Please read these Operational and Installation Guidelines before installing the SmoothFlo®
Series Pumps. If additional help is needed, please consult the Factory.
CAUTIONS
yWater pipe connections and fixtures directly connected to a potable water supply shall
be sized, installed and maintained in accordance with Federal, State, and local codes.
yDo not operate the pump above the pressure limitations specified on the data label.
yNever operate the pump in a harsh environment or hazardous atmosphere, since
motor brush and switch may cause electrical arcing.
yDo not pump gasoline or other flammable liquids. Do not use with petroleum
products.
yDo not assume fluid compatibility. If the fluid is improperly matched to the
pumps’ elastomers, a leak may occur
yAs long as there is inlet water pressure, the pump will not stop forward flow of water
even if the motor is turned o. Be sure the system has positive means of shutting o
water supply.
yAlways consider electrical shock hazard when working with and handling electrical
equipment. If uncertain, consult an Electrician. Electrical wiring should only be done
by a qualified Electrician per Local and State Electrical Codes.
MOUNTING
yThe pump should be mounted in a dry place and away from any source of heat. If
an enclosure is used, special instructions for cooling the motor may be necessary.
Consult the Factory.
yDo not subject the pump to extreme high or low (freezing) temperatures while in
operation. (Operating ambient temperature range is 32ºF to 115ºF).
yThe pump may be mounted horizontally with the outlet port on the right when viewed
from the pump end or with the pump above the mount; or vertically with the pump
above or below the motor.
PLUMBING
yThe pump is equipped with either a pressure sensing demand switch, a bypass relief
valve, or both which controls the maximum safe operating pressure.
yWe recommend use of flexible tubing with proper pressure rating.
yPump will prime only if all pressure is relieved from outlet port.
yIt is recommended that debris-free liquid be pumped or an in-line sediment filter (50
mesh) be installed at the inlet side to keep foreign debris out of the system.
yThe pump should always be mounted prior to any components which could introduce
particles to the liquid; thus, preventing them from entering the pump chambers and
possibly causing clogging.
yAvoid any sharp bends which may crimp tubing and restrict flow. Use 90º elbow
fittings if necessary. REMCO provides pumps with dierent kinds of fittings. Please
consult Factory for your needs.
ELECTRICAL
yThe SmoothFlo® Series Pumps are designed for intermittent duty, but may run
continuously if the motor temperature does not exceed the recommended limit. Some
SmoothFlo® Series Pumps are equipped with thermally protected motors and in case
motor temperature exceeds thermal cut-out rating, pump will shut down and will not
restart until motor cools down to specified temperature. Please consult the appropri-
ate Data Sheet for continuous running parameters, noting the eect of rapid On/O
Cycling. (See section below)
yIf a power supply is used with the system and the supply is not furnished by
REMCO, it will need to be reviewed for correct application and approval by REMCO.
Installation Procedure
The basic demand pump is controlled by a built-in pressure sensing demand switch. When
a faucet or valve is opened down stream of the pump, line pressure drops, thus starting the
pump automatically. Conversely, when the valve shuts, the line pressure increases turning
the pump o automatically. The pressure switch actuates in response to the pump outlet
pressure at a predetermined and preset pressure. The pump label indicates the pre-set OFF
pressures. Typically, the OFF pressure is accurately set at the FACTORY and the ON pressure
is within an allowable range below that value. In response to the characteristics of the
system in which the pump is installed, such as the flexibility and length of the tubing, and
the faucet or valves and the duration that they are open, these pressure settings may vary.
Therefore, change in pressure settings is expected with use and over time. If the pump does
not have an integral pressure sensing demand switch (i.e. pump is operated with an external
control), pump will be equipped with a bypass relief valve (bypass is factory preset).
Read the OPERATIONAL AND INSTALLATION GUIDELINES on the other side carefully
before starting to install the pump. Consult the Factory if there is any question.
Determine the optimum location for your pump before proceeding.
yTurn o the fluid supply.
yCut the flexible tubing in suicient length to avoid any stress on the tubing or hose
where it connects to the pump or the fitting on any accessory or hose.
yInsert tubing/hose into pump ports. If compression fittings with threaded nuts are
used, insert tubing until it bottoms out in the port, hand tighten the compression nut
until the connection is tight. Then use a wrench to tighten the nut 1/2 turn clockwise or
follow the wrench tightening instructions provided by the fitting manufacturer.
yThe SmoothFlo® Series pump is now ready for operation. Open the inlet valve if any to
allow fluid to flow to the pump.
yIf the power source is a transformer, plug the appropriate REMCO
supplied or approved transformer into the receptacle and connect the pump to the
transformer. If the power source is not a transformer,
connect the pump to the appropriate power source. Open the discharge or
