Retekess T-AC03 User manual

Metal Standalone Keypad Access Control
User Manual
T-AC03
EU

CONTENTS
Description
Features
Specifications
Packing List
Installation
Wiring
To Reset to Factory Default
Anti Tamper Alarm
Sound and Light indication
Detailed Programming Guide
The unit operating as a Wiegand Output
Reader
INHALT
Beschreibung
Eigenschaften
Spezifikationen
Packliste
Installation
Verkabelung
Zurücksetzen auf Werkseinstellungen
Diebstahlschutz Alarm
Ton- und Leichte Anweisungen
Detaillierte Programmieranleitung
Das Gerät arbeitet als Wiegand Output
Reader
Catalogue
Description
Caractéristiques
Spécification
Contenu de l’emballage
Installation
Câblage
Pour reinitialiser les réglages par défaut
Alarme d’antivol
Indicateur de bip sonore et les témoins
lumineux
Guide de programmation détaillé
L'unité fonctionnant comme un lecteur
de sortie Wiegand
.................................................01
.....................................................01
.............................................01
...............................................02
..................................................02
.........................................................02
......................04
.....................................04
........................04
....................04
........................................................07
.............................................08
............................................08
...........................................08
.....................................................09
..................................................09
...............................................09
........11
................................11
..................11
.............11
........................................................15
.................................................16
.........................................16
...............................................16
.............................17
..................................................17
......................................................17
....19
..........................................19
.....................................................19
...............19
......................................23
CONTENUTO
Descrizione
Caratteristiche
Specificazione
Lista imballaggio
Installazione
Schema cablaggio
Ripristinare i valori predefiniti di fabbrica
Allarme Anti-manomissione
Indicazione suono e LED
Guida alla programmazione dettagliata
L'unità funziona come un lettore di uscita
Wiegand
CONTENIDO
Descripción
Funciones
Especificaciones
Lista de embalaje
Instalación
Cable
Restaura la configuración de fábrica
Alarma antimanipulación
Indicación de sonido y luz
Guía detallada de programación
Funciona como lector de salida
Wiegand
WARNING
.................................................24
............................................24
............................................24
........................................25
...............................................25
.....................................25
...27
.......................27
............................27
.....27
.....................................................30
................................................31
...................................................31
........................................31
.......................................32
..................................................32
..........................................................32
.........34
...........................34
..........................34
................34
.....................................................38

Operating Voltage DC 12Vf10%
User Capacity 2000
Card Reading Distance 3-6 cm
Active Current ˘60mA
Idle Current 25±5 mA
Lock Output Load Max 3A
Alarm Output Load Max 20A
Operating Temperature -45ć60ć
Operating Humidity 10%- 90% RH
Waterproof Conforms to IP68
Adjustable Door Relay time 0 -99 seconds
Adjustable Alarm Time 0- 3 minutes
Wiegand Interface Wiegand 26 bit
Wiring Connections Electric Lock, Exit Button, External Alarm,External reader
1
Description
The unit is single door multifunction standalone access controller or a Wiegand output keypad or
card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed
in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a
bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and
conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN
option. The inbuilt card reader supports 125KHZ EM cards,13.56MHz Mifare cards. The unit has
many extra features including lock output current short circuit protection, Wiegand output , and a
backlit keypad. These features make the unit an ideal choice for door access not only for small
shops and domestic households but also for commercial and industrial applications such as
factories, warehouses, laboratories, banks and prisons.
Features
:DWHUSURRIFRQIRUPVWR,3
6WURQJ=LQF$OOR\(OHFWURSODWHGDQWLYDQGDOFDVH
)XOOSURJUDPPLQJIURPWKHNH\SDG
XVHVVXSSRUWV&DUG3,1&DUG3,1
&DQEHXVHGDVDVWDQGDORQHNH\SDG
%DFNOLJKWNH\V
:LHJDQGLQSXWIRUFRQQHFWLRQWRH[WHUQDOUHDGHU
:LHJDQGRXWSXWIRUFRQQHFWLRQWRDFRQWUROOHU
$GMXVWDEOH'RRU2XWSXWWLPH$ODUPWLPH'RRU2SHQWLPH
9HU\ORZSRZHUFRQVXPSWLRQP$
)DVWRSHUDWLQJVSHHGPVZLWKXVHUV
/RFNRXWSXWFXUUHQWVKRUWFLUFXLWSURWHFWLRQ
(DV\WRLQVWDOODQGSURJUDP
%XLOWLQOLJKWGHSHQGHQWUHVLVWRU/'5IRUDQWLWDPSHU
%XLOWLQEX]]HU
5HG<HOORZDQG*UHHQ/('6GLVSOD\WKHZRUNLQJVWDWXV
Specifications

