Rosslare MD-CC101 User manual

MD-CC101
Installation Instructions GSM Communication Stick
1
0706-0960371+00
1. Introduction
Th e M D -CC101, " GSM Stick"isa dedicated GSM module
designed to fit snugly in the HomeLogiX
TM
Th e M D -CC101 usesGSM communicationsto back up the
telephone line (PSTN) in case of telephone line failure, or else
it acts asthe primary reporting mean.
alarm panel series.
When using the MD-CC101 GSM module the system also
allowsprivate phone to receive both voice and SM S
messages(alerts, troubles, bypass, arm/disarm), the user can
also se n d commandsto the system via SM S m e ssa g e s,
allowing arming (home/away), disarming , PG M activatio n /
deactivation.
• Fu l l e v e n t re p o r t i n g
• Contact ID reporting protocol
• 2-way voice communication
• GSM communication - via GSM Quad Band 900 / 1800
MHzor 850 / 1900 MHzmodem
• Th r e e o p e r a t i n g m o d e s - backup for the controldialer,
primary alarm communicatorand parallel reporting
channel
• Priv a t e vo ic e / SM S re p o rtin g
• Compatible with Rosslare’sHomeLogiX
TM
• Pa n e l re m o te up lo a d in g / d o w nlo a d in g sup p o rt v ia G SM
wireless
control panels
• Quad freq uenc ies b and s for worldwide coverage
• Re m o t e ly u p g ra d e f irm w a re
2. Technical Specifications
2.1 ELECTRICAL SPECIFICATIONS
Input Voltage 3.4V – 4.5V (fro m c o ntrol p a nel)
Current consumption
Tr a n sm i t : 2 m A
St a n d b y : 1 . 2 A
Ex t e rn a l A n t e n n a 50 O hm a nte nna
Modem type GSM Quad band
Fre quency range GSM 850, EGSM 900, DSC 1800,
PC S 1900 ( M Hz)
GSM Class Sm a l l M S
SI M c a rd su p p o rt 1.8V , 3V
Se ria l p o rt
115200 b p s
2.2 ENVIRONMENTAL SPECIFICATIONS
Operating environment Ind o o r u se
Operating temperature -30°C to 80°C (-22°F to 176°F)
Sto ra ge Te m p e ra t u r e -45°C to 90°C (-49°F to 194°F)
Operating humidity
0% to 85% (Non-Condensing)
2.3 PHYSICAL SPECIFICATIONS
Dimensions 16.2 x 7 cm (6.38 x 2.75 inc h)
We ig ht
68 g (2.4 oz.)
3. Installation
3.1 General
Th e M D -CC101 isintended for use with the HLX-40 fa m ily thus
enhancing the system’sperformance by allowing GSM
communication used asa backup line communication,
when a problem occurwith the PSTN line.
Th e MD-CC101 GSM St i c k module also allowsprivate phone
to rec eive both voice and SM S m e ssa g e s (alerts, troubles,
bypass, arm/disarm) from the HLX-40 system , the user can
also se n d commandsto the system via SM S m e ssa g e s,
allowing arming (home/away), disarming , PG M activatio n /
deactivation.
3.2 Installing the MD-CC101 GSM Stick
1. Insert the GSM stick into the connector slotslocated on
the back of the HLX-40 se e the insta lla tio n fig ure.
2. Ti g h t e n t h e p l a c e m e n t sc r e w s o n b o t h si d e s o f t h e G SM
St i c k t o se c u r e o n t o t h e p a n e l .
Note:
.
Wh e n using th e HL-X40 w it h t h e M D -CC101 unit
attached, make sure to place the unit in a location
with strong GSM reception.
3. Open the SIM holder by sliding it sideways. Insert the SIM
card into the holderand close the holder.
Note: En su re t h a t t h e sy st e m i s p o w e re d o f f b e f o re
attempting to install the MD-CC101 and inserting the
SI M c a r d .

