RelaDyne ThermoJet G5700 Series User manual

ThermoJetG5700 Series
Oil Purifier System
Installation and Operating Manual
______________________
5615 W Fuqua St. B-201 •Houston, Texas 77085
1-713.464.6266 •Fax: 713.464.9871
Doc 77740153 Rev 1
READ AND UNDERSTAND THIS OPERATING
MANUAL BEFORE ATTEMPTING TO INSTALL,
COMMISSION, OR USE THIS EQUIPMENT.
FAILURE TO UNDERSTAND THESE
INSTRUCTIONS COULD RESULT IN SERIOUS
PERSONAL INJURY AND OR LOSS OF
PROPERTY.
WARNING

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
2
of
90
NOTES:
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
_____________________________________________________________________________
_____________________________________________________________________________

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
3
of
90
Table of Contents
I GENERAL INFORMATION.......................................................................................................... 5
Manufacturer Contact Information ............................................................................................... 6
Explanation Of Graphic Symbols In The Documentation ............................................................ 7
II UNIT IDENTIFICATION AND LABELING .................................................................................. 10
ThermoJet ® Model G5700- Model Code Designations............................................................ 11
Model Code Designation Key .................................................................................................... 12
Tag Detail for ATEX Model Oil Purifiers .................................................................................... 13
Operating Conditions – ATEX Constructions............................................................................. 15
III DESCRIPTION OF THE PRODUCT......................................................................................... 16
Principal of Operation................................................................................................................. 17
Degasification............................................................................................................................. 17
Flow through the Unit................................................................................................................. 17
The Jet Mixer............................................................................................................................. 17
Return of Clean Oil..................................................................................................................... 17
MountingOptions ....................................................................................................................... 17
IV INSTALLATION......................................................................................................................... 18
Receipt Inspection ..................................................................................................................... 19
Placement of Equipment............................................................................................................ 19
Inlet and Return Oil Piping Connections.................................................................................... 20
Nitrogen Inlet Connection ......................................................................................................... 22
Condensate Purifier Connection................................................................................................ 23
System Exhaust and Relief Valve Connections......................................................................... 24
Electrical Power Connection...................................................................................................... 27
Grounding .................................................................................................................................. 30
V SYSTEM START-UP AND OPERATION .................................................................................. 31
Start-Up Procedures .................................................................................................................. 32
Heater Operation:....................................................................................................................... 37
Adjusting System Pressure........................................................................................................ 40
System Discharge Pressure ...................................................................................................... 41
Adjusting the Nitrogen Supply.................................................................................................... 42
System Vent Operation.............................................................................................................. 43
List of Gases Removed By ThermoJetG-3700E Series ........................................................ 45
Monitoring Normal Operation..................................................................................................... 46
Dailey ThermoJet Oil Purifier System Operational Checks....................................................... 46
System Shutdown...................................................................................................................... 47
VI ROUTINE MAINTENANCE....................................................................................................... 48
Maintenance Checks ................................................................................................................. 49
Oil Filter Maintenance................................................................................................................ 51
Y-Strainer Maintenance............................................................................................................. 52
Condensate Purifier Assembly Maintenance............................................................................. 53
VII CLEANING AND DECONTAMINATION.................................................................................. 54
Cleaning and Decontamination.................................................................................................. 55
Removal From Use, Disposal And Transport............................................................................ 57
Draining and Cleaning Procedures............................................................................................ 59
VIII TROUBLE SHOOTING........................................................................................................... 60
Trouble Shooting Guide............................................................................................................. 61
Quick Reference Troubleshooting Guide................................................................................... 64
Types of Product Misapplication and Misuse Not Covered By Warranty or Guarantees.......... 65
IX PARTS LIST / DRAWINGS / SCHEMATICS............................................................................ 66
Maintenance Spare Parts List.................................................................................................... 67
Process and Instrument Diagram .............................................................................................. 68

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
4
of
90
PID Symbol Legend and Customer Connection Chart.............................................................. 69
Electrical Wiring Diagram........................................................................................................... 70
Fuse Ratings and Characteristics.............................................................................................. 72
Tagging and Labeling ................................................................................................................ 73
Bill Of Materials.......................................................................................................................... 76
General Arrangement Drawings ................................................................................................ 79
Dimensional Outline Drawings................................................................................................... 84

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
5
of
90
I GENERAL INFORMATION

