Regulus PS2F 300 N+ User manual

www.regulus.cz
PS2F N+
PS2F N+
EN
Installation and Operation Manual
THERMAL STORES
PS2F 300 N+, PS2F 500 N+, PS2F 800 N+,
PS2F 1000 N+, PS2F 1500 N+ and PS2F 2000 N+

│2
CONTENTS
1 Description ..................................................................................................................................................... 3
1.1 Models ................................................................................................................................................ 3
1.2 Tank protection ................................................................................................................................... 3
1.3 Thermal insulation .............................................................................................................................. 3
1.4 Connection points on the tank ........................................................................................................... 3
1.5 Packaging .......................................................................................................................................... 3
2 General Information ....................................................................................................................................... 3
3 Technical Data and Dimensions ................................................................................................................... 4
4 Operation ........................................................................................................................................................ 5
5 Typical Layout Example with Thermal Store ............................................................................................... 5
6 Installation and Commissioning ................................................................................................................... 6
6.1 Connection to heat sources ............................................................................................................... 6
6.2 Connection to a solar thermal system ................................................................................................ 6
6.3 El. heating element installation .......................................................................................................... 6
6.4 Commissioning .................................................................................................................................. 6
7 Installing Insulation on the Tank .................................................................................................................. 6
8 Maintenance ................................................................................................................................................... 8
9 Disposal .......................................................................................................................................................... 8
10 Warranty .......................................................................................................................................................... 8

3 │
1 - Description
PS2F N+ Thermal Stores are intended for storing and subsequent distribution of thermal energy from solid-fuel red
boilers, heat pumps, solar collectors, electric boilers etc. This thermal store shall be always connected to a sealed
heating circuit with forced circulation. Thermal stores are tted with two anges; each can be tted with a suitably
sized tube heat exchanger depending on the selected application and required output. Mating anges for heat ex-
changers with either G 1” or G ¾” connections are supplied with PS2F N+ thermal stores. When no heat exchanger is
installed, a blind ange shall be used.
These heat exchangers are made of nned copper tubes that feature larger surface area and better heat transfer. The
lower heat exchanger usually connects to a solar thermal system and the upper one is used for DHW heating (contin-
uous) which limits signicantly the risk of Legionella bacteria formation. The tanks are also tted with nine G 6/4“ con-
nections to connect heat sources and heating system, four G ½“ ones for sensor sheaths and one G ½“ connection for
a safety valve. El. heating elements can be installed directly into the 6/4” connections.
1.1 - Models
Six models of 285, 479, 809, 932, 1509 and 2005 l capacity.
1.2 - Tank protection
The inner surface has no nish, no anticorrosion protection, the outer surface is lacquered in gray.
1.3 - Thermal insulation
Thermal insulation is available as a separate item. For easier handling, the insulation shall not be tted on the tank
until it reaches its denite place of installation. The insulation is made of eece, 100 mm thick, with a hard polystyrene
surface. It is closed by a quick lock.
1.4 - Connection points on the tank
2 anges with 210 mm inner diam.
8 side connections in a 90° sector, G 6/4” F thread
1 top connection, G 6/4” F thread
4 side connections for sensor sheaths, G ½” F thread
1 side connection for a 3 bar safety valve, G ½” F thread
1.5 - Packaging
Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap.
Included in the package are gaskets and bolts for the ange.
2 - General Information
This Owners Manual is an integral and important part of the product and must be handed over to the User. Read care-
fully the instructions in this Manual as they contain important information concerning safety, installation, operation and
maintenance. Keep this Manual for later reference. The appliance shall be installed by a qualied person according to
valid rules and Manufacturer‘s Instructions.
This appliance is designed to accumulate thermal energy of heating water and distribute it subsequently. It shall be
connected to a heating system and heat sources. The equipment is suitable also for continuous water heating. In such
a case, the customer needs to buy a suitably sized heat exchanger (available as accessory) and have it installed into
the upper ange.
Using the thermal store for other purposes than above described (e.g. as a DHW tank) is forbidden and the
manufacturer accepts no responsibility for damage caused by improper or wrong use.

