R0E5562GAPFJ00 User's Manual
R20UT2113EJ0100 Rev.1.00 Page 4 of 8
Sep 05, 2012
5. Connection
To connect this product and user system, follow the
procedure below.
This Product(R0E5562GAPFJ00) can be used for
debugging and on-board evaluation in common by
mounting the NQPACK080SB on the user system.
(1) For debugging
1. Mount the NQPACK080SB on the user system.
Be sure to check that the location of pin 1 is correct.
2. Install the YQPACK080SB after checking for a match
with the position of pin 1 for the NQPACK080SB.
Then use the YQ-GUIDE-S1 to affix the
YQPACK080SB to the NQPACK080SB.
Do NOT use the screws included with the
YQPACK080SB for fixing the YQPACK080SB.
Do NOT use the screwdriver included with the
NQPACK080SB for fixing the YQ-GUIDE-S1.
That is used only for the HQPACK080SB. Note
that you need to provide your own screwdriver.
3. Connect this product after checking for a match with the
position of pin 1 for the YQPACK080SB.
4. Install the connector of the flexible cable from the
emulator to the 38-pin connector on this product.
Hold this product while connecting the cable to avoid
imposing heavy pressure on the 38-pin connector of this
product.
(2) For on-board evaluation
5. Mount an MCU with on-chip flash memory and the
HQPACK080SB (not included) in order on the
NQPACK080SB on the user system.
Before using this product, be sure to read section 7, Notes on Usage.
Warning to Connection:
•Always switch OFF the emulator, this product, and user system before connecting or disconnecting the
emulator. Failure to do so will create a FIRE HAZARD and will damage the emulator, this product, and
user system.
•Make sure that the connectors on both ends of the user-system interface cable are facing the right way
relative to the user-side connector on the emulator and the 38-pin connector on this product,
respectively. Incorrect connection will create a FIRE HAZARD and will damage the emulator, this
product, and user system.
Caution to Mount the NQPACK:
•Check the locations of pin 1 before mounting the NQPACK.
•The tightening torque must be no greater than 0.054 N•m. If the applied torque is not accurately
measurable, stop tightening when the force required to turn the screw (YQ-GUIDE-S1) becomes
significantly greater than that required at the start of tightening. Tightening a screw too much may break
the screw hole of the NQPACK or lead to a faulty connection by cracking solder on the NQPACK side.
•Failure of conduction during operation may be due to a crack in the solder for the NQPACK. Check
conduction with a tester and re-solder the NQPACK as required.
YQPACK080SB
Use a flat-bladed
screwdriver.
indicates pin 1 in this example.
Check that the pin-1 positions on the pad pattern and
all of the components are correctly aligned.
80-pin, 0.65-mm pitch
(PLQP0080JA-A) pad pattern
NQPACK080SB
YQ-GUIDE-S1(× 4)
R0E5562GAPFJ00
(back side:
YQSOCKET080SBF)
1
2
3
Pin 1
(1) For debugging
MCU
HQPACK080SB
(not included)
5
Flexible cable
4
38-pin
connector (2) For on-board evaluation
Figure 3 Connection of the User System and the MCU
Board
WARINIG
CAUTION