dispensing valve. Allow water to circulate, purging any entrapped air.
yThe pump will now start building pressure. Operating pressure will vary with flow rate,
flow valve, feed-water pressure and line voltage. Check for fitting leaks.
yIf compression fittings with threaded nuts are used, observe any leaks after pump has
run for approximately 15 minutes. Further tighten
compression nuts approximately 1/8 to 1/4 of a turn on all fittings in the system. Wait 15
minutes and repeat the leak check.
NOTE: Further adjustments should not be necessary although it may take several
days of operation before all the air has been purged and the system is stabilized.
yRapid On/O Cycling must be limited to no more than 6 times per minute,
even if the pump is operating in the Continuous Duty zone. Cycling could
cause the motor to heat beyond the recommended maximum temperature,
and reduce the operational life of the pump and pressure-sensing switch.
Servicing
EVERY USE
Run clean water through the pump and
system.
EVERY YEAR
Check system against operating standards.
If continuous duty, replace lower housing
assembly
EVERY OTHER YEAR
Check against operating standards. If
continuous duty, replace motor
EVERY FIFTH YEAR
Replace pumphead
www.remcoindustries.com SmoothFlo Manual - 2022
SMOOTHFLO® SERIES PUMPS
Operational and Installation Guidelines
Troubleshooting Guidelines (Contact Remco for troubleshooting)
IF PUMP WILL NOT START CHECK:
yCorrect voltage (±10%) and electrical connections
yFuse or breaker
yPressure switch operation and correct voltage at switch
yRectifier or motor for open or grounded circuit
IF PUMP WILL NOT PRIME (NO DISCHARGE WITH MOTOR RUNNING) CHECK:
yDebris in strainer
yRestriction (kinks) in inlet/outlet tubes
yDebris in inlet/outlet
yAir leaking in from inlet
IF PUMP WILL NOT SHUT OFF (OUTPUT LINE CLOSED AND NO LEADS) CHECK:
yAir trapped in outlet line or pump head
yCorrect voltage to pump
yDebris in pump inlet/outlet valves
yLoose drive assembly or pump head screws
yPressure switch operations/adjustments
yLeaks
IF PUMP LEAKS FROM PUMP HEAD OR SWITCH CHECK:
yLoose screws at switch or pump head
ySwitch diaphragm ruptured or pinched
yPunctured diaphragm if fluid is present
Warranty
REMCO warrants its products to be free from defects in material and workmanship on all products
sold by REMCO for resale or for use in purchasers’ own business or original equipment
manufacturer. Under normal use, maintenance, and service (rental use excluded), the following
terms apply: For REMCO SmoothFlo® products, the warranty will last for a period of 90 days for
commercial use from the date of purchase by the user. This warranty applies to the original purchaser
of the equipment and is non-transferrable. Verification of the purchase is the responsibility of the
buyer. REMCO’s obligation under this warranty shall be limited to replacing or repairing at REMCO’s
discretion, any such product or part which must be returned to REMCO’s factory with a Return Material
Authorization Number (RMA), transportation charges approved by REMCO or prepaid, and which
upon examination, is found to REMCO’s satisfaction to have been defective under the terms of this
warranty. No credit will be allowed against future purchases for items returned as defective under the
terms of REMCO’s warranty. This warranty does not extend to any products, which have been altered
or modified outside the REMCO factory, to any products that have not been properly maintained, nor
does it apply to units that are returned in an unassembled condition. Furthermore, the warranty does
not extend to pumps that are non-compliant with REMCO’s Engineering Standards. This includes,
but is not limited to, pumps ordered without an integral pressure control mechanism. The warranty
guarantees that products will perform to REMCO’s flow and pressure specifications throughout the
life of the warranty. The warranty does not cover wear, appearance, misuse, abuse, misapplication or
external water damage. If the returned product is found not to be defective under the conditions of this
warranty, a charge will be made for repair or replacement of the product.
Brush wear may be limited to 1000 hours or less.
This is a Limited Warranty. It covers the product only and the extent of the coverage is limited to the
cost of the product. As the manufacturer has no control over shipping, handling and
installation, the warranty cannot cover water damage, or any other damage, caused by a leak or other
malfunction.
THIS WARRANTY IS IN LIEU OF ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING IMPLIED
WARRANTIES OR WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE.
NO PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR ASSUME OBLIGATION OR LIABILITY
ON REMCO’S BEHALF. REMCO SHALL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE OR
CONSEQUENTIAL DAMAGES OF ANY KIND INCURRED BY THE REASON OF THE USE OR SALE OF ANY
DEFECTIVE PRODUCT AND PART. THIS WARRANTY SHALL BE GOVERNED BY THE LAWS OF THE STATE OF
MINNESOTA, WITH ANY DISPUTE OR CLAIM VENUED OR HEARD IN THE STATE OF MINNESOTA.
Replacement Parts
1
www.remcoindustries.com SmoothFlo Manual - 2022
1
PART NUMBER GPM DESCRIPTION
5917-9I77 5.3 GPM SmoothFlo Series, 100 PSI, 3/4” Quick Attach
5918-9I77 7.0 GPM SmoothFlo Series, 100 PSI, 3/4” Quick Attach
Complete Pumphead Assembly
*When being used in soft wash applications, SmoothFlo pumps need to be flushed with clean water at the of the day*

