RoDEK RFS-20 User manual

1
RDUM-100, Rev.1Rodek Co., Ltd.
User Manual
Lens Dust Filtering System
RFS-20 / RDS-20

2
RDUM-100, Rev.1Rodek Co., Ltd.
Table of Contents
Ⅰ. Foreword............................................................................................................................................................................3
Ⅱ. Summary............................................................................................................................................................................3
Ⅲ. Features..............................................................................................................................................................................3
Ⅳ. Basic Orientation...........................................................................................................................................................4
Ⅴ. Installation ........................................................................................................................................................................5
1. Wastewater tank installation...............................................................................................................................5
2. Filtering equipment installation ........................................................................................................................7
3. Components of Air deodorization equipment and its installation ..................................................9
Ⅵ. How to use the coagulant and the antifoaming agent.......................................................................10
1. Coagulant (AP-20) ................................................................................................................................................10
2. Antifoaming agent (AF-20)...............................................................................................................................12
Ⅶ. Parts...................................................................................................................................................................................14
Ⅷ. Consumables ................................................................................................................................................................15
Ⅸ. Specifications ...............................................................................................................................................................16
Ⅹ. Precautions ....................................................................................................................................................................17

3
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅰ. Foreword
Thank you for purchasing this Lens Dust Filtering System (RFS-20 and RDS-20).
Please read this user manual carefully in order to use this device safely and
efficiently.
Ⅱ. Summary
This device, in conjunction with a lens edger, is used for filtering microplastics
and odors that occur when edging eyeglass lenses.
Ⅲ. Features
· The device can be connected to various lens edgers.
· Compact design: it can be installed in small spaces.
· Simple structure for easy maintenance.
· Removes the odor generated by the edging of lenses using activated carbon
and antifoaming agent.
· Wastewater treatment using pressurized circulation.

4
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅳ. Basic Orientation
①Filtering equipment ⑥Air pocket to filtering equipment hose
②Wastewater Tank ⑦Filtering pump to air pocket hose
③Air deodorization equipment ⑧Wastewater tank air outlet
④Power supply box ⑨Filtering equipment base
⑤Air pocket ⑩Wastewater inlet

5
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅴ. Installation
1. Wastewater tank installation
1) Place the filtering equipment base in the desired location.
2) Install the wastewater tank as follows:
2-1) Place the wastewater tank on the filter base and fill it with water
up to the marker.
2-2) Assemble the Air deodorization equipment hose connector on
the filtration tank cover.
2-3) Assemble the filtering pump.
2-4) Assemble the rest of the parts as follows:
2-4-1) Secure the wastewater tank mesh filter to the
wastewater tank cover top panel. Do this by aligning
the bolts on the wastewater tank filter to the
corresponding holes on the wastewater tank cover
top panel. Secure using the provided nuts.
2-4-2) Bolt the wastewater inlet port onto the filtration
tank cover top panel.

6
RDUM-100, Rev.1Rodek Co., Ltd.
○1 Wastewater tank ○5E A Mesh filter
A○2E A Filtering pump A○6E A Wastewater tank cover top panel
A○3E A Wastewater tank air outlet A○7E A Wastewater inlet
A○4E A Wastewater tank cover A○8E A Diffuser

7
RDUM-100, Rev.1Rodek Co., Ltd.
2. Filtering equipment installation
1) Place the stainless-steel wire mesh filter at the bottom of the inside
of the filtering equipment.
2) Check the dimensions of the plastic mesh filter and place it inside
the filtering equipment as shown in the figure.
2-1) The plastic mesh filter is an isosceles trapezoid. The longer of the
two parallel sides should be the top side during insertion.
3) Place the filter (RFS-20F) inside the filtering equipment. See to it that
the filter closely conforms with the inside of the filtering equipment.
4) Lock the filter in place by inserting the locking ring inside the filter
as shown in figure 4.
5) When you insert the locking ring, do not block the wastewater inlet located
at the top of the filtering equipment. Fold the portion of the filter that is above the
locking ring downward into the inside of the filter.
6) When you insert the filter, the bottom of the filter should reach the
stainless-steel wire mesh filter that you placed in step 1 above.
7) Close the lid of filtering equipment and tighten the locking
mechanism clockwise.

8
RDUM-100, Rev.1Rodek Co., Ltd.
<1> <2>
<2-1> <3> <4>
<5> <6>
<7>

9
RDUM-100, Rev.1Rodek Co., Ltd.
3. Components of Air deodorization equipment and its installation
1) Install the Air deodorization equipment as shown in the following
picture. Place the Primary Filter →Activated carbon box →A.V Filter
→HEPA Filter on top of the deodorization filter assembly support
inside the deodorization equipment.
①Deodorization Fan
②HEPA Filter
③A.V Filter
④Activated carbon box
⑤Primary Filter
⑥Primary Filter frame
⑦
Deodorization
equipment body
⑧Air Inlet

10
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅵ. How to use the coagulant the and antifoaming agent
1. Coagulant (AP-20): The coagulant absorbs the remaining moisture in the
sludge, thus making the sludge easier to handle and dispose of.
To use the coagulant:
1) Turn off the filtering pump and loosen (turn counterclockwise) the
locking mechanism of the lid of the filtering equipment.
2) Remove the locking ring. See Chapter 2 for locking ring details.
3) Remove the filter from the filtering equipment and move it to a
prepared container.
4) Put 2~3 spoons of the coagulant (AP-20) into the container. Mix the
coagulant with the sludge and wastewater thoroughly in order to speed up
coagulation.
6) Dispose of the solidified sludge in a standard plastic garbage bag.
<1> <2>

