Before Getting Started
The user manual provides important operation and maintenance instructions for RENOGY 30A Single Phase Parallel
Kit (hereinaer referred to as Parallel kit).
Read the user manual carefully before operation and save it for future reference. Failure to observe the instructions
or precautions in the user manual can result in electrical shock, serious injuries, or death, or can damage the parallel
kit, potentially rendering it inoperable.
zRenogy ensures the accuracy, suiciency, and the applicability of information in the user manual at the time
of printing due to continual product improvements that may occur.
zRenogy assumes no responsibility or liability for personal and property losses, whether directly and
indirectly, caused by the user’s failure to install and use the product in compliance with the user manual.
zRenogy is not responsible or liable for failures, damages, or injuries resulting from repair attempted by
unqualified personnel, improper installation and operation.
zThe illustrations in the user manual are for demonstration purposes only. Details may appear slightly dierent
depending on product revision and market region.
zRenogy reserves the right to change the information in the user manual without notice. For the latest user
manual, visit renogy.com.
Disclaimer
RENOGY 30A Single Phase Parallel Kit User Manual © 2022 Renogy. All rights reserved.
RENOGY and are registered trademarks of Renogy.
zAll information in the user manual is subject to copyright and other intellectual property rights of Renogy
and its licensors. The user manual may not be modified, reproduced, or copied, in whole or in part, without
the prior written permissions of Renogy and its licensors.
zThe registered trademarks in the user manual are the property of Renogy. The unauthorized use of the
trademarks is strictly prohibited.
Online Manual
User Manual
DC Home App
DC Home App
Download on the

Symbols Used ................................................................................................................................ 1
What’s In the Box? .......................................................................................................................... 1
Get to Know RENOGY 30A Single Phase Parallel Kit............................................................................ 1
Environmental Conditions .............................................................................................................. 2
How to Connect Portable Power Stations in Parallel.......................................................................... 2
Overcurrent Protection .................................................................................................................. 2
Troubleshooting ............................................................................................................................ 3
Specifications................................................................................................................................ 3
General ...............................................................................................................................................................3
Electrical.............................................................................................................................................................3
Important Safety Instructions......................................................................................................... 4
General Safety Information ...............................................................................................................................4
Parallel Kit Safety ...............................................................................................................................................4
Renogy Support............................................................................................................................. 4
Warranty ....................................................................................................................................... 4
Table of Contents

— 1 —
Symbols Used
The following symbols are used throughout the user manual to highlight important information.
WARNING: Indicates a potentially dangerous condition which could result in injury or death.
CAUTION: Indicates a critical procedure for safe and proper installation and operation.
NOTE: Indicates an important step or tip for optimal performance.
What’s In the Box?
VERSION A1
Single Phase Parallel Kit 30A
RENOGY
RSA30SGPK
USER MANUAL
RENOGY 30A Single Phase Parallel Kit × 1 User Manual × 1
Make sure that all accessories are complete and free of any signs of damage.
Get to Know RENOGY 30A Single Phase Parallel Kit
United States/Canada/Japan Europe/United Kingdom/
Australia/South Korea/China
Parallel Connector
Power Indicator Overload Protector
AC Outlets
Parallel Connector
Grounding Terminal

— 2 —
Environmental Conditions
KEEP DRY FRAGILE VENTILATION
Ambient Temperature: -4°F~104°F / -20°C~40°C
How to Connect Portable Power Stations in Parallel
Single-Phase AC Device
Grounding
Banana Plug
(4mm)
1
2 2
3
This Side Up
Please inspect the parallel kit before each use. Stop using the parallel kit if any visible damages including
cracks, dents, and deformation or abnormalities including unusual smells and heating are observed.
The total output power of the parallel kit is determined by the AC output rating of the portable power
stations connected to it. Please read the user manual of portable power stations before the parallel
connection. Do not overload portable power stations.
Please ensure that both portable power stations are of the same models.
Please ensure that the AC outlets of both portable power stations have the same output voltage and
output frequency.
Overcurrent Protection
The parallel kit is integrated with the Overload Protector. When the parallel kit is overloaded, the Overload Protector
will pop up automatically and stop the output current to protect the connected loads. In such case, disconnect all
the loads, and then press down the Overload Protector to reset it. Contact us for help if the Overload Protector pops
up again: renogy.com/contact-us.
NEMA 5-20R: 20A
TT-30R: 30A
Universal Outlet: 16A
Please check the current ratings of the devices before the connection. Do not exceed the current ratings
of the AC outlets.

