Remotec ZXT-800 User manual

ZXT-800
AC/AV MASTER USER MANUAL
APPs Download: Conexum ZXT-800

CONTENTS
1 Introduction 1
2 Product Overview 1
2.1 Description ................................. 1
2.2 Features .................................. 2
2.3 Z-Wave Glossary .............................. 3
3 Get Started 4
3.1 Step-1 Apply Power to ZXT-800 ....................... 4
3.2 Step-2 Include ZXT-800 to a Z-Wave Gateway ................ 5
3.3 Step-3 Setup Automatic Status Report Associate to Gateway ........ 6
3.4 Step-4 Setup IR code ............................ 6
3.5 Setup IR Code by ZXT-800 App (AC+AV) .................. 9
3.6 IR Code learning .............................. 10
4 Conguration Master Table 15
5 Reset to Factory Default 18
6 Mounting and Placement 19
7 Technical Specications 20
8 Warranty 21
9 Regulatory information 21
10 IC Notice 22
11 Warnings 23
12 Caution 23
Version: 1.0

ZXT-800 AC/AV MASTER USER MANUAL
1. Introduction
ZXT-800 is a Z-Wave plus compliant Z-Wave-to-IR Bridge to control split air conditioner and
entertainment devices by receiving Z-Wave command and translating to Infrared command.
With its comprehensive built-In and cloud-stored IR database (library). ZXT-800 can control
different brands and models of infrared devices worldwide.
ZXT-800 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller
must be used in order to fully utilize the feature.
ZXT-800 is a Z-Wave slave device, it can be up to gateway to setup particular brand with
correct IR code. User can setup the IR (AV + AC) code by “Conexum ZXT-800” App through
Bluetooth download. iOS and Android App are available in Apps store.
2. Product Overview
2.1 Description
Red and Blue LEDs indicator
Micro USB
Battery door
Mounting hole
Temperature sensor
"PROG" Button
External IR Port
Continued on next page
CONTENTS [ 1 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
2.2 Features
• Working as a Z-Wave thermostat (AC) and Simple AV device
• Supports Classic Inclusion, NWI and SmartStart
• Built-in AC IR database for worldwide market, direct use it in gateway
• Cloud-base downloadable AC + AV IR library by Smart phone
• Supports Basic, Smart and Learning search in Smart Phone App
• Support IR learning
• Supports AC ×1 and AV ×3 by download
• Built-in temperature and humidity sensor
• Support rmware upgrades via Over-the-air (OTA) by Z-Wave and BLE
• Z-Wave Plus 2 compliant
• Working on battery (3 ×AAA batteries) or USB power
Continued on next page
CONTENTS [ 2 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
2.3 Z-Wave Glossary
Device or Node Devices and nodes are all terms to describe an individual Z-Wave device.
These are all interchangeable when setting up your Z-Wave network.
Inclusion Add a Z-Wave device to the network.
Exclusion Remove a Z-Wave device from the network.
Remove Remove a Z-Wave device from the network.
Network Wide
Inclusion (NWI)
Network Wide Inclusion (NWI) enables both end-user friendly, Plug and
Play like Z-Wave network installation as well as professional installation
scenario where the inclusion process, in terms of time will be reduced
signicantly. NWI is a feature supported by a new frame type named
Explorer which enables the Z-Wave protocol to implement Adaptive
Source Routing.
Z-Wave Network
A collection of Z-Wave devices is controlled by primary and secondary
controllers operating on the same system. A Z-Wave network has its
own unique ID code so that controllers not in the network cannot control
the system.
Primary Controller
The rst controller is used to set up your devices and network. Only the
Primary Controller can be used to include or remove devices from a
network. It is recommended that you mark the primary controller for
each network for ease in modifying your network.
FLiRS Mode
FLiRS is abbreviation for “Frequently Listening Routing Slave”. FLiRS
mode is targeted for battery operated applications and will enter sleep
mode frequently in order to conserve battery consumption. The
response to Z-Wave command is not as quick as Always Listening
Device. Normally there is 1-2 seconds latency.
Always-Listening
Mode
FLiRS mode is targeted for battery operated applications and will enter
sleep mode frequently in order to conserve battery consumption. The
response to Z-Wave command is not as quick as Always Listening
Device. Normally there is 1-2 seconds latency.
Association
Association is used to organize nodes in different groups allowing the
device to identify the nodes by a group identier. The groups can also be
copied to other devices.
