5) "-" key means humidity down, press "-" key each time, the set humidity decrease for 1%. Press"-
"key continuously, the set humidity decrease by 5% per second. When you set the humidity, the
humidity display on LCD light flash, it will show the current humidity if without operation in 5
seconds, the humidity display on LCD light on.
6) Accumulative work time key: press the accumulative work time key, time display light flash, the
unit come into current time setting.
Press "+" or "-" key to set current time, press "+"or "-" key each time, time increase or decrease for
one minute. Press "+"or "-" key continuously, time increase or decrease for ten minutes. The time
display shows current time if no operation after 5 seconds, time display light on. Press "Accumulative
work time key" for 3 seconds, the current time on LCD turn to accumulative work time, and then turn
back to current time after 30 seconds.
3 Instruction of function mode
Unit makes a sound "di" when power on, switch button on humidity mode. The indicator light of
"Dehumidify icon" on. Default setting is humidity 30%, machine's dehumidifying range is 30%-90%,
use "+" and "-" key on panel to adjust humidity setting. If keep pressing"-"key when setting humidity
is 30%, unit come into continuous dehumidify mode, humidity display on LCD is "CO". The humidity%
flash when setting humidity, then display room air humidity after 5 seconds. When the room
temperature is low, unit run into Auto-Defrost function. Compressor works, motor doesn't when
defrosting, "Defrost icon "light on, "Fan icon "light off. Display go back ex-setting which before
defrosting.
"Water full icon" light on when the water tank is full, machine stop work after 45 seconds, buzzer
makes sound like "di" for 5 times, E4 display on LCD. Buzzer will continue alarm, make sound "di" 3
times for each 5 minutes till user empty the water tank. (unit with tank only)
Pump works when water tank is full to take out the water. (unit with pump only)
"Accumulative work time" on display means how much time unit have be operated.(This number is
calculated by hour, the first ten minutes after latest power off doesn't calculate in)
Four. Notice of operation
1. There have 3 minutes protection wait when unit re-start after compressor stop work.
2. The operated temperature is 5 ~32°C
3. When displace the unit, do not slope over 45°.
4. Compressor works and fan motor doesn't work when unit is defrosting.
5. We suggest wash the filter once per month. Immerge filter in warm water when cleaning,
lightly brush, install in after airing.
6. Make machine's air inlet and outlet 10cm away from wall, avoid to bad dehumidify effect.
7. Clean up the water tank after using, avoid skeeter growth.
8. Pull out plug if won't use unit for long time. Coil the power wire on coil seat, and insert plug
into plug fixation.