1. Check you have the correct enclosure and tray. Please look at the labels on the side of the product packaging.
2. Check all the product components are in the box and the fixing kits are complete. Please check this with the component check list overleaf.
3. Un Pack your product and handle it with care.
4. Please check the product for defects or damage. Once the installation has commenced we cannot accept responsibility for any defects or
damage to the products.
5. Please take the time to read these instructions prior to installing your product.
6. Before you commence any drilling check there are no hidden electrical cables and/or water pipes in the walls.
7. No attempt should be made to re-work the toughened safety glass.
8. The installation should be performed by two persons.
9. It is strongly recommended the walls the product is going to be installed on are vertical. However the wall profiles have 25mm of adjustment
to help compensate for some deviation.
10. It is strongly recommended the product is fitted on tiled surface or similar waterproof surface.
11. It is strongly recommended the walls are tiled and grouted after the installation of the tray and before the installation of the product. This will
provide maximum adjustment and help when sealing the product.
12. If the walls and/or the tray are not level you will not achieve maximum adjustment of the product.
13. Pictures used are for illustration purposes only, product designs may alter slightly as a result of continuing product development.
14. We do not stipulate where the European Standard Kite Mark should be positioned on the glass panels
when being factory assembled.
IMP RTANT INF RMATI N
• Roman’s toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed
according to our guidelines.
• It is important to note, that the glass must not be mounted or ‘pinched’ in such a way that would cause a stress point to develop in the
glass. In addition, it must not be subjected to any sharp impact or severe temperature fluctuation which may also cause a stress point to
develop in the glass.
• Roman’s toughened glass is physically and thermally significantly stronger than standard glass. During our toughening process the
stresses contained within any glass are balanced so if in the unlikely situation any of the above occurs and the glass breaks, the glass will
shatter safely into small thumbnail sized blunt fragments.
IMP RTANT PRE-INSTALLATI N CHECKS
IMP RTANT: IF Y U ARE FITTING THIS PR DUCT WITH INTEGRATED WATER DELIVERY, THE VALVE MUST BE INSTALLED
BEF RE TILING THE SH WERING AREA AND BEF RE THE INSTALLATI N F THIS PR DUCT.
FC
Consumer Guarantee - Please make sure the purchaser/end user completes and returns the Guarantee card
which is enclosed with this product. Failure to validate the Guarantee will mean only the 1 Year Statutory Guarantee will apply.
FC:CQB 4/5/10 12:13 Page 1

IMP RTANT PRE-INSTALLATI N CHECKS
1. Check the tray is level, on all sides (The bubble should be in the centre of the two lines on the spirit level).
2. Stand in the tray and check there is no adverse movement.
3. The walls should be tiled and grouted prior to installing the enclosure.
4. The tiles and the tray should be sealed, using bathroom sealant.
• Spray the seal and joints with the shower head and check for leaks.
• Check the plumbing for leaks.
• Do not grout the tiles when the enclosure has been fitted as the grout may discolour the aluminum profiles.
• Make sure the tray is installed as per the manufacturers instructions.
• When all of the above criteria is complete please proceed to the next step in these instructions.
Step 1 - Checking the tray
Component Check List: Supplied
Description Quantity
FC13 FCG13
Curved Panel 11
Side Panel 1
Wall Profiles 12
Wall Profile Trims 12
Brace Bar Assemblies 11
Fixing Kit - Component Check list.
40mm Screws 47
Wall Plugs 47
16mm Pan Head Screws 36
Branding Badge (where applicable) 11
Profile Cover Caps 24
2.5mm Allen Key 11
3mm Allen Key 11
3mm Drill Bit 11
ocation Pin 11
Equipment Check List: Not Supplied
Description
Mains or battery drill.
6mm masonry drill bit.
Bathroom sealant gun.
Bathroom sealant tube.
Pozi Screw driver.
Flat Head Screw Driver.
Spirit levels.
Tape measure.
Pencil.
Additional fixings if going into plaster board.
FC:CQB 4/5/10 12:13 Page 2