CONTENTS [ 3 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
3. Get Started
User Guide ×1
ZXT-800 ×1
3.1 Step-1 Apply Power to ZXT-800
• 3 ×AAA batteries or Micro USB
• ZXT-800 will detect the rst applied power source to decide what Z-Wave device role
it will be in after included into the Z-Wave gateway:
–Battery = sleeping device (FLiRS mode)
–USB power = always awake device (Always Listening mode)
Please refer to Z-Wave Glossary for more information.
• Once the ZXT-800 is included into a Z-Wave network, the working mode (sleeping or
awake) cannot be changed, unless it is excluded and re-apply the power.
• ZXT-800 can be included and operated in any Z-Wave network with other Z-Wave certi-
ed devices from other manufacturers and/or other applications. All non-battery oper-
ating nodes within the network will act as repeaters regardless of Vendor to increase
reliability of the network.
Caution
• Use new batteries of the recommended type and size only.
• Never mix used and new batteries together.
• To avoid chemical leaks, remove batteries from the ZXT-800 if you do not intend to use
the device for an extended period of time.
• Dispose of used batteries properly; Do not burn or bury them.
CONTENTS [ 4 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.2 Step-2 Include ZXT-800 to a Z-Wave Gateway
There are two methods to include to a Z-Wave network,
Classic inclusion
Step Procedure / Description Status Indicator
1Refer to your primary controller to enter
into the Inclusion Mode or Exclusion Mode -
2
Once the primary controller is ready to
include/exclude the device, press the
“PROG” button once.
Blue LED will ash until complete the step
of inclusion / exclusion. If success, blue
LED will ash twice; if fail, red LED will
ash twice.
SmartStart inclusion
Step Procedure / Description Status Indicator
1
Refer to your primary controller (gateway)
instruction then use Smart Phone App to
scan ZXT-800 SmartStart QR code, it will
include the device into the Z-Wave network
automatically. User can nd out the QR
code at device bottom Z-Wave DSK area.
Make sure your gateway supports
SmartStart feature.
Blue LED will ash until complete the step
of inclusion / exclusion. If success, blue
LED will ash twice; if fail, red LED will
ash twice.
Notes
•It is recommended to perform the Remove (Exclude) procedure before per-forming an
Add (Include) procedure.
•If the Add (Include) process fails, try to Remove (Exclude) from your primary controller
(or reset the ZXT-800 to Factory Default), then repeat the above steps.
Continued on next page
CONTENTS [ 5 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.3 Step-3 Setup Automatic Status Report Associate to Gateway
Please refer to your primary controller (gateway) instruction for more detail. Normally, User
can ignore this step during the setup.
ZXT-800 support 1 association group, Association Group #1 (max. 1 node) is default to
associate with the primary controller (Gateway/Hub/Controller) for ZXT-800 status change
report, refer to below for report details:
• Current Room Temperature (report in precision of 0.5 °C or 1°F), It will be according to
Conguration Parameter 30 setting to decide the trigger level.
• Current Battery Level (Only apply in Low Battery Warning happened)
• Device Reset Locally Notication (Only report when the ZXT-800 has been triggered
the RESET TO DEFAULT)
3.4 Step-4 Setup IR code
The user interface of setup the IR code varies from different gateways. If gateways have
dedicated UI for the IR code setup, please refer to the gateway UI and ignore the below
steps.
If your gateway does not have dedicated UI for ZXT-800 IR code setup, but support Z-Wave
Conguration Command Class. Please refer to below method-A to setup the IR code using
the conguration options in your gateway.
Continued on next page
CONTENTS [ 6 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
There are two methods A) and B) to set up IR code:
A) By Z-Wave gateway conguration (Setup AC code with internal library)
Step Procedure / Description Status Indicator
1Refer to your primary controller user manual, enter
Conguration setting. -
2
Set up IR code with internal library, Input parameter number:
27, Input parameter value: XXXX (AC code no.); User can scan
product QR code (near the Z-Wave logo) which will reach to
our Code Finder Webpage, it obtains a list of AC codes.
Example: AC IR code number: 13; Parameter no.: 27 (Setup IR
code); Parameter value size: 2 bytes; Parameter value: 0013
(AC code number); Then activate or save it in gateway.
Purple LED will turn on.
If success, blue LED
ash ONCE; If fail, red
LED will ash TWICE.
3
Once you nished the IR code setup, please go back to the
control page of ZXT-800 on the gateway’s Browser or App. Try
the function such as (Cool, Temperature Set). If the Air
Conditioner does not respond to the command you set on the
Gateway (Cool, Heat, Auto, Temperature Set, etc⋯.), repeat
step 2 to step 3. Select the next IR code for test from the code
list.
Red LED ashing
ONCE if device sends
out one IR.
Important Notes
• Above procedures are for AC code conguration only.