Other Remco Water Pump manuals

Remco 3200 SERIES Quick start guide

Remco

Remco 3200 SERIES Quick start guide

Remco AQUAJET Series Instruction sheet

Remco

Remco AQUAJET Series Instruction sheet

Remco LP-BK01 Configuration guide

Remco

Remco LP-BK01 Configuration guide

Remco PROFLO 3300 Quick start guide

Remco

Remco PROFLO 3300 Quick start guide

Remco 55AQUAJET-AES Quick start guide

Remco

Remco 55AQUAJET-AES Quick start guide

Popular Water Pump manuals by other brands

salmson SXS Installation and starting instructions

salmson

salmson SXS Installation and starting instructions

Zoeller 350 instruction manual

Zoeller

Zoeller 350 instruction manual

Wolf ZP-3 installation instructions

Wolf

Wolf ZP-3 installation instructions

Cobalt Aquatics E-X-T 800 Instructions and warranty

Cobalt Aquatics

Cobalt Aquatics E-X-T 800 Instructions and warranty

Silverline 633872 user manual

Silverline

Silverline 633872 user manual

Graco ToughTek S340e Operation, repair, and parts

Graco

Graco ToughTek S340e Operation, repair, and parts

Seepex BW 10 Operating and maintenance instructions

Seepex

Seepex BW 10 Operating and maintenance instructions

DAB DAB E.SYBOX Instruction for installation and maintenance

DAB

DAB DAB E.SYBOX Instruction for installation and maintenance

BUSCH COBRA BC 1001 G instruction manual

BUSCH

BUSCH COBRA BC 1001 G instruction manual

Eaton 70523 Parts and Repair Information

Eaton

Eaton 70523 Parts and Repair Information

Marina 75 instruction manual

Marina

Marina 75 instruction manual

STA-RITE DB10018T-02 owner's manual

STA-RITE

STA-RITE DB10018T-02 owner's manual

Pompco PJC owner's manual

Pompco

Pompco PJC owner's manual

Flotec FPZT7300 owner's manual

Flotec

Flotec FPZT7300 owner's manual

Grundfos KPC 24/7 210 instructions

Grundfos

Grundfos KPC 24/7 210 instructions

Bestway Sidewinder 62097 operating instructions

Bestway

Bestway Sidewinder 62097 operating instructions

GORMAN-RUPP PUMPS 81 1/2B2-B Installation, operation, and maintenance manual with parts list

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS 81 1/2B2-B Installation, operation, and maintenance manual with parts list

Barnes 30MU Installation and operation manual

Barnes

Barnes 30MU Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.