
Contents NRT
1081.0483.12 4 E-9
2.1.6 Enhanced Measurement Accuracy ...............................................................................2.5
2.1.6.1 Using Frequency Response Correction............................................................2.5
2.1.6.2 Zeroing .............................................................................................................2.7
2.1.6.3 Increasing the Measurement Accuracy for Modulated Signals ........................2.7
2.1.6.4 Selecting Forward Power (FWD) or Absorbed Power (F-R) ............................2.8
2.1.6.5 Reference Plane and Cable Losses.................................................................2.8
2.1.7 Measurement with Several Sensors..............................................................................2.9
2.2 Basic Operating Functions................................................................................................. 2.10
2.2.1 Front-Panel Keys.........................................................................................................2.10
2.2.2 Operation via Function Keys .......................................................................................2.11
2.2.3 Scaling of Bargraphs and Underrange Identification...................................................2.12
2.2.4 Selection of the Active Sensor ....................................................................................2.12
2.2.5 Menu Operation...........................................................................................................2.13
2.2.5.1 Types of Menu Parameters............................................................................2.13
2.2.5.2 Numeric Entries..............................................................................................2.14
2.2.5.3 Menus and Notation .......................................................................................2.15
2.3 CONFig Menu.......................................................................................................................2.16
2.3.1 ENV KEY (Selection of Envelope Parameters)...........................................................2.17
2.3.1.1 Measurement of Peak Envelope Power.........................................................2.18
2.3.1.2 Crest Factor....................................................................................................2.19
2.3.1.3 Average Burst Power......................................................................................2.20
2.3.1.4 Cumulative Distribution Function....................................................................2.22
2.3.2 POWER (Configuration of Power Display)..................................................................2.23
2.3.3 MAXHOLD (min/max display on/off) ...........................................................................2.23
2.3.4 MAXDISP (display of max value, min value or difference)..........................................2.24
2.3.5 SCALE (Setting of Scale Limits for Bargraphs)........................................................... 2.24
2.3.6 RESOL (Resolution of Indication in Display)...............................................................2.25
2.3.7 INT.TIME (Setting the Integration Time) .....................................................................2.26
2.3.7.1 USER (Entry of a User-Defined Integration Time) .........................................2.26
2.3.8 SPEC (Special Functions)........................................................................................... 2.27
2.3.8.1 ∆REF (Reference Value for Relative Power Measurements)........................ 2.27
2.3.8.2 SWR.ALARM (SWR Monitoring).................................................................... 2.27
2.3.9 ∆KEY (Configuration of Relative Units)......................................................................2.28
2.3.10RFL KEY (Configuration of Reflection Indication) ....................................................... 2.29
2.4 CORRection Menu...............................................................................................................2.30
2.4.1 FREQ (Frequency Response Correction )..................................................................2.31
2.4.1.1 Entry of Carrier Frequency for NRT Sensors .................................................2.31
2.4.1.2 Entry of Carrier Frequency for NAP Sensors .................................................2.32
2.4.2 ZERO (Zeroing)...........................................................................................................2.32
2.4.3 MODULATION (correction of measured values with modulated signals).................. 2.33
2.4.4 MEAS.POS (Definition of Reference Plane) ...............................................................2.34