REMKO Smart-Com SC-1 User manual

Operating and
installation instructions
Read the instructions prior to performing any task!
REMKO SC-1 Smart-Com
For the room air conditioner BL, ML, MVV, MXD, MXT, MXW,
0335-2023-02 Edition 1, en_GB
Manual for experienced specialists
RVD, RVT, RWT and RXT

Translation of the original
Read these operating instructions carefully before commis-
sioning / using this device!
These instructions are an integral part of the system and must
always be kept near or on the device.
Subject to modifications; No liability accepted for errors or mis-
prints!

Table of contents
1 Safety and usage instructions............................................................................................................. 4
1.1 General safety notes....................................................................................................................... 4
1.2 Identification of notes...................................................................................................................... 4
1.3 Personnel qualifications.................................................................................................................. 4
1.4 Dangers of failure to observe the safety notes................................................................................ 4
1.5 Safety-conscious working............................................................................................................... 4
1.6 Safety notes for the operator........................................................................................................... 5
1.7 Safety notes for installation, maintenance and inspection.............................................................. 5
1.8 Unauthorised modification and changes......................................................................................... 5
1.9 Intended use................................................................................................................................... 5
1.10 Warranty........................................................................................................................................ 5
1.11 Transportation and packaging....................................................................................................... 6
1.12 Environmental protection and recycling........................................................................................ 6
2 Technical data and scope of delivery.................................................................................................. 7
2.1 Unit data.......................................................................................................................................... 7
2.2 Unit dimensions............................................................................................................................... 7
2.3 Scope of delivery............................................................................................................................. 7
3 Operation............................................................................................................................................... 8
3.1 General operation........................................................................................................................... 8
3.2 External access via REMKO Smart Web...................................................................................... 12
3.3 Activating KNX programming mode ............................................................................................. 14
4 Electrical wiring and interfaces......................................................................................................... 15
4.1 Connections and interfaces........................................................................................................... 15
4.2 Electrical wiring for the air conditioning units................................................................................ 16
4.3 Electrical wiring to the KNX network............................................................................................. 19
5 Assembly and installation.................................................................................................................. 22
6Commissioning................................................................................................................................... 25
7 Compatibility....................................................................................................................................... 25
8 KNX communication objects............................................................................................................. 26
9 Index..................................................................................................................................................... 27
3

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units for the first time. It contains
useful tips and notes such as hazard warnings to
prevent personal injury and material damage.
Failure to follow the directions in this manual not
only presents a danger to people, the environment
and the system itself, but will void any claims for
liability.
Keep this operating manual and the refrigerant
data sheet near to the units.
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
REMKO SC-1 Smart-Com
4

1.6 Safety notes for the operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nProtective covers (grille) over moving parts
must not be removed from units that are in
operation.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with certain unit parts or components
may lead to burns or injury.
nThe units and components must not be
exposed to any mechanical load, extreme
levels of humidity or extreme temperature.
nSpaces in which refrigerant can leak sufficient
to load and vent. Otherwise there is danger of
suffocation.
nAll housing parts and device openings, e.g. air
inlets and outlets, must be free from foreign
objects, fluids or gases.
nThe units must be inspected by a service tech-
nician at least once annually. Visual inspec-
tions and cleaning may be performed by the
operator when the units are disconnected from
the mains.
1.7 Safety notes for installation,
maintenance and inspection
nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nLocal regulations and laws such as Water
Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nUnits may only be mounted at the points pro-
vided for this purpose at the factory. The units
may only be secured or mounted on stable
structures, walls or floors.
nMobile units must be set up securely on suit-
able surfaces and in an upright position. Sta-
tionary units must be permanently installed for
operation.
nThe units and components should not be oper-
ated in areas where there is a heightened risk
of damage. Observe the minimum clearances.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices must not be altered or
bypassed.
1.8 Unauthorised modification
and changes
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufactured ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
The unit is used to operate indoor units from a
remote location.
Any different or additional use is a non-intended
use. The manufacturer/supplier assumes no lia-
bility for damages arising from non-intended use.
The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
5

1.11 Transportation and
packaging
The units are shipped in sturdy transport pack-
aging. Immediately check the units on delivery and
make a note of any damage or missing parts on
the delivery note. Inform the forwarding agent and
contractual partner. Claims under guarantee made
at a later date will not be accepted.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
1.12 Environmental protection
and recycling
Disposal of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposal of equipment and components
Only recyclable materials are used in the manufac-
ture of the devices and components. Help protect
the environment by ensuring that the devices or
components (for example batteries) are not dis-
posed in household waste, but only in accordance
with local regulations and in an environmentally
safe manner, e.g. using certified firms and recy-
cling specialists or at collection points.
REMKO SC-1 Smart-Com
6

2 Technical data and scope of delivery
2.1 Unit data
Series Smart Control Touch
Operating mode Remote control
Power supply V +12 V DC
Enclosure class IP 30
Max. power consumption W 12
Max. cable length m 150
Recommended cable type (connecting line) mm2sheathed, min. 0.5 2
Environment
Ambient temperature °C 0-70
Air humidity % rH 0-95 (relative) non-condensing
Remote control EDP no. 1613264
WLAN stick EDP no. 1121589
We reserve the right to make technical changes for the purpose of technical advancement.
2.2 Unit dimensions
151
151
80 24 11
Fig. 1: Unit dimensions (all measurements in mm)
We reserve the right to modify the dimensions and
design as part of the ongoing technical develop-
ment process
2.3 Scope of delivery
3
2
1
4
Fig. 2: Scope of delivery
Scope of delivery
1 Control element
2 Surface-mounted housing
3 Power supply unit with Euro plug
4 120 Ohm resistor
7

