1. INSTALLING RECEIVER BOX
(SAFETY EDGE)
1 Remove all 4 screws from cover (fig.1) to reveal
control board inside (fig.2).
2 Place the Receiver box on the wall with the
cable pointing downwards at a comfortable
height to operate the push buttons, but out of
the easy reach of children. Between 1500mm up
from the floor and 300mm down from the roof/
ceiling is recommended, mark the 4 fixings, drill
and secure the unit to the wall.
3 If you have a safety brake with a cable then run
the two core cable from the safety brake end
across to the same end as the receiver box,
making sure to securely fix the cable out of the
way of the working mechanism.
4 The Glands at the bottom are for the cables to
be inserted, (1) motor wire (2) power wire (3)
safety brake if supplied.
5 Wiring as follows (fig.3, 4 & 5):
Terminal 1 – Earth Motor Wire
Terminal 2 – Earth Power Wire
Terminal 3 – Power Brown Live Wire
Terminal 4 – Power Blue Neutral Wire
Terminal 5 – Motor Open Wire (left hand
motor Black / right hand motor Brown)
Terminal 6 – Motor Blue Neutral Wire
Terminal 7 – Motor Close wire (left hand
motor Brown / right hand motor Black)
Terminal 16 – Safety Edge Brown Wire
Terminal 17 – Safety Edge Green Wire
Terminal 18 – Safety Edge White Wire
Safety Brake (fig.5 & 6):
Terminal 21 - Safety Brake = Blue Safety
Brake Wire / No safety Brake = Link cable to
Terminal 22.
Terminal 22 - Safety Brake = Brown Safety
Brake Wire / No Safety Brake = Link wire to
Terminal 21. fig.2
fig.1

3
Rollerdor RD10X2ELL Control Box, Edition 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
fig.4 Le Hand Motor
fig.5 Safety Brake fig.6 No Safety Brake
2. ELECTRICAL CONNECTIONS
fig.3 Right Hand Motor

4
Rollerdor RD10X2ELL Control Box, Edition 2022/1
3. SETTING UP WIRELESS
SAFETY EDGE KIT
(OPTICAL EDGE)
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
CHECKING BASE RAIL UNIT
CHECKING CONTROL BOX
LIMITS
1 Your base rail unit is already installed on the last slat of your
curtain the same side as the power. it is a small black unit,
undo all 3 screws and remove the lid (fig.7).
2 Check GREEN LED is on, wires are secure and are wired
follows: Both banks of terminals from outside to in are
Brown - White - Green (fig.8).
1 Control box Dip Switches: check dip switches on main board
(fig.9) dip switch number 1 should be on and number 2 off.
The control box is supplied in Hold to Run operation for open and
close, if the limits of the motor have not been set then please set
them now using the P1 (UP) & P2 (Down) buttons (fig.9), if when
you press and hold either of the buttons the unit just beeps then
you will need to put the unit into Hold to Run by pressing and hold-
ing both P1 & P2 buttons at the same time until you hear a single
beep (fig.10). Once you have finished setting limits once again
press and hold both P1 & P2 buttons at the same time until you hear
a single beep to return to single press operation.
fig.7
fig.8
fig.9fig.10
Dip switches
P2
P1

5
Rollerdor RD10X2ELL Control Box, Edition 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
PROGRAMMING TRANSMITTER’S
Programming Transmitters 2 Channel:
1 Press P1 (PROG) button two times, on last press HOLD causing the buzzer to emit a continuous sound.
2 Whilst P1 (PROG) is still pressed, press the top button on the transmitter, you will hear a faster beeping sound.
Deleting ALL transmitters:
1 Press P2 (DEL) 5 times and on last press HOLD for at least 10 seconds, buzzer emits a rapid beeping sound.
2 Once the sound becomes continuous release the P2 button.
P2
P1

6
Rollerdor RD10X2ELL Control Box, Edition 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
WIRELESS KEY PAD
1 Undo and remove the small screw at the bottom and lift off
the front cover.
2 Using the back-plate as a template, mark the positions
of two suitable fixing holes onto the wall then secure the
back-plate to the wall using the plugs and fixing screws
provided.
3 Install the 9v alkaline battery that has been supplied then once
set up and programming is completed push the keypad onto
the back-plate and secure in place with the screw.
INSTALLATION
1 The keypad is supplied with a factory access code number
"12345".
2 To pair keypad to receiver box, enter the Access code
“12345”, within 5 seconds press and release PROG (P1)
button, then press and hold PROG (P1) button. You will hear
a continuous beep from the control box, whilst holding
the button press and hold Number 1 on the keypad, the
continuous beep will change to faster beep on hearing this
release all buttons and the keypad is now programmed.
PAIRING USING ACCESS CODE
For security reasons it is essential that the access code num-
ber is changed to another 5 digit number these numbers can
be in any combination of numbers 0-9, excluding A and B.
To change access code follow this sequence: Enter access code
“12345”, press M1 button (white button on the back of the
keypad) a beep will be emitted, enter your new 5 digit code,
within 1 second enter this same code again, when you hear a
continuous beep for approx. 2 seconds this confirms the code
has been changed.
CHANGING ACCESS CODE
Enter your individual 5 digit code each number will emit
a short beep to signify it has been registered and the final
number will give a longer beep to say full code has been
entered, Press either number 1 to open or number 3 to close.
OPERATION

7
Rollerdor RD10X2ELL Control Box, Edition 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
1 The curtain is supplied with stops at each end to stop an uneven floor having an eect (fig.13) but if the curtain
reopens having hit the floor the safety edge exclusion should be set to ‘turn o’ the edge 50mm before it hits the floor.
Please be aware the safety edge will have to return to the top limit before closing and the alarm will be disabled.
SAFETY EDGE EXCLUSION ZONE
fig.13

8
Rollerdor RD10X2ELL Control Box, Edition 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
4. TROUBLESHOOTING

Rollerdor RD10X2ELL Control Box, Edition 2022/1
Rollerdor Ltd
10 & 12 Jarrold Way
Bowthorpe Employment Area
Norwich
Norfolk NR5 9JD
+44 (0)1603 743215
sales@rollerdor.net
www.rollerdor.net
Company Registration Number. 10676267
Registered Oice Address:
Rollerdor Ltd, Bankside 300 Peachman Way,
Broadland Business Park, Norwich,
Norfolk, United Kingdom, NR7 0LB
Edition 2022/1
Table of contents
Other Rollerdor Controllers manuals
Popular Controllers manuals by other brands

KE2
KE2 Evaporator Efficiency Condensed Quick Start Guide

Brink
Brink Air for life Installation regulations

SMC Networks
SMC Networks LEFS 16 Installation and maintenance manual

YASKAWA
YASKAWA PROFINET V1000 installation manual

Fortinet
Fortinet FortiADC 1000F quick start guide

Hach
Hach SC4500 User instructions