• Different brand or model of air conditioner has different function. For example, some
air conditioner only support temperature set from 10 °C - 30 °C, if user set 17 °C on
gateway, ZXT-800 will not respond it.
• There are more than 1 code for each brand, some does not support Heat, if User se-
lected a code that does not support Heat but original air conditioner supports Heat
Function, please continue to try next code until the correct one is selected.
• It is not allowed to set up the IR Code when the battery level below 20%.
• You can record down your Device Code for future reference after setting up the ZXT-800
correctly.
• AC code set:
CONTENTS [ 7 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
B) By Smart Phone App “Conexum ZXT-800” (Setup AC + AV with cloud library)
User can download “Conexum ZXT-800” App to implement Basic Search for AC and Smart
Search for AV then setup the IR code. ZXT-800 supports AC ×1 and AV ×3 devices storage
memory. Once your IR code setup completed, user should add ZXT-800 into the Z-Wave
network then control it directly.
Please make sure Z-Wave gateway support AV control interface when you setup AV control.
For more detail operation, please refer to below section.
Continued on next page
CONTENTS [ 8 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.5 Setup IR Code by ZXT-800 App (AC+AV)
1. Please install “Conexum ZXT-800” App, turn on the “Bluetooth” and “GPS”, “WiFi / 4G” on
the Smart phone. The App is available in Google Play & Apple App Store.
2. Pair with ZXT-800 by Smart Phone BLE
• Open the App and follow the Smart phone setup UI.
• Press “Add extender”.
• Trible click on the PROG button within 1.0s to pair with Smart Phone, blue LED will
keep ashing.
• In Smart Phone, please select “Conexum unit” that you want to pair it.
• Once BLE pairing completed, blue LED will turn off.
3. IR code set up
• For AC setup, please type-in or select your brand then follow the Basic Search to
test it one by one.
• For AV setup, please select your device type (TV, CBL, B-Ray, Soundbar⋯), brand
then follow the Smart Search steps to test it.
• Once you have successfully found an IR Code that matches your device, tap to
conrm the code and download it into the ZXT-800.
AC Basic search AV Smart Search
4. After IR code setup completed, please refer to Z-Wave inclusion and add ZXT-800 into
the Z-Wave network, then go to your Z-Wave control panel for device control directly.
CONTENTS [ 9 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
3.6 IR Code learning
In case the IR code can’t support full keys controls, user can use the IR learning function to
capture the IR data from original remote controller, please follow below steps.
AC IR Code Learning
Please refer to “Conguration Master Table” for all conguration settings.
Step Procedure / Description Status Indicator
1Refer to your primary controller user manual, enter
Conguration setting. -
2
To learn AC IR code, look up AC Learning Mapping Table for
learning and decide which IR setting you wants to learn,
example:Parameter number: 25 (Learn AC IR code) Parameter
value size: 1 byte Parameter value: 5 (Cool mode, 20 °C) Then
activate or save it in gateway.
Then Red LED turns
ON for indicating the
IR Code Learning
3
Learning location:
Infrared receiving area
Adjust your original AC remote to
Cool mode 21 °C, aim your original
AC remote to ZXT-800 according to
above position within 1-3cm. Press
and release temperature down
button to adjust to 20 °C, ZXT-800
will learn the IR code automatically.
If the learning is failed or need to learn next IR code, repeat
step 2 to step 3.
Successful: Blue LED
ashes TWICE;
Unsuccessful: Red
LED ashes TWICE
4
Once you nished the IR Code Learning, please go to
Conguration setting page on the Gateway. Parameter
number: 27 (Set IR code) Parameter value size: 2 bytes
Parameter value: 0000 (AC learning location) Then activate or
save it in gateway. ZXT-800 will set the code number to “0000”
which is AC learning code location.
-
Continued on next page
CONTENTS [ 10 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
TIPS
1. User need at least Learn the OFF (Parameter Value 0), and one Temperature Mode
(Parameter Value 2 ∼28) to complete the usage model.
2. Keep away from Incandescent Light or Direct Sunlight during learning.
3. Make sure IR Transmitter of your Original Remote alight with learning diode of ZXT-
800, you may also slight adjust closer or further away the distance of two devices.
Some of Remotes the IR transmitter in hidden behind lens and may not installed
center of remote.
4. Make sure the power is good on both devices, especially the Original remote. Use
Fresh Batteries in both devices recommended. ZXT-800 will not implement the learn-
ing process if the battery level below 20%.
