Rockwell Automation Allen-Bradley GuardShield 450L-B4FN YD... User manual

Installation Instructions
Original Instructions
GuardShield Safety Light Curtain
Catalog Numbers 450L-B4FNxYD, 450L-B4HNxYD, 450L-E4FLxYD, 450L-E4HLxYD
A 450L GuardShield™ safety light curtain system is intended to be part of the
safety-related control system of a machine. Before installation, a thorough risk
assessment must be performed to determine whether the specifications of this
device are suitable for all foreseeable operational and environmental
characteristics of the application.
Installation must be in accordance with the publication 450L-UM001 and
implemented by qualified personnel exclusively.
Figure 1 - Package Content
Installation
Figure 2 - Remove Red Slot Cover
Figure 3 - Check DIP Switches on Connection Plug-in
Figure 4 - Insert Plug-in
If a 450L-E safety light curtain is used and operated with a cascading plug-in,
remove the gray slot cover insert and mount the cascading plug-in similar to the
connection plug-in.
Figure 5 - Tighten Screws
Figure 6 - Install Mounting Kit
WARNING: The following applications and/or environmental
conditions can lead to misuse and potentially cause severe
injuries or death (for more information see IEC 62046):
• Machines that eject materials, swarf, or component parts
• Risk of injury from thermal or other radiation
• Unacceptable noise levels
• Transparent objects are detected
• An environment that exceeds the specification, limits provided
in publication 450L-UM001.
Some but not all possible limits are electrostatic discharge,
radio frequency interference, vibration/shock, ambient light,
pollution, temperature, humidity.
The 450L GuardShield safety light curtain cannot be used with
machines that cannot be stopped electrically in an emergency.
ATTENTION: Without additional measures (IEC 62998),
GuardShield 450L-B safety light curtains are not designed to
be used for the following applications:
• Outdoors
• Under water
•Explosiveatmospheres
• Altitudes over 3000 m (1.86 miles) above sea level
• With enhanced ionizing or radar radiation
The protective system must be tested for proper operation
after each change to the configuration.
ATTENTION: This package content is intended for
replacement cases. For new product installation, see
publication 450L-UM001.
Stick
Test Rod
Mounting Kit
ATTENTION: Do not insert or remove plug-ins when power is
applied to the plug-in.
0.38 N•m (3.36 lb•in), Max
0.7 N•m (6.19 lb•in), Max

2Rockwell Automation Publication 450L-IN004B-EN-P - March 2022
GuardShield Safety Light Curtain Installation Instructions
Figure 7 - Positioning of Transmitter and Receiver Sticks
Confirm that both connection plug-ins are at the same end of the installation.
Figure 8 - Install, Connect, Power-up, and Align Complete System
The 450L-E safety light curtain sticks have an integrated laser alignment system.
Place a finger on the optical switch (the square next to the hand symbol on the
front window) to switch the alignment system on and off.
Figure 9 - Use the Integrated Laser Alignment System for Positioning
For 450L-B safety light curtain sticks, an optional laser alignment tool
(catalog number 440L-ALAT) and clamp (catalog number 450L-ALAT-C) are
available.
Figure 10 - Test Resolution with Test Rod
Verify that while the test rod is anywhere within the protective field, the OSSD
safety outputs remain in the off-state. Move the test rod as indicated in Figure 10
with a maximum speed of 0.3 m/s (11.8 in/s). Be sure that the intensity indicator
indicates a continuous protective field interruption (minimum one intensity
indicator is off).
ATTENTION: Damage occurs to the safety light curtain when
screws are overtightened. To avoid pollution or contamination,
the implement the installation of a plug-in into a stick in a dry
and clean area. Verify that the rubber seal at the plug-in does
not shift out of place when the plug-in is inserted in the safety
light curtain.
ATTENTION: Do not stare into the beam. Laser Class 2.
Conforms to 21 CFR 1040.10.
Power
Power Power Power
Laser Optical Switch
ATTENTION: Always maintain the required safety distance
(see publication 450L-UM001) between the 450L GuardShield
safety light curtain and a dangerous machine movement.
Additional mechanical protective devices must be installed if
hazardous machine elements can be reached without passing
through the protective field. Improper installation can result in
serous injury or death. Never connect the safety outputs
(OSSDs) to +24V DC.
The Auxiliary output is only a status output for diagnosis
purposes to connect, for example, an indicator lamp. Do not
connect this output to fulfill safety functions. If the safety
outputs are connected to +24V DC, they are in the on-state and
cannot stop hazardous machine/application movements.
Do not open or attempt to repair or modify the
450L GuardShield safety light curtain. Removal of either of the
gray GuardShield end caps or the transparent front window
voids the warranty terms of this product.
Verify that the power supply is protected against overload
(fuse with 3 A in the 24V DC circuit).