Step 2 - Fixing the Wall Profiles.
Fix Wall Profile: 1
1. Position the wall profile using the guide on the tray. The lip of the profiles face towards the inside of the enclosure (look at
point 2 above).
• The wall profiles must be vertically level, check using a spirit level. (The bubble should be in the centre of the two
lines on the spirit level).
2. Mark the locations for the drill holes using a pencil.
• Use the supplied wall plugs if fixing the wall profiles into brick or block work, if fixing into plaster board, the
appropriate fixings will need to be used.
3. Drill the holes using 6mm masonry bit (not supplied). Then push the wall plugs in beyond the depth of the tile
4. Apply sealant the width of the wall profile, at the bottom where it meets the wall and the tray. (Important: failure to carry
out this procedure can cause serious water damage and is not covered by the guarantee).
5. Fix the Wall Profile using the 40 mm screws (supplied).
6. Apply Sealant to the inside of the wall profile, where it meets the tray. (Important: failure to carry out this procedure can
cause serious water damage and is not covered by the guarantee).
Fix Wall profile: 2
7. Follow points 1 - 6 to fit wall profile 2, except take the 20mm measurement for the profile location (point 7).
Info:
• (If you are fitting the enclosure straight to floor see the guidance page at the back of these instructions).
FC:CQB 4/5/10 12:13 Page 3

Step 3 - Fix the Curved Panel (and end panel if applicable)
1. Remove the black transit caps from all the glass panels.
2. Screw the location pin into the curved profile that is assembled onto the large curved piece of glass.
3. Offer the Curved panel into location in the wall profile and position the location pin into the hole in the tray.
4. Drill through the pre-drilled holes of the wall profile using a 3mm drill bit.
5. Fix the panel into wall profile using the supplied 16mm pan head screws.
6. Offer the Side panel into location on the tray and in the wall profile; make sure the glass is running parallel to the
side of the tray, and is sitting horizontally along the tray. (Fix side panel repeating points 4 and 5).
• (If you are fitting the enclosure straight to floor see the guidance page at the back of these instructions).
• (You may need help to perform the installation steps, particularly to lift and hold the glass panels in location).
(Pease ensure the transport bands are removed with care from the glass panels in this and the following steps.)
FC:CQB 4/5/10 12:13 Page 4

1. Disassemble the panel side location cup, and screw the brass insert into the profile on top the curved glass panel, then re-
assemble the cup onto the brass insert. Don't tighten the allen key yet.
2. Determine the location of the wall cup using the full brace bar assembly. Push the brace bar into location in the panel cup
and slide the wall cup on the other end, mark the location using a pencil.
• Make sure the brace bar is level. (The bubble should be in the centre of the two lines on the spirit level).
3. Remove the brace bar and unscrew the brass insert from the wall cup. Hold the insert concentric to the pencil mark and
mark the drill hole location.
4. Drill the location hole using a 6mm masonry drill bit and insert the wall plug.
5. Fix using a 40mm screw and then screw the wall cup onto the brass insert and tight up to the tiles.
6. Re-assemble the bracing bar into the panel side cup and the wall cup.
7. Tighten all the grub screws in the wall and panel cups using an Allen key when you are satisfied the brace bar has been
adjusted correctly.
- There is 25 mm of adjustment in the brace bar to allow correct alignment.
- The brace bar must be level (The bubble should be in the centre of the two lines on the spirit level).
- The Front Panel must be vertically level, make sure the brace bar is adjusted to achieve this.
(The bubble should be in the centre of the two lines on the spirit level).
Step 4 - Assemble the Brace Bar.
FC:CQB 4/5/10 12:13 Page 5

1. Clip on the wall profile cover trims. (They are designed to be a tight fit so take care).
2. Place all the cover caps on the profiles. (R and on the inside of the caps indicate the handing of the caps looking from
the outside of the enclosure)
3. Stick on the Roman Branding Badge.
4. Seal vertically the full length of the wall profiles/wall profile trims where they meet the tiles on the inside of the
enclosure, using bathroom sealant. Also seal vertically the full length of the wall profiles where they meet the tiles on
the outside of the enclosure, using bathroom sealant.
5. Seal horizontally the aluminum profiles and the glass panels on the outside of the enclosure, at the bottom where they
meet the tiles and the tray, using bathroom sealant..
• (Please leave the sealant 24 hrs to cure before use).
IMP RTANT:Failure to carry out the procedure in Steps 4 & 5 can cause serious water damage and is not
covered by the guarantee.
• If you are fitting the enclosure with integrated water delivery, please refer to your valve instructions to complete
the installation.
Step 5 - Fix the Cover Caps and Seal the Enclosure
FC:CQB 4/5/10 12:13 Page 6

