Rinnai Control R User manual

Copyright © 2018 Rinnai America Corporaon. All Rights Reserved. Page 1
❶
This guide is designed to help you quickly install the push buon for on-demand recirculaon with Rinnai SENSEI™ tankless
water heaters using a dedicated return line in the plumbing system.
❷
Place magnec back panel to
side of water heater
(indoor water heaters only).
❸
Unplug water heater power cord from power outlet.
If module comes with spade end
connectors, cut spade end connectors o
the two module wires.
Next, strip insulaon o both ends.
IMPORTANT
• Maximum distance from module to push buon is 250 . (76 m).
• Addional wiring can run up to 300 feet (91 m) away from water heater (18-22 gauge wire required).
• Up to 30 push buons are supported per module.
Push Buon(s)
Control-R™ Module
Water Heater Controller Cable
(included in water heater packaging)
2 Wire Nuts (or other approved
wire connectors) (Field-supplied)
Phillips Head Screwdriver
(Field-supplied)
Wire Cuers/Stripper (Oponal)
(Field-supplied)
Connect module wires to PC Board located inside water heater by compleng steps a, b, and c below.
Remove water heater front panel (use a Phillips Head screwdriver to remove 4 screws securing the panel).
Refer to Push Buon Installaon
Instrucons supplied with module
for wall installaon instrucons.

Copyright © 2018 Rinnai America Corporaon. All Rights Reserved. Page 2
❸
Connect module wires to water heater
controller cable (included in water heater
packaging) using wire nuts or other approved
wire connectors.
Connect controller cable to PC Board through grommet portal on boom, right side of water heater.
Plug water heater power cord into a power outlet.
Connue with next step.
Connect cable
to PC Board.
Insert controller cable through grommet portal
on boom, right side of water heater.

Copyright © 2018 Rinnai America Corporaon. All Rights Reserved. Page 3
Make sure water heater is plugged into power outlet.
Wait for module LED to turn RED.
While you are waing, connue with next step.
RED
Press/hold down push buon and insert two supplied baeries at the same me. Ensure + (plus)
terminals are aligned correctly.
When baeries are installed, release the push buon.
Press and hold down Connect buon on MODULE
unl LED turns GREEN.
Then, release buon.
• Press and hold down push buon.
• Push buon ashes three mes and then rapidly ashes.
• Release push buon.
❹
Insert push buon baeries by following steps a, b and c below.
Press both sides. Li and remove cover.
Insert baeries
+ (Plus) terminals
Replace cover on push buon (cover ts in one direcon only).
GREEN
PRESS AND HOLD
You have ve minutes to complete the following three
bullets:
Press, then li UP cover.

Copyright © 2018 Rinnai America Corporaon. All Rights Reserved. Page 4
If paired successfully, module LED quickly blinks GREEN
and turns RED.
❹
RED
Press push buon.
Module LED quickly blinks GREEN and turns RED.
RED
Set a mer for 5 minutes.
While waing, connue with
next secon.
5
Press On/O buon on controller to turn OFF water heater.
❺
IMPORTANT
Controller MUST be turned OFF for remaining
steps to work correctly.
IMPORTANT: Aer pressing push buon, DO NOT press it again unl 5-minute mer is
complete (as explained in next step).
(This signies
communicaon between
push buon and module.)
Press and hold down A buon on PC Board for 1 second.
The controller turns ON.

Copyright © 2018 Rinnai America Corporaon. All Rights Reserved. Page 5
Press Up arrow unl 04A appears in display.
04A
Press On/O buon on water heater controller to
turn ON water heater.
❺
Press On/O buon unl 04 appears in display.
Press Up arrow unl 05A appears in display.
05A
Comfort mode is selected.
To select addional parameters, see Appendix A.
When parameter sengs are complete, press and
hold down A buon on PC Board for one second to
exit parameters. The controller turns OFF.
Replace water heater front panel.
COMPLETE REMAINING STEPS ONLY AFTER
5-MINUTE TIMER IS FINISHED FROM STEP 8 ON
PAGE 4.
ON
Press push buon. Module LED blinks GREEN and
pump turns on.
GREEN
Instrucons for pairing one push buon are
complete.
To pair addional push buons, follow the steps
below.
• Press On/O buon on water heater controller to turn
OFF water heater.
• Unplug water heater power cord from outlet and then
plug it back in.
• Repeat steps 3-6 from pages 3 and 4.
• Press On/O buon on water heater controller to turn
ON water heater.
• Press push buon. Pump turns on.
Press On/O buon unl 05 appears in display.
05

Copyright © 2018 Rinnai America Corporaon. All Rights Reserved. Page 6
100000634
10/2018
Parameter sengs can be set with the
water heater turned OFF.
TIP
1. Press On/O buon on controller to turn OFF water
heater.
2. Press A buon on PC Board for 1 second.
3. Press Up arrow unl 03A appears in display.
4. Press On/O buon unl the following appears in
display:
• 03A
• 03
• 03C
• 03
5. To exit parameter sengs, press and hold down
A buon on PC Board for 1 second.
1. Press On/O buon on controller to turn OFF water
heater.
2. Press A buon on PC Board for 1 second.
3. Press Up arrow unl 02A appears in display.
4. Press On/O buon unl the following appears in
display:
• 02A 0 to 2,000
• 02 2,001 - 5,400
• 02C 5,401 - 7,700
• 02 7,701 - 10,200
5. To exit parameter sengs, press and hold down
A buon on PC Board for 1 second.
Disabled
0.5 Year
1 Year
2 Years
1. Press On/O buon on controller to turn OFF water
heater.
2. Press A buon on PC Board for 1 second.
3. Press Up arrow unl 04A appears in display.
4. Press On/O buon unl the following appears in
display:
• 04A
• 04
5. To exit parameter sengs, press and hold down
A buon on PC Board for 1 second.
No Recirculaon
Dedicated Mode
IMPORTANT
Refer to “Rinnai Tankless Water Heater
Installaon and Operaon Manual” for complete
list of water heater parameter sengs.
Table of contents