Rockwell Automation Publication 450L-IN004B-EN-P - March 2022 3
GuardShield Safety Light Curtain Installation Instructions
Table 1 - 450L Safety Light Curtain Status Indicators for Normal Operation
Marking
Status
Indicator
Name
Color Behavior Description
STS Status
indicator
Green On Power on and system is OK
Green Red Blinking
Configuration that is changed or
receiver was operated previously with
another transmitter. See publication
450L-UM001.
Green Off Blinking (98:2) Interference rejection is enabled
Green Red Blinking (90:10) Optical interference is detected (this
status is indicated even if interference
rejection is already enabled)
Green Off Blinking
See publication 450L-UM001
Off Red Blinking
Red On
Transmitter Green
On Plug-in identifies stick as a transmitter
Blinking 1 Hz (50:50) See publication 450L-UM001
Blinking 1 Hz (98:2) Reduced range is activated
Off Stick is receiver
Receiver Green On Plug-in identifies the stick as a
receiver
Blinking 1 Hz (98:2) Reduced range is activated
Off Stick is transmitter
OUT Safety
outputs
Green On Safety outputs are on (receiver)
Red On Safety outputs are off (receiver)
Off Transmitter
Regional light
intensity
level 1
Green
On Bottom half zone is not interrupted and
intensity is OK
Blinking 1 Hz (50:50) Bottom half zone intensity is at the
limit
Off Bottom half zone interrupted
Regional light
intensity
level 2
Green On Top half zone is not interrupted and
intensity is OK
Blinking 1 Hz (50:50) Top half zone intensity is at the limit
Off Top half zone interrupted
RES Start Amber On Start required (receiver)
Off No start is required (receiver)
MUT Muting Orang
e
Off Light curtain not
muted
MUTOn Light curtain muted
Blinkin
gMuting error
BLK Blanking Orang
e
Off No blanking feature
selected
BLKOn Blanking feature
selected
Blinkin
gBlanking error
CAS Cascading Red
Off
No cascading plug-
in inserted or Tx or
OSSDs of connected
cascade are in on-
state (Rx only) CAS
On OSSDs of connected
cascade are in off-
state (Rx only)
Blinkin
gPlug-in cascade
error
Table 2 - DIP Switch Functionality
450L-APR-ON-5:
450L-APR-EDM-8:
450L-APU-UN-8:
DIP 1…4
DIP 1…8
DIP 1…12
450L-APR-BL-8:
450L-APR-MU-8: DIP 1…8
DIP 1…12
Switch Number Switch Function Default Description
1— Off—
2 Low range activation Off Off: Disabled
On: Enabled
3Beamcoding(450L-Eonly)Off
Off: Disabled
On: Enabled
4Interference rejection
(450L-E only) Off Off: Disabled
On: Enabled
5
Combination activation of the
following start modes:
• Automatic start
• Manual (re) start
• Manual cold start
• Manual start with off
function
Off
DIP 5: Off,
DIP 6 Off:
Automatic start (Default)
DIP 5: On,
DIP 6 Off:
Manual (re) start
DIP 5: Off,
DIP 6 On:
Manual cold start
DIP 5: On,
DIP 6 On:
Manual start with off function
6Off
7ExternaldevicemonitorOff
Off: Disabled
On: Enabled
8
Muting or blanking
(450L-E only)
Off —
9Off
For details, see publication
450L-UM001
10 Off
11 Off
12 — Off —