3 Operation
3.1 General operation
The REMKO Smart Control Touch regulation is an
operating module with touch display. No buttons
are required to adjust and change parameters.
Instead, this takes place by touching the surface of
the controller at the appropriate points.
1 2 3 4
Fig. 3: Basic controls
The control panels for the four basic controls are
always displayed at the bottom of the screen. This
enables fast and intuitive navigation through the
basic menus.
1
Overview
Fig. 4: Overview
The overview display shows information such as
the current outside temperature, as well as the cur-
rent room actual and target temperatures when
connected to the internet. The tiles can be used to
make further settings. The selection of tiles to be
displayed in the overview display can be set indi-
vidually.
The “Operating mode” tile can be used to query
and set the system operating state. The following
operating modes are available for selection:
Off:
All indoor units are switched off.
Cooling:
All indoor units receive the one-off command
"Cooling" mode.
Dehumidification:
All indoor units receive the one-off command
"Dehumidification" mode.
Heating:
All indoor units receive the one-off command
"Heating" mode.
Recirculation:
You can operate the weather display to can call up
the weather forecast for the system location for the
next 24 hours.
The indicators on the LCD and division shown
in these instructions are subject to further con-
tinuous, technical and visual development.
Therefore, there may be some differences to
the actual indicators on the LCD.
"Information" basic menu
The operating parameters of the connected indoor
units can be read via this menu. Changes to unit
settings are not possible here!
Fig. 5: Information
REMKO SC-1 Smart-Com
8

The information displayed varies depending on
the authorisation level (user/expert level). If
several indoor units have been combined as a
group, they are still displayed individually in this
overview in order to query them individually.
"Settings" basic menu
The operating parameters of the connected indoor
units can be set via this menu. The connected
indoor units are clearly listed in the unit list with the
respective assigned address.
Fig. 6: Settings
The designation of the indoor units can only be
changed via the Smart Web Portal. To do so,
select the "Edit" menu item in the "Unit over-
view"
Fig. 7: "Edit" menu item
In the upper area, you will find the "Rename indoor
units" menu item.
Fig. 8: Rename indoor units
The various settings can be made by selecting the
respective indoor unit.
The settings are preset individually for each
indoor unit. These settings are the basis for
selecting the operating mode in the "Overview"
menu. Example: If the status of the respective
indoor unit is set to "OFF", this unit will not
switch on even if "Automatic" operating mode
was selected in the overview. To do this, the
indoor unit must be set to "On"
Status:
The respective indoor unit is switched on or off
individually here.
Operating mode:
If the overall operating mode is "Manual", cooling,
heating, recirculation and dehumidification are
available here. If the overall operating mode is
"Automatic", the operating mode of the respective
indoor unit changes automatically depending on
the outdoor temperature.
Room target temperature:
The desired room temperature is set here in the
range "17 to 30°C".
Fan speed:
Select from "Automatic", "Low", "Medium" and
"High". In "Automatic" operating mode, the air
volume flow is adapted to the currently required
unit output.
Swing mode:
The automatic louvre function can be switched on
or off here for better air distribution. This function is
available via the SC-1 controller only for the hori-
zontal air control blade!
Anti-freeze protection function:
If this function is activated, the unit automatically
switches to heating mode at a room temperature
<7°C. The unit switches off again as soon as a
room temperature of 12°C is reached.
9

Time programs:
Up to 6 time programs can be activated here.
Example: If the indoor unit is to be switched on in
the morning and off in the evening on weekdays,
select number 2 here.
2 time windows appear in the settings menu:
Fig. 9: Time window
In time program one, select Mon. - Fri. with the
desired time and select "ON".
In time window 2, also select Mon. - Fri. but with
the desired time and the "OFF" function.
The indoor unit then switches on and off automati-
cally at these times with the functions previously
selected in the settings menu.
Expert settings:
If the expert level is activated, the functions "IR
remote control lock", "Modes lock" and "Group" are
also available.
Fig. 10: Expert settings
IR remote control:
In this menu item, the IR remote control can be
"locked" or "enabled". If the "locked" function is
activated, the indoor unit can no longer be oper-
ated by IR remote control.
Mode lock:
"Enabled", "Cooling only", "Heating only" and
"Recirculation only" are available. If the function is
set to "enabled", all operating modes can be set
via IR remote control. To avoid 'mode conflicts' in
multi-split systems, the "Cooling only" function can
be selected here, for example. The indoor unit then
only allows the cooling function. It is no longer pos-
sible to select the "Heating" operating mode.
Group:
This allows the indoor unit to be assigned to a unit
group. For example, if you want to combine units
05 and 06 into one group and operate them in par-
allel, select "Add to group 05" in the Group menu
item in the settings for unit 06.
Fig. 11: Unit group
In the unit overview, the units are now grouped
together as group 05 (also recognisable by the
group symbol). You can assign an individual name
for this group in the Smart Web Portal.
"Messages" basic menu
Any malfunctions associated with the respective
indoor units are displayed here. In the event of a
fault, the message symbol lights up red.
Enable expert level:
You can access the expert level via the REMKO
logo in the top right corner of the screen.
You will be asked to enter the expert password,
which is "0321".
The expert level is then active (recognisable by the
word "Expert" after the heading).
REMKO SC-1 Smart-Com