RE927X-03-00_Flexible Bus 3G GSM Communicator Page 3 of 0 7-Aug- 5
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
Vista 20P and Vista 15P Programming:
Compatible Honeywell Panels:
Vista 20P (version 3.0 or later) (controls partition 1 only)
Vista 15P (version 3.0 or later)
1) Re er to server setup instructions and set up the account on the Dealer Portal.
2) Be sure to add a contact that uses the system MASTER CODE to the account be ore
connecting the module. This will ensure the module can properly communicate
with and con igure required system settings.
3) Disarm the system (all partitions).
4) The RE927X automatically communicates with the Vista using AUI device 2.
The panel is probably de aulted to this. I not, enable AUI 2 in the *189 ield. I a
device is already using AUI 2, that device must be moved to another AUI address (AUI
1, or Vista 15P, AUI 1, 3 or 4 or Vista 20P
5) The 2
nd
entry in the *91 ield must be set to 0 or 1 based on the current call
waiting disable setting (0 = call waiting disable not used, 1 = call waiting disable is
used). Either o these settings disable the RIS eature and allows the RE927X to
communicate with the Vista panel. Vista panels o V10.24 or later no longer have a
RIS option, no action is required with these panels.
a) Vista 15p and 20p panel versions 10.21 and later have the keypad lockout eature enabled
by de ault. It is recommended that this eature be disabled to prevent possible keypad
lockout conditions i the system master code in the IGM is not synchronized with the master
code in the Vista panel. Use programming option *188 to disable keypad lockout.
b) I it is required to have the keypad lockout eature enabled, it is critical that the system
master code be set up as a contact or this account be ore connecting the module to the panel
(see Step 2 above). Also all changes to the system master code must be done at the user portal
or dealer portal, not at the keypad. Failing to do this may result in a keypad lockout condition.
6) Power down the Vista system.
7) Set RE927X panel selector switch to Honeywell: DSC CDX HW UTC
8) Connect the Vista and RE927X as shown in the Wiring Instructions above.
9) Apply power to the Vista 15P/20P system. It will automatically program.
a) Be sure ALL partitions are disarmed.
b) First, the Vista control panel will be busy or 50-60 seconds a ter powerup.
c) Then, the module will enable the ollowing settings automatically:
IP/GSM device (*29) = 1 (enabled)
Communicate to IP/GSM device irst (*55) = 1 (IP/GSM irst)
Opening Report (*65) = 1 (enabled)
Closing reports (*66) = 1, 1 (stay closing & away closing reports enabled)
Alarm cancel report (*68) = 1 (enabled)
AC Power restoral report (*73) = 1 (enabled)
Low Battery restoral report (*74) = 1 (enabled)
Phone Monitor (*92) = 0 (disabled)
10) Finally, the keypad(s) should display "DISARMED Ready to Arm".
11) Installation is complete.
RE927X-03-00_Flexible Bus 3G GSM Communicator Page 4 of 0 7-Aug- 5
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
DSC Power Series Programming:
Compatible DSC Panels:
PC580 (Power 432) PC5020 (Power 864)
PC1555 (Power 632) PC1616
PC1555MX (Power 632) PC1832
PC5010 (Power 832) PC1864
PC5015 (Power 832)
1)
Re er to server setup instructions and set up the account on the Dealer Portal.
2)
Be sure to add a contact that uses the system MASTER CODE to the account be ore
connecting the module. This will ensure the module can properly communicate
with and con igure required system settings.
3)
Using the system’s Installer Code:
a) Disable the Communicator ([380]:[1])
b) Disable the Telephone Line Monitor ([015]:[7])
c) Delete Telephone Numbers (programming section 301-303)
d) Veri y Alt Comm ([351]:[5]) is enabled
e) Veri y T-Link is Disabled ([382]:[5])
) Veri y Master Code Not Changeable is Disabled ([015]:[6])
g) Veri y Access Code Required or *1, *2, *3 menus is disabled ([022]:[1])
h) Veri y that keypad lockout is either zero(disabled) or higher than 6 ([012])
i) I you have removed any bus devices, per orm a Module Supervision Reset ([902])
4)
Veri y Alarm report codes are setup properly or zones that are being used, 1-64
(programming section 320-349). System will report as Burg(130) i programmed as
FF.
5)
I using Aux input (PGM2) veri y Aux input report codes are setup properly
(programming section 329:4). System will report as Fire (110) i programmed as FF.
6)
To enable reporting o the Period Test Transmission, program the “periodic Test
Transmission” ([348]:[4]) and the “Periodic Test Transmission with Trouble”
([348]:[3]) reporting codes to “02”
7)
All other reports are hardcoded in the gateway and cannot be changed regardless
o what is entered in the programmed location.
8)
Format and account number have no e ect on reporting.
9)
Disarm the system (all partitions)
10)
Power down the DSC system.
11)
Set RE927X panel selector switch to DSC: DSC CDX HW UTC
12)
Connect the DSC Panel and RE927X as shown in the Wiring Instructions above.
13)
Apply power to the DSC system.
14)
The DSC control panel will begin automatic con iguration. This can take up to 2
minutes.
15)
Installation complete.