2
0706-0960371+00
3.3 Activating the DC-101 GSM Stick
Th e H L X -40 syste m a uto m a tic a lly d e te c ts the a va ila b ility o f
the MD-CC101 GSM stick upon initial power up of the system,
the HLX-40 will a lso te st the rec ep tio n levels and d isp lay them
on the screen, the reception must be above 21.00 for be
re a d y u se .
After installation of the MD-CC101 GSM Stick, relevant menus
and optionswill be available in the HLX-40 me nu syste m .
Th e G SM St i c k e n h a n c e m e n t o n l y w o r k s i n c onjunction with a
battery pack.
4. Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) ONE YEAR LIMITED
WARRANTY is applicable worldwide. This warranty supersedes any other
warranty. Rosslare's ONE YEAR LIMITED WARRANTY is subject to the
following conditions:
Warranty of Rosslare's products extends to the original purchaser (Customer)
of the Rosslare product and is not transferable.
Warranty
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE)
warrants that the MD-CC101 GSM Stick, to be free from defects in materials
and assembly in the course of normal use and service. The warranty period
commences with the date of shipment to the original purchaser and extends
for a period of 1 year (12 Months).
Products Covered By This Warranty and Duration
In the event of a breach of warranty, ROSSLARE will credit Customer with the
price of the Product paid by Customer, provided that the warranty claim is
delivered to ROSSLARE by the Customer during the warranty period in
accordance with the terms of this warranty. Unless otherwise requested by
ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative,
return of the failed product(s) is not immediately required.
Warranty Remedy Coverage
If ROSSLARE has not contacted the Customer within a sixty (60) day holding
period following the delivery of the warranty claim, Customer will not be
required to return the failed product(s). All returned Product(s), as may be
requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole
discretion, shall become the property of ROSSLARE ENTERPRISES LTD.
AND /OR SUBSIDIARIES.
To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to
obtain an RMA number after which, the product must be returned to the
Manufacturer freight prepaid and insured
In the event ROSSLARE chooses to perform a product evaluation within the
sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or
equivalent charge will be applied to each Product for labor required in the
evaluation.
Rosslare will repair or replace, at its discretion, any product that under normal
conditions of use and service proves to be defective in material or
workmanship. No charge will be applied for labor or parts with respect to
defects covered by this warranty, provided that the work is done by Rosslare
or a Rosslare authorized service center.
ROSSLARE shall not be responsible or liable for any damage or loss resulting
from the operation or performance of any Product or any systems in which a
Product is incorporated. This warranty shall not extend to any ancillary
equipment not furnished by ROSSLARE, which is attached to or used in
conjunction with a Product, nor to any Product that is used with any ancillary
equipment, which is not furnished by ROSSLARE.
Exclusions and Limitations
This warranty does not cover expenses incurred in the transportation, freight
cost to the repair center, removal or reinstallation of the product, whether or
not proven defective.
Specifically excluded from this warranty are any failures resulting from
Customer's improper testing, operation, installation, or damage resulting from
use of the Product in other than its normal and customary manner, or any
maintenance, modification, alteration, or adjustment or any type of abuse,
neglect, accident, misuse, improper operation, normal wear, defects or
damage due to lightning or other electrical discharge. This warranty does not
cover repair or replacement where normal use has exhausted the life of a part
or instrument, or any modification or abuse of, or tampering with, the Product if
Product disassembled or repaired in such a manner as to adversely affect
performance or prevent adequate inspection and testing to verify any warranty
claim.
ROSSLARE does not warrant the installation, maintenance, or service of the
Product. Service life of the product is dependent upon the care it receives and
the conditions under which it has to operate.
In no event shall Rosslare be liable for incidental or consequential damages.
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE
ENTERPRISES LTD.AND IT’S SUBSIDIARIES’S WARRANTY
Limited Warranty Terms
70BTHE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON,
WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF
ROSSLARE.
71BTHIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER
WARRANTIES.ALL OTHER WARRANTIES EXPRESSED OR IMPLIED,
INCLUDING WITHOUT LIMITATION,IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,ARE
SPECIFICALLY EXCLUDED.
72BIN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF
THE PURCHASE PRICE OF THE PRODUCT,OR FOR ANY OTHER INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES,INCLUDING BUT NOT LIMITED TO
LOSS OF USE,LOSS OF TIME,COMMERCIAL LOSS,INCONVENIENCE,AND
LOSS OF PROFITS,ARISING OUT OF THE INSTALLATION,USE,OR INABILITY
TO USE SUCH PRODUCT,TO THE FULLEST EXTENT THAT ANY SUCH LOSS
OR DAMAGE MAY BE DISCLAIMED BY LAW.
73BTHIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A
VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY.
5. 30BContact information
37BAsia Pacific, Middle East
42BHe a d q u a rt e rs:
18B905-912 Wing Fa t Ind ustria l Bld g , 12 Wa ng Ta i Ro a d ,
Ko w lo o n Ba y Ho n g Ko n g
19BTe l : + 8 5 2 2 7 9 5 -5630 Fa x: +852 2795-1508 E-mail:
su p p o rt . a p a c @ro ssla re se c u rit y.c o m
38BUnited States and Canada
20B1600 Hart Court, Suite 103 Southlake, TX, USA 76092
21BToll Free :+1-866-632-1101 Lo c a l:+1-817-305-0006 Fa x: +1-
817-305-0069 E-mail: support.na@rosslaresecurity.com
39BEurope, Africa
43BGlobal Technical Support & Training Center:
22BHa M e le c ha 22 Ro sh Ha A y in , Isra e l 4 8 091
23BTe l : +972 3 938-6838 Fa x: +972 3 938-6830 E-mail:
su p p o rt . e u @ro ssla re se c u ri t y .c o m
40BSouth America
24BPrin g le s 868, 1640 M a rt in e z Bu e n o s A ire s Argentina Te l :
+54 11 4798-0095 Fa x : +54 11 4798-2228
41BWeb Site: www.rosslaresecurity.com
Other Rosslare Other manuals
Popular Other manuals by other brands

Dennerle
Dennerle Reusable 300 Space operating instructions

Sunion
Sunion MD-150M user manual

Bio-Therapeutic
Bio-Therapeutic bt-zoom quick start guide

IBM
IBM HS21 BLADECENTER - X5460 FOR SPEC CPU2006 specification

NextWave Digital
NextWave Digital TDR-2190 operating instructions

Thetford
Thetford Cassette C-402C Instructions for use