│4
3 - Technical Data and Dimensions
Type - model PS2F 300 N+ PS2F 500 N+ PS2F 800 N+ PS2F 1000 N+ PS2F 1500 N+ PS2F 2000 N+
Tank code a14726 14729 15218 15221 15224 15227
Insulation code b19349 19347 19348 19340 19344 19351
Total uid volume in tank [l] c285 479 809 932 1509 20050
Empty weight [kg] d58 78 105 116 182 216
Tipping height without insulation [mm] V1 1430 1950 1895 2120 1965 2050
Dimensions [mm] ø D1 750 800 1000 1000 1300 1450
ø D 550 600 800 800 1100 1250
B1 1120 1615 1455 1690 1475 1510
B2 220 225 315 300 335 370
H1 1405 1915 1845 2080 1885 1955
H2 220 225 315 300 335 370
C1 1135 1630 1470 1705 1490 1525
C2 520 560 605 635 625 660
C3 830 1270 1155 1345 1175 1210
T895 1400 1250 1475 1270 1305
P450 450 530 525 550 585
U1 1120 1615 1455 1690 1475 1510
U2 360 435 515 510 535 570
U3 795 1155 1075 1230 1095 1130
U4 520 685 695 760 715 750
U5 880 1385 1235 1460 1255 1290
L1 1010 1515 1355 1590 1375 1410
L2 330 335 425 410 445 480
Dimensions
CONNECTIONS
pos. connection
Heat sources
B1 G 6/4" F
B2 G 6/4" F
Heating system
H1 G 6/4" F
H2 G 6/4" F
Control and safety
C1 G 1/2" F
C2 G 1/2" F
C3 G 1/2" F
TG 1/2" F
PG 1/2" F
Universal inlet / outlet
U1 G 6/4" F
U2 G 6/4" F
U3 G 6/4" F
U4 G 6/4" F
U5 G 6/4" F
Flanges
L1 12 x M12
L2 12 x M12
ØD1
ØD
H1
Tank code: ....................................................................................... a
Insulation code: ............................................................................... b
Total uid volume in tank: ................................................................ c
Max. working temperature in tank: .................................................. 95 °C
Max. working pressure in tank PS2F 300 N+ ÷ PS2F 1000 N+: ..... 4 bar
Max. working pressure in tank PS2F 1500 N+ ÷ PS2F 2000 N+: ... 3 bar
Empty weight: ................................................................................. d
Tipping height without insulation: .................................................... V1

5 │
4 - Operation
In the thermal store, heating water is heated up from several heat sources like various types of hot-water boilers,
renewable energy sources (heat pumps, solar collectors), or electric heating elements.
The thermal store shall be connected to a heat source through G 6/4” connecting ttings. Should it be connected to a
solar thermal system, too, this shall be done through a suitably sized heat exchanger installed into the lower ange.
5 - Typical Layout Example with Thermal Store
Example
Solar collectors, el. heating
elements and biomass-red
boiler.
KEY
1 – hot water storage tank
2 – el. heating element for DHW w. thermostat
3 – CSE SOL solar pump station
4 – three-way zone valve
5 – solar expansion vessel
6 – electric heating elements for heating system
7 – nned tube heat exchanger x.xx m2 in ange for DHW
8 – nned tube heat exchanger x.xx m2 in ange for solar
9 – thermal store for central heating - PS2F xxx N+ (N25)
10 – heating system expansion vessel
11 – boiler load unit - RGMAT
12 – biomass boiler (replace insert/stove)
13 – pump station for heating system - CSE2 MIX
14 – pump station for DHW heating – CSE OTS ZV
15 – solar collectors
16 – pump station for DHW recirculation – CSE TVMIX ZV
17 – safety kit for HW storage tank
18 – DHW expansion vessel
SV – cold water
TV – hot water
CV – hot water recirculation
ÚT – central heating (heating system)
KK – ball valve
ZV – check valve
AOV – automatic air vent valve
PTR – pressure temperature relief valve
REDV – pressure reducing valve (optional)
VK – drain valve
SVE – expansion vessel service valve
PV-ÚT – safety valve for heating system
MFB – Magnet Filterball
F – lter
BVTS – safety relief valve of boiler cooling loop
THERMOSTAT THERMOMETER
Other manuals for PS2F 300 N+
1
This manual suits for next models
5
Table of contents
Other Regulus Industrial Equipment manuals

Regulus
Regulus HSK PV Owner's manual

Regulus
Regulus HSK 350 K P-B User manual

Regulus
Regulus PSWF 300 N+ User manual

Regulus
Regulus PS 400 K+ User manual

Regulus
Regulus PS 500 E+ User manual

Regulus
Regulus RGMAT E G60 User manual

Regulus
Regulus BIO 55 MIX-BP G75 1F User manual

Regulus
Regulus PS 200 N+ User manual

Regulus
Regulus RGMAT E W-iPWM User manual