11
RDUM-100, Rev.1Rodek Co., Ltd.
<3>
<4>
<5>

12
RDUM-100, Rev.1Rodek Co., Ltd.
2. Antifoaming Agent (AF-20) The antifoaming agent inhibits the formation of
bubbles and deodorizes the wastewater. The antifoaming agent, in addition
to using the Air deodorization equipment (RDS-20), enhances the
deodorization effectiveness of the lens dust filtering system.
- Before or during lens processing, put 2 cups of AF-20 into the Lens edger
and wastewater tank to reduce bubble generation.
<1> <2> <3>

13
RDUM-100, Rev.1Rodek Co., Ltd.
before using the antifoaming agent after using the antifoaming agent
▶If you use AF-20 : The sludge will settle at the bottom of the
wastewater tank and will be transferred to the filtering equipment by the
filtering pump.
If you don’t use AF-20, the microplastics will stick to the bubbles in
the wastewater and will not settle at the bottom of the wastewater tank.
※To reduce wastewater odor, put 2 cups of the antifoaming agent into the
wastewater tank.

14
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅶ. Parts
The following parts are included during purchase of the Lens Dust Filtering
System:
1) Activated carbon cartridge 1ea
2) A.V filter 5ea
3) HEPA filter 1ea
4) Filter 5ea
5) Fuse (3A) 4ea
6) Power cord (earthing terminal included) 2ea
7) User manual 1ea

15
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅷ. Consumables
Part Name Part No. Picture
Antifoaming agent AF-20
Coagulant AP-20
Filter RFS-20F
A.V filter RDS-20AF
HEPA filter RDS-20HF
Activated carbon
cartridge
RDS-20CT

16
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅸ. Specifications
1. Filtration method: Circulation & Pressure type
2. Deodorization method : Carbon filter type (carbon filter is
separately sold)
3. Korean Design Patent Application Number : ①30-2020-0012868
②30-2020-0012869
4. Korean Patent Application Number : ①10-2020-0039648
5. External Dimensions : ①668(L) x 504(W) x 540(H) (RFS-20)
②225(L) x 270(W) x 490(H) (RDS-20)
6. Weight : RFS-20: 34kg ± 5kg; RDS-20: 13kg ± 2kg
7. Rated voltage : AC 220V, 60Hz
8. Power consumption : 260 VA

17
RDUM-100, Rev.1Rodek Co., Ltd.
Ⅹ. Precautions
Please check one more time before using this
product.
To maintain the performance of this product, please take note of the
following.
PrecautionsIf you fail to follow the precautions:
Be sure to install the A.V filter and
HEPA filter.
Without the A.V. and HEPA filters, the RDS-20
cannot remove odors, and the lifespan of the
activated carbon could be substantially shortened.
R
eplace the Activated carbon
cartridge annually or after edging
approximately 10,000 lenses.
If the Activated carbon is blocked, the
deodorization performance could be substantially
reduced.
The activated carbon cartridge replacement time
could vary depending on the type of lens
processed.
Be sure to connect the air
deodorization equipment hose
properly.
If there is
a breach in the connection between the
wastewater tank and the air deodorization
equipment, odor may leak out of the system.

18
RDUM-100, Rev.1Rodek Co., Ltd.
Don’t damage the deodorization
hose.
A damaged hose will cause odor leaks.
Use only the antifoaming agent
supplied by Rodek.
If you use anything other than the specified anti
foaming agent, excessive bubbles may form which
may cause device problems.
Please do not put coagulant into
this dust filtering system.
If coagulant is put into the system
, it may cause
pump or filter failure.
Please maintain the temperature
around this product over 0℃.
If the temperature around the product in winter is
below 0℃, the water in the product may freeze and
it may cause device failure.
Please check the water level in the
wastewater tank.
If the water level in the wastewater
tank is too
high, bubbles can be circulated in the system in
large quantities, blocking the wastewater f
ilter and
activated carbon air filter.
If the water level of the wastewater tank is too low,
the wastewater temperature can rise, causing water
vapor generation and blockage in the wastewater
filter and activated carbon air filter.

19
RDUM-100, Rev.1Rodek Co., Ltd.
About This Document
Document No.: RDUM-100
Printed in the Republic of Korea
Revision Printing Date
00 September 2020
Copyright
Copyright © 2020 Rodek Co., Ltd.
EU Directives
The Lens Dust Filtering System (RFS-20, RDS-20) complies with the requirements of the
following directives and carries the CE Mark accordingly:
EMC Directive 2014/30/EU
LVD Directive 2014/35/EU
RoHS Directive 2011/65/EU
Manufacturer
Rodek Co., Ltd.
61 Jikjidae-ro 456 beongil, Heungdeok-gu, Cheongju-si, Chungcheongbuk-do, Korea.
Tel: +82-43-274-2520 Fax: +82-43-275-2520
Email: overseas@rodek.co.kr
Website: http://www.rodek.co.kr
EU Authorized Representative
OBELIS S.A
Boulevard Brand Whitlock 30,
1200 Brussels,
Belgium
This manual suits for next models
1
Table of contents
Popular Water Filtration System manuals by other brands

Essilor
Essilor Neptune user manual

Osmio
Osmio EZFITPRO Series installation guide

Aquamira
Aquamira CHEMICAL IV Series user manual

Hayward Pool
Hayward Pool IS144T instruction manual

Pentair
Pentair INTELLICHLOR COMSYS-6 installation guide

Hydac
Hydac FAM 5 FluidAqua Mobil Operating and maintenance instructions