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
6
of
90
Manufacturer Contact Information
For additional information contact the manufacturing office nearest you or check
our website.
For questions regarding this publication or if you have specific questions
regarding the installation and operation of ThermoJet®Oil Purifier System,
please contact
Manufacturer
5615 W Fuqua St. B-201
Houston, Texas 77085
USA
Ph 1.713.464.6266
Fx 1.713.464.7375
MANUFACTURE
CLARUS | COT-PURITECH | LSC | LUBRITECH | SICELUB |
MANUFACTURER

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
7
of
90
Explanation Of Graphic Symbols In The Documentation
The following graphic symbols are used in this publication to communicate specific detailed
information necessary for the safe operation of this product. These graphic symbols are used to
create “Safety Alerts” within the documentation to alert the users of potential hazards, instruction
on how to avoid injury and instruction notices for safe operation. When interfacing with this
product it is important these safeguards are observed.
It is important for safety alerts to have the appropriate choice of signal word because this word
and its colored background communicate the severity of the hazard. The signal word calls
attention to the warning and designates a degree or level of hazard seriousness. The signal
words for product safety alerts as used in this manual are “DANGER”, "WARNING", "CAUTION",
and "NOTICE".
SYMBOL SYMBOL DESCRIPTION AND USE
This symbol is used to identify a “DANGER” level of hazard seriousness.
“DANGER” indicates a hazardous situation which, if not avoided, will result
in death or serious injury
WARNING
This symbol is used to identify a “WARNING” level of hazard seriousness.
“WARNING” indicates a hazardous situation which, if not avoided, could
result in death or serious injury
This symbol is used to identify a “CAUTION” level of hazard seriousness.
“CAUTION” indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury
This symbol is used to identify a “SAFETY ALERT” associated with either a
“WARNING” or “CAUTION” severity hazard. The alert is accompanied with
instruction necessary to avoid a hazard or personally injurious situation. The
“SAFETY ALERT” symbol is accompanied with other graphics to further
identify the type of hazard or personal injury risk involved.
This symbol is used to warn against risk of creating an “EXPLOSION”. This
symbol can be used in conjunction with a “SAFETY ALERT” symbol with
either a “DANGER”, or “WARNING” or “CAUTION” severity level.
This symbol is used to warn against “ELECTRIC SHOCK”. This symbol can
be used in conjunction with a “SAFETY ALERT” symbol with either a
“DANGER”, or “WARNING” or “CAUTION” severity level.
This symbol is used to warn against “CRUSHING”. The equipment should
never be tipped or stood on edge. This symbol can be used in conjunction
with a “SAFETY ALERT” symbol with either a “DANGER”, or “WARNING” or
“CAUTION” severity level.

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
8
of
90
SYMBOL SYMBOL DESCRIPTION AND USE
This symbol is used to warn against “SLIP HAZARDS”. This symbol can be
used in conjunction with a “SAFETY ALERT” symbol with either a
“DANGER”, or “WARNING” or “CAUTION” severity level.
This symbol is used to warn against “SUDDEN PRESSURE RELEASE” of
compressed gas. This symbol can be used in conjunction with a “SAFETY
ALERT” symbol with either a “DANGER”, or “WARNING” or “CAUTION”
severity level.
This symbol is used to warn against “CORROSIVE” or “CAUSTIC
CHEMICALS” that might inadvertently be used to clean the equipment. Any
cleaning agents used must be compatible with the equipment materials of
construction and not harmful to personnel. This symbol can be used in
conjunction with a “SAFETY ALERT” symbol with either a “DANGER”, or
“WARNING” or “CAUTION” severity level.
This symbol is used to indicate that a “FORK TRUCK” is used to transport
the equipment. The Fork truck operator should be properly trained in its
operation and observe all plant driving and safety regulations. Do not
transport equipment on public roadways using a fork truck. This symbol can
be used in conjunction with a “SAFETY ALERT” symbol with either a
“DANGER”, or “WARNING” or “CAUTION” severity level.
This symbol is used to warn against the presence of poisonous substances
being present. This symbol can be used in conjunction with either a
“DANGER”, or “WARNING” or “CAUTION” severity level
This symbol is used to warn against the presence of a carcinogenic
substances being present. This symbol can be used in conjunction with
either a “DANGER”, or “WARNING” or “CAUTION” severity level
This symbol is used to warn against the presence of a hot surfaces. This
symbol can be used in conjunction with either a “DANGER”, or “WARNING”
or “CAUTION” severity level
This symbol is used to identify “NOTICE” instructions and is used where a
"SAFETY ALERT" designation is too severe. A “NOTICE” label is used for
instruction or issuing a reminder about a condition which is more procedural
in nature rather than related to an immediate risk of personal injury.
This symbol is used to indicate that gloves and other “PERSONAL
PROTECTIVE EQUIPMENT (PPE)” should be used. This symbol may be
used in conjunction with a “NOTICE”.

