Romus FM 1800 User manual

Mode d’emploi
Universal mixer« FM 1800 »
Ref. 94002
INSTRUCTIONS FOR USE_GB
This manual refers to the mixer above. It contains important advice on
operating and handling. Take this into account when offering the product to
third parties. Keep these instructions for future reference !

Mode d’emploi
Universal mixer« FM 1800 »
Ref. 94002
INTRODUCTION
Warning! Read before commissioning
Before the first commissioning. Read carefully and completely this manual. Non-compliance with safety instructions
and handling can cause serious bodily injury. Before each use, check the unit is in good condition. Do not put the unit
into operation until you are familiar with all the functions. Make sure you can stop as quickly as possible in an
emergency unit. An instruction manual is an integral part of the unit. Keep carefully all documents and put them to
use by a third party.
Intended use
This tool is for mixing different liquids.
Any other use or improper modification of the device can lead to serious dangers.
The manufacturer declines any liability for damage resulting from improper use.
This device is not designed for commercial use
Controls
1. Power ON / OFF
2. Lock button
3. Speed selector
4. Variable speed drive
5. Key
6. Agitator
The accessories shown or described are not
not all included in the supply.
Power
No-load speed
(1 speed)
No-load speed
(2 speed)
Ø Agitator
weight
Protection
level
1800 W
150-300 min-1
300-650 min-1
140 mm et 160 mm
6.0 kg
II
specifications:
①
④③
①②

Mode d’emploi
Universal mixer« FM 1800 »
Ref. 94002
SECURITY
Safety instructions
•To work safely with this tool, it is essential to read this manual carefully and
•maintenance and adhere strictly to instructions exempted.
•Also observe the safety precautions inherent in the use of power tools.
•Check the cable and plug before each commissioning. Repair defects by a technician.
•This tool should not be used to work in damp areas, in rain, fog or snow, or in an explosive atmosphere.
•Check if the power is off before connecting to the network. Check if necessary the position of the
corresponding switch.
•Careful with long hair and jewelery. Work with adequate holding blanket, tight and buttoned.
•Always disengage the cable to the rear of the tool. Do not pull excessively on the cable, or put or pull on sharp
edges.
•Always a firm footing and balance.
•Use the additional handle.
•Prepare to compensate for the torque at startup.
•Secure the container containing the substances mixed with the soil so that it can not move.
USE
Commissioning and Application
Improper application may damage the tool.
So please follow the instructions below:
Use only tools to the specified diameter.
Do not change the way tool as the regime falls sharply or the engine stops.
Check that the information on the rating plate correspond to the actual voltage. The tools suitable for 230 V can also
operate on 220 V / 240 V.
Tighten the agitator
Screw the tool tip M 14 as possible in the chuck and tighten with the key 22 supplied as accessories.

Mode d’emploi
Universal mixer« FM 1800 »
Ref. 94002
Starting and stopping
To turn the tool on, press the switch and hold. The tool turns off when you
release the switch.
Continuous operation
Continuous operation works: push the switch and at the same time on the lock
button. The switch is blocked and continuous operation enabled.
permanent stop operation: press the switch again and release. The switch lock is
released and the permanent operation stopped.
Disassembly of the tool (agitator)
Place the wrench 22 of the hex nut from the end of the tool (agitator) and
unscrew it from the tool holder by turning left.
Engine electronics / control engine electronics
Limiting the starting current
Soft start and electronic control ensures a smooth start. This also has the advantage to prevent any projection of the
liquid at start-up of the tool. With low startup current, a 16 A fuse sufficient to protect the tool.
Reduced idling speed
Electronics reduces the tool speed when the idling. This reduces noise
levels and engine wear and gear
Speed pre-selection
The speed selector to preset the system gradually. The required speed depends on
the type of mixed liquid, it is recommended to perform a practical test.
Speed selector
The speed selector allows you to select two speed ranges:
Speed 1 min = 150 min-1 to 300min-1
Speed 2= 300 min-1 to 650 min-1
It is possible to switch the speed when the tool is running.
It should not do so under full load.
Electronic controller
The electronic controller maintains almost constant speed under load and empty. This ensures a steady mixture of
liquids.

Mode d’emploi
Universal mixer« FM 1800 »
Ref. 94002
Electronic protection against overloads
In case of extreme overload of the tool, an electronic overload protection protects the motor against damage. In such
cases, the engine stops and will not restart until the load is reduced.
Thermal protection against overload
To protect the tool against overheating in case of high continuous load, safety electronics shut down the engine if the
temperature exceeds the critical threshold. After cooling for about 3 to 5 minutes, the tool is ready for use under full
load. If the tool is hot, the thermal protection against overloads reacts earlier.
STORAGE
Only store the tool in a dry and frost. Make sure the tool is stored out of reach of children.
MAINTENANCE AND CLEANING
•Unplug from the power socket before performing any cleaning tasks.
•Avoid inhalation of liquid in the housing of the tool. Use a soft cloth to wipe the housing. Never use gasoline, solvents
or detergent attacking the plastic.
•It is highly recommended to clean the agitators directly after completing the work.
•Regularly clean the ventilation slots of the housing.
•If the carbon brushes are worn, the tool automatically switches off. It should then send the tool to maintain the S.A.V.
•After about 100 hours of work, check the coals and, if necessary replace and clean the crankcase.
•After about 200 hours of work, repeat the lubrication of the crankcase.
•WARNING ! To maintain the insulation, the tool should then be subject to safety inspections. For this reason,
this work should only be performed in an authorized service workshop.
ELIMINATION
Disposing
Perform the disposal of the device, accessories and packaging in accordance with the regulations on environmental
protection. Plastic parts are marked to allow for safe disposal.
DECLARATION OF CONFORMITY
The geo-FENNEL company, DE-Baunatal, hereby declares that the unit designated below. Because of its design
and production, as well as distributed executions, complies with safety specifications and health of the applicable
EC directives. Any changes to the device without our consent voids this declaration.
Applicable EC directives
Machinery Directive: 2006/42 / EC
EC Low Voltage Directive: 2006/95 / EC
EC Electromagnetic Compatibility Directive: 2004/108 / EC
Applied harmonized standards
EN 60745-1 / A11: 2010; EN 60745-2-1: 2010
EN 55014-1 / A1: 2009; EN 55014-2 / A2: 2008
EN 61000-3-2 / A2: 2009; EN 61000-3-3: 2008