Publication 450L-IN004B-EN-P - March 2022 | Supersedes Publication 450L-IN004A-EN-P - December 2017
Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, Guardmaster, GuardShield, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
For technical support, visit rok.auto/support.
PN-306702
10001601201 Ver 02
Waste Electrical and Electronic Equipment (WEEE)
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
CE Marking and EC Conformity
The present product complies with the requirements of the current European and
national directives: 2006/42/EC (Machinery);
2014/30/EU (EMC); 2011/65/EU (ROHS) Conformity has been verified. The
corresponding declaration can be downloaded at rok.auto/certifications. Rockwell
Automation B.V.; Rivium Promenade 160; 2909 LM Capelle aan den ljssel; The
Netherlands.
Additional Resources
To download publications, visit rok.auto/literature and search for the following
publication numbers.
Table 3 - Pin Assignment Connection Plug-in (1)
Plug-type Tx (2) Rx (3) Tx (2) Rx (3) Tx (2) Rx (3)
Pin 450L-APT-PW-5 450L-APR-ON-5
450L-APR-BL-5 450L-APT-PW-8 450L-APR-ED-8 (4)
450L-APR-MU-8 (3) 450L-APU-UN-8
1 +24V DC +24V DC Do not connect Auxiliary output (OSSD emulation) (4) Do not connect Auxiliary output (OSSD emulation)
2 Do not connect OSSD1 +24V DC +24V DC +24V DC +24V DC
3 0V (ground) 0V (GND) Earth PE Earth PE Earth PE Earth PE
4 Do not connect OSSD2 Do not connect EDM (input)(1) (5) EDM (input) (6)
5 Earth PE Earth PE Do not connect OSSD1 Do not connect OSSD1
6
——
Auxiliary output (lockout) OSSD2 Auxiliary output (lockout) OSSD2
7 0V (GND) 0V (GND) 0V (GND) 0V (GND)
8 Do not connect Start (4) (5) Start (4)
(1) For cascading plug-in (catalog number 450L-APC-IO-8), see publication 450LUM001.
(2) Tx=Transmitter
(3) Rx=Receiver
(4) If set with DIP switches.
(5) Pin 4 connected to pin 8 (short circuited).
(6) For muting applications, see publication 450LUM001.
5
4
3
1
2
56
7
8
4
3
1
2
Resource Description
GuardShield Safety Light Curtain
User Manual,
publication 450L-UM001
Provides product-specific guidelines for installing the
Rockwell Automation® 450L-B and 450L-E safety light
curtain system.
450L GuardShield Safety Light
Curtain Quick Start, publication
450L-QS001
Provides a summary of the basic steps that are required
to configure and run a system using 450L light curtains.
Product Certifications website,
rok.auto/certifications Provides declarations of conformity, certificates, and
other certification details.
This manual suits for next models
3
Popular Lighting Equipment manuals by other brands

luminii
luminii Optic Arts PS010TW-96-24 installation instructions

WHITECROFT LIGHTING
WHITECROFT LIGHTING Concert EX3S quick start guide

VISICO
VISICO Elfin Series user guide

ARRI
ARRI L5 Short Instruction

EuroLite
EuroLite VFL-575 user manual

Flash butrym
Flash butrym LED MOVING HEAD 7x10W RGBW 4IN1 user manual

Federal Signal Corporation
Federal Signal Corporation COMMANDER Series instruction sheet

LDR
LDR CETRA F100 CM, 120W LED RGBW, 100/260V,... operating instructions

Ledj
Ledj Slimline Q5 Series user manual

Jacassi
Jacassi JY2101-RT user manual

HauntBots
HauntBots EyeFx operating manual

Good Earth Lighting
Good Earth Lighting G5230-BKSS-I quick guide