Continued on next page
CONTENTS [ 11 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Parameter-Value
(Storage Location)
Thermostat Command & IR Setting
Storage in Celsius Unit Storage in Fahrenheit Unit
0 OFF OFF
1 ON (RESUME) ON (RESUME)
2 17 °C Cool 63°F Cool
3 18 °C Cool 64°F Cool
4 19 °C Cool 66°F (67°F Cool)
5 20 °C Cool 68°F (69°F Cool)
6 21 °C Cool 70°F (71°F Cool)
7 22 °C Cool 72°F (73°F Cool)
8 23 °C Cool 74°F (75°F Cool)
9 24 °C Cool 76°F Cool
10 25 °C Cool 77°F (78°F Cool)
11 26 °C Cool 79°F (80°F Cool)
12 27 °C Cool 81°F (82°F Cool)
13 28 °C Cool 83°F (84°F Cool)
14 29 °C Cool 85°F Cool
15 30 °C Cool 86°F Cool
16 17 °C Heat 63°F Heat
17 18 °C Heat 64°F Heat
18 19 °C Heat 66°F (67°F Heat)
19 20 °C Heat 68°F (69°F Heat)
20 21 °C Heat 70°F (71°F Heat)
21 22 °C Heat 72°F (73°F Heat)
22 23 °C Heat 74°F (75°F Heat)
23 24 °C Heat 76°F Heat
24 25 °C Heat 77°F (78°F Heat)
25 26 °C Heat 79°F (78°F Heat)
26 27 °C Heat 81°F (82°F Heat)
27 28 °C Heat 83°F (84°F Heat)
28 29 °C Heat 85°F Heat
29 30 °C Heat 86°F Heat
30 Dry Mode Dry Mode
31 Auto Mode Auto Mode
32 Fan Mode Fan Mode
Table 1: AC IR Learning Mapping Table (Parameter number 25)
CONTENTS [ 12 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Mapping Information
1. BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00
2. BASIC Set Value 0xFF will map to Thermostat mode Resume 0x05
3. Energy Saving Mode will map to Thermostat mode OFF
AV IR Code Learning
Please refer to “Conguration Master Table” for all conguration settings.
Step Procedure / Description Status Indicator
1Refer to your primary controller user manual, enter
Conguration setting. -
2
Select AV endpoint (learning location), example: Parameter
number: 38 (Select AV endpoint); Parameter value size: 1 byte;
Parameter value: 2 (AV1); Then activate or save it in gateway.
-
3
To learn AV IR code, look up AV Learning Mapping Table for
learning and decide which IR setting you wants to learn,
example: Parameter number: 26 (Learn AV IR code);
Parameter value size: 1 byte; Parameter value: 11 (VOL+);
Then activate or save it in gateway.
Then Red led turns ON
for indicating the IR
Code Learning.
4
Learning location:
Infrared receiving area
Aim your original
AV remote to ZXT-800 according to
above position within 1-3cm. Press
and hold the “VOL+” button until
blue LED ashes twice. ZXT-800
will learn the IR code automatically.
If the learning is failed or need to
learn next IR code, repeat step 2 to step 4.
Successful: Blue LED
ashes TWICE;
Unsuccessful: Red
LED ashes TWICE
Continued on next page
CONTENTS [ 13 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Parameter-Value (Storage Location) Simple AV Command & IR Setting
Function Z-Wave AV key ID
0 Power 0x0027
1 Input 0x0026
2 Menu 0x001D
3 Smart 0x0185
4 Guide 0x001C
5 Back 0x004B
6 Up 0x001E
7 Down 0x001F
8 OK 0x0024
9 Left 0x0020
10 Right 0x0021
11 VOL+ 0x0003
12 VOL- 0x0002
13 Mute 0x0001
14 Home 0x00AF
15 CH+ 0x0004
16 CH- 0x0005
17 Skip- 0x011C
18 Stop 0x0014
19 Skip+ 0x011B
20 Play 0x0013
21 Pause 0x0015
22 Rewind 0x0017
23 Record 0x0019
24 Fast Forward 0x0016
25 Red 0x009D
26 Green 0x009B
27 Yellow 0x009F
28 Blue 0x009A
Continued on next page
CONTENTS [ 14 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Parameter-Value (Storage Location) Simple AV Command & IR Setting
Function Z-Wave AV key ID
29 0 0x0006
30 1 0x0007
31 2 0x0008
32 3 0x0009
33 4 0x000A
34 5 0x000B
35 6 0x000C
36 7 0x000D
37 8 0x000E
38 9 0x000F
39 Info 0x0011
40 Text 0x013F
Table 2: AV IR Learning Mapping Table (Parameter number 26)
4. Conguration Master Table
Please using the correct data format, if the Gateway support decimal numbering format,
please use decimal value accordingly. If the Gateway support hexadecimal numbering for-
mat, please use hex value accordingly.
