RE305_DSC_Temp_Instructions Page 1 of 3 16-Ma -14
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Wireless
Security
Solutions
RE305 Temp Range, 3-Function, DSC-Compatible
Features
• Freeze, Overheat warnings, plus Magnetic Reed sensor (magnet not
included)
o Can be used as an or all of the functions.
o Unique Electronic Serial Numbers (ESNs) for each function.
• Cover tamper for each ESN Zone.
• Strong, reliable RF signal.
• 8-10 ear batter life on CR123A batter .
• Low Batter indication.
• 3.3x1.4x1.1 inches.
Key Instructions
• Batter “+” faces towards spring.
• Activating Zones
In order to extend batter life and prevent RF pollution, the unit
comes from the factor with onl the Freeze Zone operating. The
enrolling actions (listed next) activate the Overheat and Reed
Zones.
ACTIVATE ONLY THE ZONES YOU NEED:
• Enrolling: Place control panel in enroll mode… then for…
Freeze - Zone 0: ESN ends in “0”:
Enroll b :
• …installing batter .
Sensor sends Freeze alarm & enrolls.
Overheat – Zone 1: ESN ends in “1”:
Enroll b :
• Holding Tamper down,
• Leaving a magnet awa from Reed Switch,
• …while installing batter .
Sensor sends Overheat-Alarm & enrolls.
Reed – Zone 2: ESN ends in “2”:
Enroll b :
• Holding Tamper down,
• Having a magnet next to Reed Switch,
• …while installing batter .
Sensor sends magnet alarm & enrolls.
RE305_DSC_Temp_Instructions Page 2 of 3 16-Ma -14
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
peration
• Freeze (Freeze ESN)
Alarm: when room temperature drops below 45F.
Tamper: when cover is opened
Supervisor : ever hour
• Overheat (Overheat ESN)
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened
Supervisor : ever hour
• Magnetic Reed (Mag ESN)
Alarm: when magnet is awa from sensor.
Tamper: when cover is opened
Supervisor : ever hour
Specifications
DSC Device T pe: 2 (Door/Window)
Freeze Alarm Temp: 45F +/- 2F
Freeze Restore: when temp increases 4F from alarm
Overheat Alarm Temp: 100F +/- 2F
Overheat Restore: when temp decreases 4F from alarm
Magnet Trip Distance: 1 inch nominal
Mounting hardware: # 4 or #6 screws
Replacement Batter : CR123A 1550 mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal Picture
Temp Element
Switch Element