Please read the following warranty information thoroughly and retain this document for future use and
reference.
Rigel Technology (S) Pte Ltd ("Rigel") warranties the products against any defect of materials or
workmanship for a period of 1 year from the date of purchase.
Within the warranty period, all defective parts will be repaired and/or replaced free of charge.
To be eligible for free repair and/or replacement, any service work on the product must be undertaken
by Rigel or our approved agents.
Service under this warranty will not affect the warranty expiry date, and any warranty on exchanged
parts or products will end when the warranty expires.
This warranty is only applicable for products properly installed and operated in accordance to the
operating procedures stated in the instruction manual.
This warranty does not extend to washroom accessories or other peripheral items.
Rigel's responsibility under this warranty does not apply to damage/defects caused by:
·Misuse, negligence, or accidents.
·Public abuse or vandalism.
·Repairs or alterations not authorized by or performed without consultation from Rigel.
·Repairs or alterations that do not comply with Rigel's installation instruction.
·Repairs or alterations that were not performed with genuine parts supplied by Rigel.
Rigel will not be held liable for any incidental or consequential damages, including loss of profits or
savings, arising from the use or misuse of the products.
The terms in this warranty are only valid after:
·Full payment has been made.
·The official Warranty Card is completely and correctly filled out in ink and returned to Rigel within
14 days of purchase. Loss or misplacement of the Warranty Card, or unauthorized amendments
to the Warranty Card, shall render the warranty null and void.
This warranty is in addition to your statutory and other legal rights.
WARRANTY
1) The installation must comply with the " Requirements for Electrical Installation" commonly
referred to as the IEE Wiring Regulations, or any particular regulations and practices, specified by
the local electricity supply company in force at the time of installation.
2) In accordance with e current edition of "The Plugs and Sockets etc (Safety) Regulations" in force
at the time of installation, the appliance is intended to be permanently connected to the fixed
wiring of the electrical mains system
3) In domestic installation, the rating of the electricity supply company fuse and the consumer unit
must be adequate for the additional demand required for the unit. As this is a high powered unit, it
is essential to contact your electricity supply company to ensure that the existing supply is
adequate for the additional load. Voltage drop due to high local demand will reduce the product
performance.
4) The unit must be earthed by connecting the supply cable earth conductor to the earth terminal.
Within the washroom, all accessible conductive parts of electrical equipment and extraneous
conductive (metal) parts that are likely to introduce earth potential, must be electrically bonded to
earth using a minimum 4mm² cable if unprotected and 2.5mm² cable if protected.
5) To obtain full advantage of the performance from the unit, it is advisable to have the shortest
possible route for the cable from the consumer unit to the product. Long cable runs will increase
the voltage drop and affect the performance of the unit. The maximum permissible length is
dependent upon current demand, voltage drop and cable size, refer to IEE Wiring regulations for
further information.
6) The current rating to the cable will be reduced if it is bunched with other cables, surrounded by
thermal loft or wall insulation or placed in areas where the ambient temperature exceeds 30°.
Under these conditions, de-rating factors apply and it is necessary to select a larger cable size.
7) In the majority of installations, one or more of the above conditions will apply and it is
recommended that a 10mm² cable be installed. The minimum recommended cable size in ideal
conditions is 6mm².
8) A separate, permanently connected supply must be taken from the consumer unit through a
double pole switch, which has at least 3mm minimum contact gap. The switch may be a ceiling
mounted pull cord type within the washroom or a wall mounted switch in an adjacent room.
9) A 30mA residual current device (RCD) must be fitted. This may be a part of the consumer unit or
a separate unit.
10) The product circuit must be protected by either a miniature circuit breaker (MCB) or cartridge fuse
of rating 10 amps installed at the Consumer Unit or Fuse Board.
11) When installing the cable, individual cores must not be twisted before entering the terminal block.
Care should be taken that no strains are exerted on the terminal block when connected to the
cable cores. Ensure all connections are tight to prevent overheating.
12) Do not turn on the electrical supply until the installation is complete and the unit is ready to be
operated.