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
9
of
90
SYMBOL SYMBOL DESCRIPTION AND USE
This symbol is used to indicate that eye protection and other “PERSONAL
PROTECTIVE EQUIPMENT (PPE)” should be used. This symbol may be
used in conjunction with a “NOTICE”.
This symbol is used to indicate that respiratory protection and other
“PERSONAL PROTECTIVE EQUIPMENT (PPE)” should be used. This
symbol may be used in conjunction with a “NOTICE”.
This symbol is used to indicate that lifting points are provided on equipment
for safe movement and should be used. This symbol may be used in
conjunction with a “NOTICE” or “CAUTION” severity level.
This symbol is used to indicate that the reader must read and understand
referenced “DATA AND INFORMATION”. This symbol may be used in
conjunction with a “NOTICE” or with a “SAFETY ALERT” symbol with either
a “DANGER”, or “WARNING” or “CAUTION” severity level.
This symbol is used to advise “SPILLS” are to be controlled and cleaned up.
In case of spillage, the user or other responsible body must ensure
appropriate cleanup and decontamination is carried out. This symbol may be
used in conjunction with a “NOTICE” or with a “SAFETY ALERT” symbol
with either a “DANGER”, or “WARNING” or “CAUTION” severity level.
This symbol is used to encourage the use of cleaning materials which the
customer can “RECYCLE”. Drained oil should be recycled. This symbol may
be used in conjunction with a “NOTICE”.
This symbol is used to advise the materials must be disposed of in
accordance to environmental laws ordinances and directives. Disposal
methods which have “ADVERSE ENVIRONMENTAL IMPACT” are to be
avoided. This symbol may be used in conjunction with a “NOTICE”.

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
10
of
90
II UNIT IDENTIFICATION AND LABELING

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
11
of
90
ThermoJet ® Model G5700- Model Code Designations
•Electrical Standard:
The ThermoJet ® Model G5700 Oil Purifier is designed to comply with
ATEX II 3G Ex dn IIB+H2 T3
•Inlet Power:
The LubriMist® Model is available for connection to either 380, 415 or 460 VAC three-phase
power. The purchaser specifies supply voltage. Refer to the model code sheet for options
available for specific voltages and construction.
•Mounting:
Designates the mounting method used.
EXPLOSION HAZARD – Substitution of
components may impair suitability for
II 3G Ex dn IIB+H2 T3
WARNING

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
12
of
90
Model Code Designation Key
ThermoJet ® Model G5700
Oil Purifier
Option Description Option
Code Description
Application Type
Electrical Area
Classification
H2700
De-watering application in the
Hydrocarbon Processing Industry
ATEX Certified. Zone 2 IIB+H2 T3
22" X 30" footprint
G3700
Degassing Application in
Hydrocarbon Processing Industry
ATEX Certified. Zone 2 IIB+H2 T3
22" X 30" footprint
H4700
De-watering application in the
Hydrocarbon Processing Industry
ATEX Certified. Zone 2 IIB+H2 T3
36" X 48" footprint
G5700
Degassing Application in
Hydrocarbon Processing Industry
ATEX Certified. Zone 2 IIB+H2 T3
36" X 48" footprint
Heater Type E Electric Heater
A 460 VAC, 60 Hz, 3 Phase
B
380 VAC, 60 Hz, 3 Phase
E 380 VAC, 50 Hz, 3 Phase
K 415 VAC, 50 Hz, 3 Phase
Heater Type BL Base mounted with feet and lifting eyes
FL
Fork-liftable
Export Crating
(excluding North
America, South
America & Canada)
Export Crating