Item No. Part Number Colour Description Length (mm) QTY
1 ROGWPS Silver Wall Profile 1900 2
2 ROG02S Silver Screw Cover Trim 1900 2
3 ROF01S Silver Vertical Frame 1900 1
4 ROF02S Silver Offset Vertical Extrusion 1900 1
5 ROF03S Silver Circular Profile 1900 1
6 OF01 Clear 8mm Toughened Glass 1899 x 575 x 8 1
7 OF02 Clear 6mm Curved Panel Glass 1
8 ROF12 Silver 19mm Curved Brace Bar 1
9 RMC0074 Silver Brace Joint 1
10 RMC0075 Silver 19mm Wall Joint 1
11 RIM0206 Chrome Vertical Cover Cap (R-H) 1
12 RIM0210 Chrome Screw Cover Cap (R-H) 1
13 RIM0211 Chrome Screw Cover Cap ( -H) 1
14 RIM0207 Chrome Vertical Cover Cap ( -H) 1
15 RSCR48 White Plastic Tray Pin 20 1
Spare Parts: If you need to replace any damaged parts please see illustration below for parts
list then call Customer Services on 01325 328034.
Should you experience any problems during installation please refer to the
Trouble Shooting Guide or contact Customer Relations on:
+44 (0) 1325 328033/328034
To enable customer relations to provide you with an excellent level of service it is important that you quote your
Product Code and Reference Number - these numbers can be found on the guarantee card.
FC:CQB 4/5/10 12:13 Page 7

Locating the wall profiles and using the
panel location pin (steps 2 and 3).
The measurements left need to be used to
locate the wall profiles (step 2).
The location pin measurements left need to
be used to locate the glass panel (step 3).
1. In order to use the location pin follow the
measurements (left) to determine the
position.
2. Drill an 9mm diameter hole with a
recommended depth of 10mm, using
suitable a drill bit.
3. Screw the location pin into the bottom of
the curved profile on the large curved
glass panel.
4. Continue with the installation by
following the instructions.
Caution:
Before you commence any
drilling check there are no hidden
electrical cables and/or water pipes
under the floor and make sure you have
enough depth in the floor to locate the
pin. Do not puncture the wet room
membrane during the drilling. If you are
unsure about the installation seek
professional advice.
Straight to floor guidance:
Some important information to help you Maintain your product.
The following information is all you need to keep your product looking new.
Clean your product using a mild detergent diluted in water and then polished off using a soft cloth.
If you live in a hard water area, periodically clean your product using a 50/50 solution of white vinegar and water. The solution
should be left on the enclosure for approximately 5 minutes then rinsed off using warm water. This method of cleaning should
remove lime scale residue.
Simple maintenance.
Our products are generally maintenance free, however it may be necessary to lubricate wheel assemblies and other moving parts
from time to time.
It is strongly recommended that a quality silicone spray is used.
A list of Don'ts:
1 - Don't use acidic based products which are unsuitable for cleaning enamel surfaces.
2 - Don't use Abrasive cleaners or cleaners containing bleach or solvents, these products will adversely affect the finish of the
aluminium profiles.
3 - Don't use scouring pads, powder or any sharp instruments when cleaning the enclosure.
TR UBLE SH TING GUIDE.
Problem Solution
LEAKING 1. Check the enclosure has been sealed correctly as per the instructions:
2. The width of the wall profiles at the bottom where they meet the wall and the tray (Step 2).
3. Inside the wall profiles where they meet the tray (Step 2).
4. Vertically on the inside of the enclosure the full length of the wall profile/wall profile trims,
where they meet the tiles (Step 5).
5. Vertically on the outside of the enclosure the full length of the wall profiles where they meet the tiles (Step 5).
6 Horizontally along the glass and aluminium on the outside only (Step 5).
ENCL SURE 1. Check the wall profiles have been installed as per the instructions: Make sure they are vertically level (Step 2).
ALIGNMENT 2. Check the tray installation (Step 1).
N TRAY 3. Check the brace bar has been installed as per the instructions. Check the brace bar is level. Check the panels
are vertically level (Step 4).
FC:CQB 4/5/10 12:13 Page 8
This manual suits for next models
1
Table of contents
Other Ro-Man Shower Cabin manuals
Popular Shower Cabin manuals by other brands

Aston Global
Aston Global SEN980-36-8-L Installation and owner's manual

Cello
Cello Lawrence 80 x 80 instruction manual

OVE
OVE OWS-106 Installation and user guide

RIHO
RIHO SCANDIC NXT X109V installation manual

RAVAK
RAVAK GSRV4-200 Assembly instructions

MASCO Bath
MASCO Bath Aqua Glass ASB Eleganza 48" installation manual

AM.PM
AM.PM BLISS L TWIN SWING manual

KOLO
KOLO AKORD SWING manual

glass 1989
glass 1989 SOHO QR Installation & maintenance manual

American Bath Factory
American Bath Factory Sistine Stone Corner installation guide

Bathlife
Bathlife Betrakta BL-960470 Install manual

Allen + Roth
Allen + Roth Ellum 32 installation manual