RE926X-03-00_Flexible Bus WiFi CommunicatorPage 5 of 10 2-No -15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
Reporting Codes for DSC panels:
The following table shows all events reported when connected to a DSC Panel.
Panel Low Battery/Low Battery Restore
Periodic Test Transmission
Periodic Test with Trouble Transmission
Automatic Contact ID is not supported. Manually programmed reporting codes
are only supported for alarms on zones -64 ([320] – [324]) and for alarms on
the PGM2/Aux input ([329]:[4]). The PGM2/Aux input is reported as zone
number 99.
If Report Codes have not been manually programmed for zone alarms, zone
alarm reporting codes default to:
• Any zone alarm (zones -64): Code 30 (Burglary)
• PGM2/Aux input (zone 99, likely a 2-wire Smoke): Code 0 (Fire)
Be sure to verify that all codes are being properly reported to the central
station after you have installed the communicator module or modified any
reporting program settings in the DSC installer programming menu.
Caddx NX Programming:
Compatible with all NX series panels
) Refer to server setup instructions and setup account on the Dealer Portal.
2) Be sure to add a contact that uses the system MASTER CODE to the
account before connecting the module. This will ensure the module can
properly communicate with and configure required system settings.
3) Disarm the system (all partitions).
4) Power down the NX system.
5) Set the RE926X panel selector switch to CDX: DSC CDX HW UTC
6) Connect the NX panel and the RE926X as shown in the Wiring Instructions
above.
7) Apply power to the NX system. During this process, the communicator will
program the following settings:
Enable Opening and Closing reports
Set Telephone Line Cut delay to 0 (no TLM)
8) Installation complete.
Important: Do not attempt to enter program mode until the CS and Platform LEDs
have stopped flashing
.
Additional Notes for NX installations:
1. Some NX panels limit the number of non-keypad devices they support. Be sure
that the panel you are connecting the communicator to does not have more than
the number of support devices connected.
2. User codes that are added to the system or edited thru the communicator will
have the default or previous partitions enabled. If you desire the users to have
different partitions enabled, you will need to modify the partitions thru the NX
keypad.
3. 6-digit access codes are not supported.
RE926X-03-00_Flexible Bus WiFi CommunicatorPage 6 of 10 2-No -15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
Concord Programming
Compatible with Concord 4.
1) Refer to server setup instructions and set up the account on the Dealer Portal.
2) Be sure to add a contact that uses the system MASTER CODE to the account before
connecting the module. This will ensure the module can properly communicate with and
configure required system settings.
3) Using the System’s Installers Code
a. Turn off ACCESS CODE LOCK (0003).
b. Delete phone numbers for CS1-CS3 (01000 – 01020).
c. Turn on OPENING REPORTS for partition 1 (06100).
d. Turn on CLOSING REPORTS for partition 1 (06101).
4) If there is an automation or wireless reporting device (i.e. automation module, cell
backup module) already connected to the panel, remove the device and delete from the
panel. Concord 4 only supports 1 automation bus device.
5) Disarm the System (all partitions).
6) Power down the Concord System.
7) Set the RE926X selector switch to UTC DSC CDX HW UTC
8) Connect the Concord panel and the RE926X as shown in the Wiring Instructions above.
9) Apply power to the Concord System.
10) If this is the first time the module is powered with the panel
a. Do not press any keys on the keypad for the first 2 minutes after power up.
b. After 2 minutes, initiate a bus scan (8+installer code+01)
c. Do not press any keys on the keypad for 1 minute after you have
performed the bus scan.
11) If the CS or Platform LED is still blinking refer to “Trouble Shooting the Panel
Connection”.
12) It is normal for the keypad to display “Enter Light Key” a few times after connecting
the module to the panel. If the keypad continues to display “Enter Light Key”, verify you
have the correct system master code setup in the account.
13) Installation is complete.
IMPORTANT: Be sure to turn Off ACCESS CODE LOCK before adding the module!
Trouble Shooting the Panel Connection:
If the “CS” or “Platform” LEDs are blinking, here are possible
problems:
Incorrect wiring
Incorrect panel switch position
Unsupported panel version
Unsupported panel model
Panel is in Installer Program mode
Vista Specific:
AUI not enabled
AUI used for some other function
LRR not enabled
Another LRR or IP/GSM device connected to panel bus
Factory Default Button and WPS button
a) Holding the Factory Default button for 5 seconds will reset the RE926X Communicator
b) Holding the Factory Default button for 0 seconds (LEDs will flash off
twice) will set the RE926X to factory defaults
c) Press and Release the WPS button (WiFi Led flashes slowly) for
connecting Primary Router
d) Press and Hold the WPS until WiFi LED flashes rapidly for connecting to Backup Router
e) Press and Hold the Factory Default button, then pressing the WPS button
for approximately one second (Wifi LED will flash) to put the
communicator into Access Point mode