RE619_Cryptix_Flood_Temp_Instructions Page 1 of 3 7-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
RE619 Flood/Temp Range, CryptiX™-Compatible
Home Disaster™ ensor
Features
•
Tri-Mode Environmental Sensing:
o
Flood/Moisture Sensor
o
Freeze – for Furnace Failure
o
verheat – for Furnace runaway or Air Conditioning failure.
•
Cover tamper.
•
Strong, reliable RF signal.
•
8-10 year battery life on CR123A battery.
•
Low Battery indication.
•
3.3x1.4x1.1 inches.
Key Instructions
• Battery “+” faces towards spring.
• Flood
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
• Freeze
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
• verheat
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
Enrollment
• Place panel in enrollment mode.
• Tamper the device.
• By default the Flood will enroll first – to add just the Freeze or just the
overheat, or use all three, go to resolutionproducts.com/helixsetup
RE619_Cryptix_Flood_Temp_Instructions Page of 3 7-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Specifications
Flood sensing: Titanium contacts
100K- hm nominal (D N T use an E L resistor)
Transmitter handles 1 or 2 flood elements, no more.
0.04 inch floor spacing to eliminate floor
condensation falses.
Checks for moisture every 5 seconds: needs two
positive moisture checks to send Flood alarm.
(test mode: every second when cover is off)
Freeze Alarm: 45F +/- 2F
Restores when temp increases 4F from alarm
verheat Alarm Temp: 100F +/- 2F
Restores when temp decreases 4F from alarm
Mounting hardware: #6 or #8 screws
Dual Mode mounting:
Screwed to floor
Screwed to wall
Terminal wire capacity: 16 Gauge
Replacement Battery: CR123A 1550 mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal & Close-up Pictures
Temp Element
floor mounting