— 3 —
Troubleshooting
If the parallel kit does not operate properly, refer to the table below for possible causes and corrective steps. If the
corrective steps do not work, contact our customer service through renogy.com/contact-us/.
Phenomenon Possible Causes Corrective Steps
Power
Indicator Not
Lighting Up
Single Phase Parallel
Failure
zCheck if both portable power stations are turned on.
zCheck if the AC outlets of both portable power stations are turned
on.
zCheck if the parallel connections are solid.
zDisconnect the parallel kit from both portable power stations.
zCheck the models of both portable power stations. Stop
connecting both portable power stations in parallel if they are of
dierent models.
zCheck the output voltage of the AC outlets of both portable power
stations. Stop connecting both portable power stations in parallel
if their AC outlets have dierent output voltages.
zSet the AC outlets of both portable power stations to the same
output frequency.
zFully charge the portable power stations.
zReconnect the portable power stations in parallel with the parallel
kit.
Ground Fault
Error On
Device
Floating Ground
zDisconnect the devices from the AC outlets.
zPlug a neutral ground bonding plug into one of the AC Outlets.
zConnect the devices to the unused AC outlets. Power can be
resumed.
Specifications
General
Dimensions
9.29 x 4.61 x 2.24 inch / 236 x 117 x 57 mm (US / CA / JP)
8.35 x 4.61 x 2.24 inch / 212 x 117 x 57 mm (EU / UK / AU / KR / CN)
(Parallel Cables and Parallel Connectors Excluded)
Weight 1.96 lbs. / 0.89 kg (US / CA / JP)
2.09 lbs. / 0.95 kg (EU / UK / AU / KR / CN)
Operating Temperature -4°F~104°F / -20°C~40°C
Parallel Cable Length 3.28 / 1.0 m
Electrical
Input/Output Voltage 100V (JP) / 120V (US & CA) / 220V~240V (EU, UK, AU, KR & CN)
Maximum Input/Output Power 6000W (JP) / 7200W (US & CA) / 11040W (EU, UK, AU, KR & CN)
AC Outlet Current Rating 20A (NEMA 5-20R) / 30A (TT-30R) / 16A (Universal Outlet)

— 4 —
Important Safety Instructions
General Safety Information
zKeep the parallel kit out of the reach of young children.
zDo not dispose of the parallel kit as household waste. Comply with local, state, and federal laws and regulations
and use recycling channels as required.
zIn the event of fire, use fire extinguishers suitable for electrical equipment. Acceptable fire extinguishers include
an FM-200 or CO fire extinguisher.
zDo not expose the parallel kit to flammable or harsh chemicals or vapors.
zDo not expose the parallel kit to strong electrostatic fields, strong magnetic fields, or radiation.
Parallel Kit Safety
zDo not puncture, drop, crush, penetrate, shake, strike, or step on the parallel kit.
zDo not open, dismantle, repair, tamper with, or modify the parallel kit.
zDo not insert foreign objects into the parallel kit.
zPlease remove all connections before cleaning the parallel kit.
Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at:
renogy.com/support/downloads contentservice@renogy.com
For technical questions about your product in the U.S., contact the Renogy technical support team through:
renogy.com/contact-us 1(909)2877111
For technical support outside the U.S., visit the local website below:
Canada ca.renogy.com China www.renogy.cn
United
Kingdom uk.renogy.com U.S. www.renogy.com
Australia au.renogy.com Japan renogy.jp
France fr.renogy.com Germany de.renogy.com
Spain es.renogy.com South Korea kr.renogy.com
Italy it.renogy.com Other Europe eu.renogy.com
Warranty
Check out the warranty policies for the product from your local Renogy website. For customers in the U.S., register
your product and get your e-warranty at https://renogy.force.com/helpcenter/s/warrantyregister.

RENOGY.COM
Renogy aims to empower people around the world through education and distribution of DIY-friendly
renewable energy solutions.
Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your
experiences with your solar energy journey, and connect with like-minded people who are changing the
world in the Renogy Power Plus community.
We intend to be a driving force for sustainable living and energy independence.
In support of this eort, our range of solar products makes it possible for you to minimize your carbon
footprint by reducing the need for grid power.
Renogy Empowered
Live Sustainably with Renogy
Did you know? In a given month, a 1KW solar energy system will...
Save 170 pounds of coal from being burned
Save 300 pounds of CO2 from being released into the atmosphere
Save 105 gallons of water from being consumed
@Renogy Solar @Renogy@renogyoicial
Renogy Power PLUS
Renogy reserves the right to change the contents of this manual without notice.
This manual suits for next models
1
Table of contents
Other Renogy Portable Generator manuals

Renogy
Renogy LYCAN 5000 User manual

Renogy
Renogy PHOENIX 200 User manual

Renogy
Renogy LYCAN 5000 Power Box User manual

Renogy
Renogy PHOENIX 500 User manual

Renogy
Renogy LYCAN 5000 User manual

Renogy
Renogy PHOENIX ELITE R300PHXE User manual

Renogy
Renogy PHOENIX 300 User manual

Renogy
Renogy PHOENIX 1000 User manual
Popular Portable Generator manuals by other brands

Siemens
Siemens SINAMICS S120 Instruction for installation in cabinets for marine drive applications

Festo
Festo VABF-S4-CB-VH Series Instructions & Operating

Pacific Scientific
Pacific Scientific Redi-Line DA12A Installation and service manual

Wen
Wen DF250i user manual

Picotest
Picotest G5100A manual

YOKOGAWA
YOKOGAWA PG400 user manual