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
13
of
90
Tag Detail for ATEX Model Oil Purifiers
ThermoJet ® Oil Purifiers manufactured compliant with the ATEX Directive
Data Ref.
Description
Example
Model No.
Per Customer. P.O. & Manufacture Job Order
See ” ThermoJet ® Oil Purifier Model Code Designation Key”____________________
G5700-EEBL
Serial No.
Unique Serial Numbers are to be issued to each machinery item. The equipment Serial Number
is a unique sequential number selected and logged in an EXCEL file . The serial number log is
managed and maintained by the Manufacture QC Department.
TJ-XXXX
Volts AC
Machinery is available for connection to either 380 VAC, 415 VAC or 460 VAC electrical power.
Purchaser specifies the electrical power requirement. Reference ” ThermoJet ® Oil Purifier
Model Code Designation Key”
Option Code B or E 380 VAC power______________________
Option Code K 415 VAC power______________________
Option Code A 460 VAC power______________________
380 VAC
415 VAC
460 VAC
HZ
Machinery is suitable for 50 or 60 hertz AC power as stipulated by the “POWER” option of the
”ThermoJet ® Oil Purifier Model Code Designation Key”
Power Option Code A 460 VAC 60 Hz______________
Power Option Code B 380 VAC 60 Hz ______________
Power Option Code E 380 VAC 50 Hz ______________
Power Option Code K 415 VAC 50 Hz ______________
60 Hz
60 Hz
50 Hz
50 Hz
Power
Maximum operating power requirement at the specified voltage with the power selector switch
in the “ON” position with the electric motor running and the oil heater fully energized. Reference
” ThermoJet ® Oil Purifier Model Code Designation Key”
Power Option Code A 460 VAC 60 Hz______________
Power Option Code B 380 VAC 60 Hz ______________
Power Option Code E 380 VAC 50 Hz ______________
Power Option Code K 415 VAC 50 Hz ______________
38 KW / 48.9 Amps
38 KW / 60.3 Amps
38 KW / 60.3 Amps
38 KW / 55.2 Amps
YOM
Year Of Manufacture
YYYY

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
14
of
90

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
15
of
90
Operating Conditions – ATEX Constructions
•Indoor/outdoor Use
•Ambient temperature range
o -20°C to +50°C (-4°F to +122°F) Standard Construction
•Altitude to 2000m
•Relative humidity not exceeding 95%
•Power supply fluctuations not to exceed ±10% rated voltage.
•Over voltage category II IEC 60364-4-443
•Pollution degree 2
•IP 54

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
16
of
90
III DESCRIPTION OF THE PRODUCT

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
17
of
90
Principal of Operation
The ThermoJet Oil Purifier works on the principal of air stripping. The use of air or nitrogen
bubbled through contaminated liquids has long been used to remove contaminants. But the
use of this technique was restricted because the volume of gas required was large due to
limited mixing of the gas with the liquid. The unique technology embodied by the ThermoJet
makes air/gas stripping practical and efficient because of the mixing and intimate contact of
the air/gas with the fluid being cleaned. In addition, the ThermoJet utilizes the principal that
the capacity of a gas to entrain moisture increases exponentially with temperature.
The ThermoJet is designed to operate on ISO 32 through ISO 220 oils from circulating oil
systems. Oil with higher viscosity (ISO 150 and ISO 220) must be at 40oC (100oF) minimum
temperature at the inlet to the ThermoJet during start-up.
Degasification
The ThermoJet® removes dissolved light hydrocarbon gases such as propane and H2S from
industrial lubricants. In refineries and petrochemical plants an ideal application for the
ThermoJet is the removal of hydrogen sulfide from compressor seal oil. The ThermoJet
returns
the viscosity of the lube oil and restores the oil flash point to like new levels. No longer is there
a need to dispose of gas laden and sour lube oils; these oils can be purified and reused.
Flow through the Unit
The suction pump of the ThermoJet draws contaminated oil from the user lube, seal or
hydraulic system. Flexible hose or hard piping can be used to connect the ThermoJet to the
system reservoir. A one and one half horsepower motor drives the suction pump. The suction
pump is protected by a “Y” strainer. From the pump the oil passes through a filter. This
cartridge filter can be easily replaced. It is recommended replacement be made when the
pressure differential across it, as monitored by two easily read gages which are externally
mounted on the panel above the access door, reaches 2 BAR ( 30 PSI). From the filter the
oil passes through the heater that elevates the oil to 82° C (180° F).
The electric heater temperature is set and controlled with a solid-state device whose
operation is viewed through a window on the electrical control box. After the heater, the oil
passes through the heart of the ThermoJet
which is the dual stage jet mixer
The Jet Mixer
This proprietary and uniquely designed device is the heart of the system. Without the aid of
secondary pressure, it continuously and automatically draws ambient air or inert gas such as
nitrogen into the heated oil stream as delivered to it by the inlet pump. The ambient air/gas
becomes intimately mixed with the oil and assumes the temperature of the oil. The oil leaves the
Jet Mixer and is directed to the separation vessel that operates at atmospheric pressure. Here
the moisture laden air, or gas saturated nitrogen, expands and leaves the oil thus cleansing
the oil of water or dissolved hydrocarbon gases.
Return of Clean Oil
In the separation vessel the oil from the jet mixer cascades down trays to promote the release
of the saturated air/gas. A volume of oil is maintained in the lower portion of the separation
vessel to allow any entrained air to leave the oil so that none is contained in the return oil
stream. The second close coupled pump driven by the electric motor returns oil to the user
reservoir. Water vapor vents from the separation vessel and travels through a filter and oil
absorbing media to insure that discharge from the unit is oil free. The water condensate
discharged from the ThermoJet can be piped to a sanitary sewer.
MountingOptions
The ThermoJet Model G5700 Oil Purifier is offered in two different mounting configurations so
that the unit can best fit client requirements. All series units are available as base mounted with
lifting eyes. The H-2000 series is also available mounted on a fork lift able base.