Continued on next page
CONTENTS [ 15 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Parameter Name/
Description
Parameter
Number Parameter Value Size (Byte)
Learn AC IR code 25 (0x19)
Storage location 0 –32 for AC IR code
learning (refer to AC learning mapping
table)
1
Learn AV IR code 26 (0x1A)
Storage location 0 –40 for AV IR code
learning (refer to AV learning mapping
table)
1
Set IR code from
built-in AC library 27 (0x1B)
Refer to AC code list nd from code
nder page by code list QR code AC
Learning code number = 0000(0x0000)
2
External IR Emitter
power level 28 (0x1C) 0(0x00) - normal power mode
255(0xFF) - high power mode (default) 1
Set Auto Report
Condition, Trigger
by Room
Temperature
change
30 (0x1E)
0(0x00) = Disable AUTO report
function (default) It can extend
the battery life.
Auto report if room temperature is
different from last report
1(0x01) = 1°F (0.5°C)
2(0x02) = 2°F (1°C)
3(0x03) = 3°F (1.5°C)
4(0x04) = 4°F (2°C)
5(0x05) = 5°F (2.5°C)
6(0x06) = 6°F (3°C)
7(0x07) = 7°F (3.5°C)
8(0x08) = 8°F (4°C)
1
Set Built-in IR
Emitter Control 32 (0x20)
It is allowed to disable internal
IR emitter if use external IR emitter
jack, it can extend the battery life.
0(0x00) = Disable
255(0xFF) = Enable (default)
1
CONTENTS [ 16 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Control Air
conditioner “Swing”
function
33 (0x21) 0(0x00) = Swing OFF
1(0x01) = Swing Auto (default)
1
Temperature and
Humidity Auto
Report
34 (0x22)
Set Auto Report Condition by Time
Interval
0(0x00) = Disable AUTO report
(default)
1(0x01) = 15 mins
2(0x02) = 30 mins
3(0x03) = 1 Hr
4(0x04) = 2 Hrs
5(0x05) = 3 Hrs
6(0x06) = 4 Hrs
1
Calibrate
temperature
reading
37 (0x25)
Temperature offset value
0(0x00) = 0°C (default)
1(0x01) =0.5°C
2(0x02) = 1°C
3(0x03) = 1.5°C
4(0x04) = 2°C
5(0x05) = 2.5°C
6(0x06) =3°C
7(0x07) = 3.5°C
8(0x08) = 4°C
9(0x09) = 4.5°C
10(0x0A) = 5°C
255(0xFF) = -0.5°C
254(0xFE) = -1°C
253(0xFD) = -1.5°C
252(0xFC) = -2°C
251(0xFB) = -2.5°C
250(0xFA) = -3°C
249(0xF9) = -3.5°C
248(0xF8) = -4°C
247(0xF7) = -4.5°C
246(0xF6) = -5°C
1
CONTENTS [ 17 | 23 ]

ZXT-800 AC/AV MASTER USER MANUAL
Select AV endpoint 38 (0x26) 2(0x02) = end point 2 (AV1) default
3(0x03) = end point 3 (AV2)
4(0x04) = end point 4 (AV3)
1
Calibrate humidity
reading 53 (0x35) 0(0x00) = 0% (default)
1(0x01) = 1% to 30(0x1E) = 30%
255(0xFF) = -1% to 226(0xE2) = -30%
1
Trigger BLE
advertising 60 (0x3C)
0(0x00) = Disable BLE advertising
(default)
255(0xFF) = Enable BLE advertising,
please also set Parameter 61 below.
(If the ZXT-800 is installed at ceiling
location, user can trigger BLE
advertisement through the Z-Wave
Conguration without click the
PROG button.)
1
BLE advertising
option 61 (0x3D)
0(0x00) = ZXT-800 advertises for 10
minutes then stop (default)
1(0x01) = ZXT-800 keep advertising,
it is suitable for USB supply power
1
Device reset to
default 160 (0xA0) 255(0xFF): device reset to default 1
5. Reset to Factory Default
• Press and keep holding “PROG” button not less than 10 seconds.
• LED will light up at rst 5 seconds, LED ashes twice then stay off after reset process
completed.
• Device will be excluded from network, All Conguration Parameters will be restored to
factory default. All downloaded IR data and learned data will be cleared.
• ZXT-800 will send Device Reset Locally Notication to gateway.
• ZXT-800 will not implement the Reset to Factory Default when the battery level below
20%.
CONTENTS [ 18 | 23 ]
Table of contents