access hole of
1.5" (37.5mm) or less may be drilled through
the lower sides or bottom of the firebox in a
proper workmanship like manner. This access
hole must be plugged with non-combustible
insulation after the gas supply line has been
installed.
The fireplace and fireplace chimney must
be clean and in good working order and
constructedof non-combustible materialsand
chimneycleanoutsmustfitproperly.Refractory,
glass doors, screen rails, screen mesh, and
log grates can be removed from the fireplace
beforeinstallingthegasfireplaceinsert.Smoke
shelves,shields and bafflesmaybe removed if
attached by mechanical fasteners. A tight seal
betweenthegasfireplaceinsertfluecollarand
thefireplacechimneymustbemadetoprevent
heat loss.
*Checkwithyourlocalinspectorbeforecommencing
with this installation.
BEFORE YOU START
Safe installation and operation of this appliance
requirescommonsense,however, wearerequired
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
General Safety Information
1) The appliance installation must conform
with local codes or in the absence of local
codes, with CAN/CSA B149.1 (in Canada)
or the National Fuel Gas Code ANSI Z223.1
NFPA 54 in the U.S.A. This appliance should
be installed by a qualified gas fitter technician
only.
2) Installation and repair should be done by a
qualified service person.
3) The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting,beddingmaterial,animalhair,etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.
4) See general construction and assembly
instructions. This appliance may only be
installedinavented,noncombustiblefireplace.
5) ThisapplianceisListedforbedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
6) Alwaysconnectthisappliancetoaventsystem
vent that is run (or routed) to the outside of the
buildingenvelope. Never vent to another room
or inside a building. Make sure that the vent
is properly sized and is of adequate height to
provide the proper draft.
7) Inspecttheventingsystemannuallyforblockage
and any signs of deterioration.
8) Any glass removed for servicing must be
replaced prior to operating the appliance.
9) WARNING: Failure to position the parts in
accordancewiththediagramsinthismanual
or failure to use only parts specifically
approved with this appliance may result in
property damage or personal injury.
10) To prevent injury, do not allow anyone who is
unfamiliarwiththeoperationtousethefireplace.
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace
into which the gas fireplace insert is installed.
"WARNING:Thisfireplacehasbeenconverted
for use with a gas fireplace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the fireplace re-approved by the authority
having jurisdiction."