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
18
of
90
IV INSTALLATION
All ATEX approved constructions must be
installed in accordance with the requirements of
EN60079-14:2014 – Part 14 Electrical installations
in hazardous areas (other than mines).
WARNING
THIS INSTRUMENT MUST BE EARTHED
WARNING
If the equipment is not used in the manner
described in this manual the protection provided
by the equipment may be impaired
WARNING

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
19
of
90
Receipt Inspection
Remove all shipping materials and plastic plugs.
Inspect for shipping damage externally and internally (open enclosure door), and report any found
to the manufacturer immediately. It is desirable to take photographs of any damage to
substantiate your claim.
Inspect for completeness of materials and equipment against the packing list and the purchase
order.
Placement of Equipment
After verifying the adequacy and strength of all relevant support surfaces, place the ThermoJet
Oil Purifier as close as possible to the oil reservoir in an upright position. See Dimensional
Drawings in the PARTS LIST / DRAWINGS / SCHEMATICS section of this manual for anchor
bolt and equipment clearance dimensions
The ThermoJet Oil Purifier is constructed with lift rings. Ensure that lifting equipment and rigging
is suitable for safely lifting, moving and placing the equipment.
Using standard plant practices secure the ThermoJet Oil Purifier to the installation surface by
bolting the four (4) mounting feet.
NOTICE:
Be sure to leave working space around the system and consider
space requirements for electric heater removal, fully opened access
door, control panel enclosure door, and gauge monitoring.
Do not tip or stand equipment on edge
WARNING
Use suitable transport equipment for lifting and
setting the equipment into place. Ensure that the
equipment is secured prior to and during lifting
and transport. Stand clear of the all equipment
while being maneuvered. Crane and fork truck
operators should be properly trained in there
operation.

THERMOJET®G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc # 77740153
Rev 1
Date June 2020
Page
20
of
90
Inlet and Return Oil Piping Connections
The oil inlet and outlet connection sizes are 1-1/2” NPT and 1” FNPT respectively. The user
suction and discharge line sizes (either schedule 40 pipe or smooth I.D. hose) should be DIN 25 /
1” I.D. minimum and DIN 50 / 2” I.D. maximum to ensure that no flow restrictions will occur due to
line lengths, high viscosity, etc. When processing high viscosity oils, the larger sizes of pipe or
hose should be used. If tubing is used, increase the diameter by at least one size. All
connections should be tight and free of air leaks.
If a flooded suction to the ThermoJet Oil Purifier is not practical, ensure that the suction height
from the reservoir drain to the inlet connection of the ThermoJetis no more than 8 feet (2.4
meters) above the minimum oil level in the reservoir.
If the suction lift exceeds 8 feet (2.4 meters), install a foot-valve or foot-pump to ensure that the
suction pump will prime and hold prime during long-term service.
NOTICE:
Even very small air leaks can dramatically affect pump suction
performance. If air bubbles are visible in the sight glass after flow is
established, re-tighten all suction connection points.
This manual suits for next models
4
Table of contents
Other RelaDyne Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

SCHUNK
SCHUNK SVP-4 Assembly and operating manual

HEIDENHAIN
HEIDENHAIN EIB 2391S operating instructions

Sullair
Sullair 65 II Use and Maintenance Spare Parts List

ABB
ABB Power2 845-M46 Operation manual

PCB Piezotronics
PCB Piezotronics 352C43 Installation and operating manual

Eaton
Eaton DILM32-X L Series Instruction leaflet