Please ensure that all the above contents are correct. If any are missing please notify the supplier
of the unit.
Installation
5HPRYHWKHEDFNFRYHUIURPWKHNH\SDGXVLQJWKHVXSSOLHGVSHFLDOVFUHZGULYHU
'ULOOKROHVRQWKHZDOOIRUWKH6HOIWDSSLQJVFUHZVDQG,KROHIRUWKHFDEOH
3XWWKHVXSSOLHGUXEEHUEXQJVWRLQWRWKHWZRKROHV
)L[WKHEDFNFRYHUILUPO\RQWKHZDOOZLWK6HOIWDSSLQJVFUHZV
7KUHDGWKHFDEOHWKURXJKWKHFDEOHKROH
$WWDFKWKHNH\SDGWRWKHEDFNFRYHU
Wiring
2
Colour Function Description
Pink BELL_A Doorbell button one end
Pale blue BELL_B Doorbell button to the other end
Green D0 WG output D0
White D1 WG output D1
Grey ALARM Alarm negativealarm positive connected 12 V+
<ellow OPEN Exit button one endthe other end connected GND
Brown D_IN Magnetic switch one endthe other end connected GND
Red 12V+ 12V + DC Regulated Power Input
Black GND 12V - DC Regulated Power Input
Blue NO Relay normally-on endConnect positive electric lock
Purple COM Relay Public end, connect GND
Orange NC Relay Closed endconnect negative electric lock "-"
Packing List
Name Quantity Remarks
Keypad 1
User manual 1
Screw driver 1 ĭ20mm×60mm,Special for keypad
Rubber plug 2 ĭ6mm×30 mm,usedforfixing
Self tapping screws 2 ĭ4mm×28 mm,usedforfixing
Star screws 1ĭ3mm×6mm, used for fixing

3
special power supply diagram:
common power supply diagram:

To Reset to Factory Default
a. Disconnect power from the unit
b. Press and hold # key whilst powering the unit back up
c. On hearing two “Di” release # key, system is now back factory settings
NOTE: note only installer data is restored, user data will not be affected
Anti Tamper Alarm
7KHXQLWXVHVD/'5OLJKWGHSHQGHQWUHVLVWRUDVDQDQWLWDPSHUDODUP,IWKHNH\SDGLVUHPRYHG
from the cover then the tamper alarm will operate.
Sound and Light indication
Detailed Programming Guide
1. User Settings
4
Operation Status Red Light Green Light Yellow Light Buzzer
Power on - Bright - Di
Stand by Bright - - -
Press keypad - - - Di
Operation successful - Bright - Di
Operation failed - - - DiDiDi
Enter into programming mode Bright - -
In the programming mode - - Bright Di
Exit from the programming mode Bright - - Di
Open the door - Bright - Di
Alarm Bright - - Alarm
To enter the programming mode *Master code #
999999 is the default factory master code
To exit from the programming mode *
Note that to undertake the following programming the master user must be logged in
To change the master code 0New code New code# #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
Entry is by card only
Entry is by card and PIN together
(QWU\LVE\HLWKHUFDUGRU3,1GHIDXOW
3 0 #
3 1 #
3 2 #

