manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ring Rescue
  6. •
  7. Medical Equipment
  8. •
  9. Ring Rescue CompressionDevice Product manual

Ring Rescue CompressionDevice Product manual

This manual suits for next models

1

Other Ring Rescue Medical Equipment manuals

Ring Rescue Ring Rescue User manual

Ring Rescue

Ring Rescue Ring Rescue User manual

Ring Rescue Compression Device User manual

Ring Rescue

Ring Rescue Compression Device User manual

Popular Medical Equipment manuals by other brands

Itamar Medical WatchPAT Operation manual

Itamar Medical

Itamar Medical WatchPAT Operation manual

PROTEOR 1P650 KNEE Assembling and adjustment instructions

PROTEOR

PROTEOR 1P650 KNEE Assembling and adjustment instructions

Liberate Medical VentFree user manual

Liberate Medical

Liberate Medical VentFree user manual

Dicarre DA20 user guide

Dicarre

Dicarre DA20 user guide

Stryker Medical M Series Operation manual

Stryker Medical

Stryker Medical M Series Operation manual

Invacare ScanBed 750 user manual

Invacare

Invacare ScanBed 750 user manual

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Getinge

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics Sonicator 730 Maintenance manual

Mettler Electronics

Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care R1100 Mounting instruction

Pressalit Care

Pressalit Care R1100 Mounting instruction

Denas MS DENAS-T operating manual

Denas MS

Denas MS DENAS-T operating manual

bort medical ActiveColor quick guide

bort medical

bort medical ActiveColor quick guide

AccuVein AV400 user manual

AccuVein

AccuVein AV400 user manual

agiliti NP Trio user manual

agiliti

agiliti NP Trio user manual

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Rocket Medical

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Monteris Medical Neuroblate Instructions for use

Monteris Medical

Monteris Medical Neuroblate Instructions for use

Otto Block 8E33 7 manual

Otto Block

Otto Block 8E33 7 manual

ADVANCED HOME CARE Helios Guide

ADVANCED HOME CARE

ADVANCED HOME CARE Helios Guide

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Ring Rescue® | CompressionDevice™
RDC01-P003-V1EN
Product Overview
AGauge Face
B Hose
C Pressure Indicator Needle
D Suggested Pressure Zone
E Pressure Relief Valve
F Bulb
G Internal Bladder
H Finger Cuff
RDC01-P003-V1ringrescue.com 4
EN
Specifications
Warning
ALWAYS consult labeling that accompanies accessories for instructions on proper use and storage.
Caution
ALWAYS store this equipment within the specified environmental limits described in this manual.
Note
Specifications are approximate and may vary between devices
Model: Ring Rescue® Compression Device™ RDC-A1-UC
Mass: 0.23 KG (0.51 lb)
Maximum Finger Diameter: 25.5 mm (1.0 in)
Environmental Conditions: Operation Transportation and Storage
Ambient Temperature Limitation
Relative Humidity
Atmospheric Pressure
RDC01-P003-V1ringrescue.com 5
Technical Reference Manual
A B
C D EF H
G
EN
Ring Rescue® | Compression Device™
RDC-A1-UC
FEI Number: 3015542886
Health Canada MDEL Number: 9115
US Patent: 10,702,282
Ring Rescue Inc.
20 Orion Court
Dartmouth, Nova Scotia
Canada
B2Y 4W6
1 (888) 640-7464
ringrescue.com
Made In Canada with domestic and imported parts
RDC01-P003-V1ringrescue.com 1
EN
submerge any components in liquid. Keep device out of direct sunlight or ultraviolet light.
It is recommended a medical glove be applied over the affected hand during device use to preserve cleanliness.
Tutorials
Scan the QR code or visit the link below for Ring Rescue®Compression Device™ instructional
videos:
ringrescue.com/tutorial
Product Expiry
Consult the product label, located on the backside
of the gauge face, for device manufacture and
expiry information.
Warranty
When operated and maintained according to all
instructions supplied, if the Ring Rescue®
Compression Device™ fails due to a defect in
material or workmanship within one (1) year from
the date of original retail purchase, the product
will be repaired or replaced at the option of Ring
Rescue Inc. for no additional charge. This warranty
does not cover unsuccessful ring removal
attempts. For full details see
www.ringrescue.com/warranty
RDC01-P003-V1ringrescue.com 3
EN
Introduction
This Technical Reference Manual represents the most up-to-date knowledge pertaining to the safe and effective use of the Ring Rescue® Compression Device™. This manual is intended to be used by trainers, nurses, physicians, and technicians. Always keep a reference of this manual available for consultation during the life of
the product. Before using this product, please consult the provided Quick Start Guide and become familiar with its operation by watching the instructional videos at:
ringrescue.com/tutorial
or by scanning the QR code below and watching the instructional videos.
Background
The Ring Rescue® Compression Device™ uses
air pressure to temporarily compress a swollen
finger, allowing for the removal of an entrapped
finger ring. Ring removal techniques are then
needed to remove the ring.
Indications for use
The Ring Rescue® Compression Device™ is
indicated for use when a ring is stuck on a finger
(ring entrapment), and removal is desired. The
device, along with correct ring removal
techniques, will often enable the removal of stuck
rings.
Directions for use
Before using this product, please consult the Ring
Rescue® Compression Device™ Quick Start Guide
as well as the instructional videos available at:
ringrescue.com/tutorial
Contraindications For Use
Do not use in cases of severe finger injury.
Definitions
The symbols located on the equipment and/ or
labeling are defined in this section or in the
Symbol Definition Chart. See the Symbol
Definition Chart supplied with the equipment.
Symbol Definition
General warning sign
Read instructions before use
Caution
Do not exceed 15 minutes of total compression
time. Seek qualified medical advice in cases
where finger bone fracture, nerve/vascular injury,
skin laceration or damage, or injured ligaments
and tendons are suspected.
Warning
Use only Ring Rescue® approved accessories and
components (such as Ring Rescue® Ring
Lubricant™) with this product. DO NOT modify
this product or its accompanying accessories in
any way. Modifications to this device or its
accessories will void the warranty and may cause
damage or harm.
Cleaning Instructions
Before and after each use, clean the device and its
components with 70% alcohol or 0.5% accelerated
hydrogen peroxide wipes. Do not use any other
cleaning substances or chemicals. Do not
RDC01-P003-V1ringrescue.com 2