Rockwell Automation Publication 442G-IN004C-EN-P - January 2020 7
Multifunctional Access Box with CIP Safety over EtherNet/IP
Specifications
Declaration of Conformity and Certification
For the latest certificate, see rok.auto/certifications.
Additional Resources
You can view or download publications at rok.auto/literature.
Table 8 - Safety Ratings
Standards
IEC 60947-5-3, EN ISO 13849-1, ISO 14119, UL 508 (evaluated for
risks of electrical shock and fire; only suitable for NFPA 79
applications)
Safety Classification Type 4 interlocking device with guard locking and high-coded RFID
actuators according to ISO 14119
Functional Safety Data
PLe, Cat. 4 (according to ISO 13849-1)
MTTFd
Monitoring of guard locking 746 years
Control of guard locking 475 years
Evaluation of emergency stop 787 years
Evaluation of enabling switch 753 years
PFHd
Monitoring of guard locking 3.37 x 10-9
Control of guard locking 4.91 x 10-9
Evaluation of emergency stop 3.05 x 10-9
Evaluation of enabling switch 3.05 x 10-9
B10d:
Emergency stop 1.0 x 105
Enabling switch
According to
manufacturer
specifications
Mission time 20 years
Certifications c-UL-us (UL 508) and CE Marked for all applicable EUdirectives
Safety Outputs CIP Safety
Table 9 - Operating Characteristics
Torque Settings, max
• Lock module cover screws (6x): 1 N•m (8.85 lb•in)
• Manual release locking screw: 0.5 N•m (4.42 lb•in)
• Handle set screw (handle and escape release): 2 N•m (17.70 lb•in)
Holding Force Fzh (ISO 14119) 2000 N
Locking Bolt Alignment Tolerance Horizontal: ±4 mm (0.16 in.); Vertical: ±5 mm (0.2 in.)
OperatingVoltage Class 2 PELV 24V DC +10/-15% required (2)
(2) See Power Supply Requirements on page 2.
EMC Protection Requirements In accordance with EN 61000-4 and DIN EN 61326-3-1
Current Consumption, maximum 500 mA
Power Connector Rating 4 A (IEC 61076-2-101:2013) maximum value
External Fuse Minimum 1 A, slow-blow
EMC Protection Requirements In accordance with EN 61000-4 and DIN EN 61326-3-1
Risk Time (per IEC 60947-5-3) (1)
(1) The risk time is the maximum difference between the time the input status changes and the time the
corresponding bit in the input assembly is turned on.
• E-stop: 100 ms
• Enabling switch: 100 ms
• Guard position: 250 ms
• Bolt position: 250 ms
• Guard locking: 250 ms
Switching Frequency, maximum 1 Hz
InsulationVoltage Ui (IEC 60947-1) 75V
Impulse Withstand Voltage Uimp 0.5 kV
Pollution Degree (IEC 60947-1) 3
Manual Release Built-in (ISO 14119)
Mechanical Life 1,000,000 operations
Table 10 - Environmental
Ambient Temperature at
UB = DC 24V -20…+55 °C (-4…+131 °F)
StorageTemperature -20…+65 °C (-4…+149 °F)
Enclosure Rating IP54
Operating Humidity 5…80% relative
Vibration/Shock IEC 60068-2-27 30 g (1.06 oz), 11 ms/IEC 60068-2-6
10…55 Hz
Table 11 - Physical Characteristics
Weight
• Lock/bus assembly on mounting plate: 3.6 kg (7.9 lb)
• Handle assembly on mounting plate: 1.2 kg (2.6 lb)
• Escape release 500 g (17.6 oz)
Materials Glass fiber reinforced plastic, nickel-plated die-cast zinc, anodized
aluminum handle, stainless steel, powder-coated sheet steel
Resource Description
Multifunctional Access Box with CIP Safety
Over EtherNet/IP User Manual, publication
442G-UM002 (translations available)
Provides information for the design,
installation, programming, or
troubleshooting of systems that use the
multi-functional access box.
Industrial AutomationWiring and Grounding
Guidelines, publication 1770-4.1
Provides general guidelines for installing a
Rockwell Automation® industrial system.
Product Certifications website:
rok.auto/certifications
Provides declarations of conformity,
certificates, and other certification details.