5
To delete a PIN user 2User ID number #
To change the PIN of a PIN user
(This step must be done out of
programming mode)
*
ID
number # Old PIN # New PIN #
New PIN #
To add a cardXVHU0HWKRG
This is the fastest way to enter cards,
user ID number auto generation.
To add a cardXVHU0HWKRG
This is the alternative way to enter cards
using User ID Allocation. In this method a
User ID is allocated to a card. Only one
user ID can be allocated to a single card.
To add a cardXVHU0HWKRG
Card number is the last 8 digits printed
on the back of the card,user ID number
auto generation
To add a cardXVHU0HWKRG
In this method a User ID is allocated to a
card number. Only one user ID can be
allocated to the card number
To delete a card user by card. Note users
can be deleted continuously without
exiting programming mode
To delete a card user by user ID. This
option can be used when a user has lost
their card
To delete a card user by card number.
This option can be used when the user
want to make the change but the card
has lost
Cards can be added continuous exiting programming
mode
1Read card #
User can be added continuously without exiting
programming mode
1ID number #Read card #
User can be added continuously without exiting
programming mode
Note users can be deleted continuously without
exiting programming mode
User can be added continuously without exiting
programming mode
1Card number #
1ID number. #Card number. #
2Read Card #
To add a user in either card or PIN mode, i.e. in the mode. (Default setting)3 2 #
To add a Pin user 1User ID number PIN# #
1User ID no 1 PIN# # User ID no 2 #
PIN #
The ID number is any number between 1 & 2000.
The PIN is any four digits between 0000 & 9999
with the exception of 1234 which is reserved. Users
can be added continuously without exiting
programming mode as follows:
Users can be deleted continuously without exiting
programming mode
2User ID #
2Card number #

To Add a card and PIN user
7KH3,1LVDQ\IRXUGLJLWVEHWZHHQ
& 9999 with the exception of 1234 which
LVUHVHUYHG
To change a PIN in card and PIN mode
0HWKRG1RWHWKDWWKLVLVGRQHRXWVLGH
programming mode so the user can
undertake this themselves
To change a PIN in card and PIN mode
0HWKRG1RWHWKDWWKLVLVGRQHRXWVLGH
programming mode so the user can
undertake this themselves
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the
inside buzzer will beep automatically to remind people to close the door and continue for 1
minute before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the
inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between
0-3 minutes with the default being 1 minute.
To delete a Card and PIN user just delete
the card
To set door relay strike time Master code # 4 099 # *
*
0-99 is to set the door relay time 0-99 seconds
Door Open Detection
6
To add a card and PINXVHULQFDUGDQG3,1PRGH
Add the card as for a card user
Press to exit from the programming mode
Then allocate the card a PIN as follows:
The operating is the same as adding and deleting a
card user in
*
*Read card 1234 #PIN #PIN #
*Read Card Old PIN #New PIN #
New PIN #
*ID number # New PIN #Old PIN #
New PIN #
2User ID #
To Add and Delete a card user
20000 #
To unlock the door
For a PIN user Enter the PIN then press #
For a card User Read card
For a card and PIN user Read card then enter PIN #
1 #3
To add a cardXVHULQFDUGPRGH
0 #3
2 #3
To delete ALL users. Note that this is a
dangerous option so use with care
To delete All users
Relay Output Delay Time
2. Door Settings

The unit operating as a Wigeand Output Reader
In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be
connected to any controller which supports a Wiegand 26 bit input.
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN
numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm
and the inside buzzer will operate for 10 minutes, depending on the option selected below.
7RGLVDEOHGRRURSHQGHWHFWLRQ)DFWRU\
GHIDXOW
7RVHWWKHDODUPRXWSXWWLPHPLQXWHV
Factory default is 1 minute
7
6 0 #
To enable door open detection 6 1 #
Alarm output time
5 03 #
Normal status: No keypad lockout or
DODUPIDFWRU\GHIDXOW
7 0 # )actory default setting
Keypad Lockout 7 1 #
Alarm and inside buzzer operate 7 2 #
To remove the alarm
To reset the Door Forced Open warning Read valid card or Master Code #
To reset the Door Open Too Long warning Close the door or Read valid card or
Master Code #
Other manuals for T-AC03
1
Other Retekess IP Access Controllers manuals