manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Resolution Products
  6. •
  7. Accessories
  8. •
  9. Resolution Products RE619 User manual

Resolution Products RE619 User manual

Other Resolution Products Accessories manuals

Resolution Products RE305 User manual

Resolution Products

Resolution Products RE305 User manual

Resolution Products Alula RE306 User manual

Resolution Products

Resolution Products Alula RE306 User manual

Resolution Products RE205 User manual

Resolution Products

Resolution Products RE205 User manual

Resolution Products RE222 User manual

Resolution Products

Resolution Products RE222 User manual

Resolution Products RE206 Operating and maintenance instructions

Resolution Products

Resolution Products RE206 Operating and maintenance instructions

Resolution Products RE311 Mighty Mouse User manual

Resolution Products

Resolution Products RE311 Mighty Mouse User manual

Resolution Products RE153 User manual

Resolution Products

Resolution Products RE153 User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

RE619_Cryptix_Flood_Temp_Instructions Page 1 of 3 7-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
RE619 Flood/Temp Range, CryptiX™-Compatible
Home Disaster™ ensor
Features
•
Tri-Mode Environmental Sensing:
o
Flood/Moisture Sensor
o
Freeze – for Furnace Failure
o
verheat – for Furnace runaway or Air Conditioning failure.
•
Cover tamper.
•
Strong, reliable RF signal.
•
8-10 year battery life on CR123A battery.
•
Low Battery indication.
•
3.3x1.4x1.1 inches.
Key Instructions
• Battery “+” faces towards spring.
• Flood
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
• Freeze
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
• verheat
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
Enrollment
• Place panel in enrollment mode.
• Tamper the device.
• By default the Flood will enroll first – to add just the Freeze or just the
overheat, or use all three, go to resolutionproducts.com/helixsetup
RE619_Cryptix_Flood_Temp_Instructions Page of 3 7-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Specifications
Flood sensing: Titanium contacts
100K- hm nominal (D N T use an E L resistor)
Transmitter handles 1 or 2 flood elements, no more.
0.04 inch floor spacing to eliminate floor
condensation falses.
Checks for moisture every 5 seconds: needs two
positive moisture checks to send Flood alarm.
(test mode: every second when cover is off)
Freeze Alarm: 45F +/- 2F
Restores when temp increases 4F from alarm
verheat Alarm Temp: 100F +/- 2F
Restores when temp decreases 4F from alarm
Mounting hardware: #6 or #8 screws
Dual Mode mounting:
 Screwed to floor
 Screwed to wall
Terminal wire capacity: 16 Gauge
Replacement Battery: CR123A 1550 mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal & Close-up Pictures
Temp Element
Strain relief for
floor mounting
RE619_Cryptix_Flood_Temp_Instructions Page 3 of 3 7-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Notices
Warranty
Resolution Products, Inc. will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could void
the user's authority to operate this equipment.
FCC ID: U5X-RE301
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
( )This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
( )l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE301