V715+ OPERATING INSTRUCTIONS
Make sure that the delivered unit conforms to your requirement, and also check for any missing or damaged parts.
Before using this V715+, be sure to read this OPERATING INSTRUCTIONS thoroughly to ensure proper operation.
[Accessories] V715+ OPERATING INSTRUCTIONS: 1 copy, Fixtures: 6 pcs, Clamp for USB cable: 1 pce
[Models]
Notes on Safe Usage
In this "V715+ OPERATING INSTRUCTIONS", you will find various notes categorized under the following two levels with
the signal words "Danger" and "Caution."
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious
injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury and could cause property damage.
Even some items indicated may also result in a serious accident.
Never use the output function of AnyTouch for operations that may threaten human life or to damage the system,
such as switches to be used in case of emergency. Please design the system so that it can cope with malfunction
of a touch switch. A malfunction of the touch switch will result in machine accident or damage.
Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection.
Otherwise, electrical shock or damage may occur.
Never touch any terminals while the power is on. Otherwise, electric shock may occur.
You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without the
terminal cover in place, an electric shock may occur.
The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, never swallow the
leaked liquid crystal. If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly.
Never disassemble, recharge, deform by pressure, short-circuit, nor reverse the polarity of the battery, and never
dispose of the battery in fire. Failure to follow these conditions will lead to explosion or ignition.
Never use a battery that is deformed, leaks, or shows any other signs of abnormality. Failure to follow these
conditions will lead to explosion or ignition.
A power lamp blinks when a screen becomes dark, owing to the life or a malfunction of the backlight.
At this time, switches on a screen are effective. Never touch the screen when the screen becomes dark (hard to
see) and a power lamp blinks. A malfunction will result in machine accident or damage.
Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found.
Failure to do so may lead to fire, damage or malfunction.
For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile
installations, please consult your local distributor.
Operate (or store) AnyTouch under the conditions indicated in this manual and related manuals. Failure to do so
could cause fire, malfunction, physical damage or deterioration.
Understand the following environmental limits for use and storage of AnyTouch. Otherwise, fire or damage to the
unit may occur.
- Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or
cutting oil can come into contact with the unit.
- Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight.
- Avoid locations where excessive dust, salt, and metallic particles are present.
- Avoid installing the unit in a location where vibration or physical shock may be transmitted.
15 inch display
Device type
X : TFT color LCD (XGA, 32,768 colors)
Power supply type
(None) : 100-240V AC
D : 24V DC (Comply with CE/UL/cUL)

2
Equipment must be correctly mounted so that the main terminal of AnyTouch will not be touched inadvertently.
Otherwise, an accident or electric shock may occur.
Tighten the fixtures of the AnyTouch with a torque in the specified range. Excessive tightening may distort the
panel surface. Loose tightening may cause AnyTouch to come off, malfunction or be short-circuited.
Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened.
Loosened screws may result in fire or malfunction.
Tighten terminal screws on the power supply terminal block equally to a torque of 0.5 N m. Improper tightening of
screws may result in fire, malfunction, or trouble.
AnyTouch has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen may be
damaged.
Connect the cables correctly to the terminals of AnyTouch in accordance with the specified voltage and wattage.
Over-voltage, over-wattage or incorrect cable connection could cause fire, malfunction or damage to the unit.
Be sure to establish a ground of AnyTouch. Ground FG terminal which must be used for the unit. Otherwise,
electric shock or a fire may occur.
Prevent any conductive particles from entering into AnyTouch. Failure to do so may lead to fire, damage or
malfunction.
Do not attempt to repair, disassemble or modify AnyTouch at your site. RS Automation Co., Ltd. is not responsible
for any damages resulting from repair, overhaul or modification of AnyTouch that was performed by an
unauthorized person.
Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen.
Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection.
The combustible materials such as lithium or organic solvent contained in the battery may generate heat, explode,
or catch fire, resulting in personal injury or fire. Read related manuals carefully and handle the lithium battery
correctly as instructed.
Do not press two or more points on the screen at the same time. If there is a switch between the two pressed
points, it may be activated.
Take safety precautions during such operations as setting change during running, forced output, start, and stop.
Any misoperation may cause unexpected machine motions, resulting in machine accident or damage.
In facilities where a failure of AnyTouch could lead to accident threatening human life or other serious damage, be
sure that the facilities are equipped with adequate safeguards.
At the time of disposal, AnyTouch must be treated as industrial waste.
Before touching AnyTouch, discharge static electricity from your body by touching grounded metal. Excessive
static electricity may cause malfunction or trouble.
A LED lamp illuminates (red) during access to the CF card. Do not insert or remove the CF card or turn the power
off on illuminating the LED lamp. Doing so may destroy data on the CF card. Before mounting or removing the CF
card or turn the power off, be sure to check that the light of the LED lamp is turned out.
UL/c-UL Approval
The V715XD+ is UL/cUL-approved. (File No. : E185413(UL60950-1), File No. : E303690(UL1604))
These products conform to the following four standards.
・UL60950-1 Information Technology Equipment - Safety - Part 1: General Requirements
・UL1604 Standard for Electrical Equipment for Use in Class I, Division 2 Hazardous Locations
・CSA-C22.2 No. 60950-1Information Technology Equipment - Safety - Part 1
・CSA-C22.2 No. 213-M1987 Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazaedous Locations
UL1604/CSA-C22.2 No. 213 Compliance and Handling Cautions
○Power, input and output wiring must be in accordance with Class I, Division 2 wiring methods - Article 501 - 10(B) of
the National Electrical Code, NFPA 70.
○WARNING: Explosion Hazard: Substitution of components may impair compliance to Class I, Division 2.
○WARNING: Explosion Hazard: Do not disconnect while circuit is alive unless area is known to be non-hazardous.
○WARNING: Explosion Hazard: When in hazardous locations, turn off power before replacing or wiring modules.
CE Marking
The V715XD+ complies with EMC directive:
EN55011 Class A, EN61000-6-2
NK Standard
V715XD+ is the product which is certified as NK Standard by NIPPON KAIJI KYOKAI.
Type Test No. : 06A014

3
English
Specifications
Item Type V715X+ V715XD+
Correspondence standard -
CE Marking:
EN61000-6-2, EN55011 Class A
UL/cUL: UL60950-1, UL1604
NK: 06A014
Power Supply
Rated Voltage 100-240V AC 24V DC
Permissible Range of Voltage 100-240V AC 10% 24V DC 10%
Permissible Momentary
Power Failure within 20ms within 1ms
Demand (maximum rating) 90VA or less 40W or less
Rushed Electric Current for 100VAC: 20A or less (10ms or less)
for 200VAC: 40A or less (10ms or less) 30A or less (1ms or less)
With-stand voltage AC external terminals to FG: 1500V AC
per minute DC external terminals to FG: 500V AC
per minute
Insulation Resistance 500V DC, 10M or more
Physical Environment
Ambient Temperature 0 to +40
Storage Ambient Temperature -10 to +50
Relative Humidity 85% RH or less (without dew condensation)
Altitude Altitude 2000m or less
Solvent Resistance No cutting oil or no organic solvent to cling to the unit
Atmosphere No corrosive gas, not so much excessive dust and no conductive dust
Mechanical
Working
Conditions
Vibration Resistance Vibration frequency: 10 to 150Hz, Acceleration: 9.8m/s2(1.0G),
Half-amplitude: 0.075mm, 3 directions of X, Y and Z: one hour
Shock Resistance Pulse shape: Sine half wave, Peak acceleration: 147m/s2(15G),
3 directions of X, Y and Z: 6 times
Electrical
Working
Conditions
Noise Resistance Noise voltage: 1500Vp-p,
Noise width: 1 s, Rise time 1ns Noise voltage: 1000Vp-p,
Noise width: 1 s, Rise time 1ns
Static Electricity Discharge
Resistance Adhere to IEC61000-4-2, Contact: 6kV, Air: 8kV
Mounting Conditions
Grounding Grounding resistance: less than 100
Structure
Protection structure: front panel complies with IP65 (when using gasket)
rear cabinet complies with IP20
Form: in a body
Mounting procedure: inserted in a mounting panel
Cooling System Cooling naturally
Weight (kg) approx. 5.2 approx. 5.0
Dimensions W X H X D (mm) 382.8 ×312.8 ×81.1
Panel Cut-out (mm) 369.4 +0.5
-0 X 299.4 +0.5
-0
Material Aluminum

4
Names of Components and Dimensions
Dimensions (unit : mm)
1. Display 9. CF card interface (CF)
2. Power lamp (POWER) * 10. Power supply terminal block
3. Function switches 11. LAN connector (LAN)
4. Option IF unit connector (CN5) 12. PLC communication connector (CN1)
5. Extension memory connector (MEMORY) 13. Modular jack connector (MJ1,MJ2)
6. Option unit connector (CN7) 14. USB-B (slave port)
7. Battery holder 15. USB-A (master port)
8. DIP switch 16. Mounting holes
* Power lamp illuminates (green) when the power is supplied. The lamp blinks when a backlight is unusual.
1
23
9
F1 F2 F3 F4 F5 F6 F7
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
15141310 11 12
16
45 6
7
8
312.8
382.8
298.4
368.4
81.1 8.3
47.8
43.4
Serial Connector (CN1)
CN1 is used for communicating between a PLC and a V715+ (RS-232C、RS-422/485).
The pin arrangement of serial connector is as follows:
CN1(Dsub 25pin Female)Pin No. Signal Contents
1
14
13
25
1 FG Frame ground
2 SD RS-232C send data
3 RD RS-232C receive data
4 RS RS-232C RS request to send
5 CS RS-232C CS clear to send
6 Not used
7 SG Signal ground
8 Not used
9 +5V Use prohibited
10 0V Use prohibited
11 Not used
12 +SD RS-422 send data (+)
13 -SD RS-422 send data (-)
14 +RS RS-422 RS send data (+)
15 Not used
16 Not used
17 -RS RS-422 RS send data (-)
18 -CS RS-422 CS receive data (-)
19 +CS RS-422 CS receive data (+)
20 Not used
21 -Use prohibited
22 -Use prohibited
23 Not used
24 +RD RS-422 receive data (+)
25 -RD RS-422 receive data (-)

5
English
MJ1, 2, and LAN port are modular jack 8pins. Check the name of the port to insert a cable to the
appropriate port. When using a LAN cable: For safety, do not connect for device that might have
excessive voltage to the network port.
USB Port (USB ver.1.1)
Type A (master port): For USB printer and CF card reader/writer
Type B (slave port): For computer connection (screen data transfer)
* Refer to "V715+ Hardware Specifications" for the usage of the clamp for USB cables.
Mounting Procedure
1. Insert the unit into the mounting panel (max. thick: 5 mm).
2. Insert six fixtures attached to the V715+ into the
mounting holes, and tighten them with the locking
screws. (Torque: 0.7 to 1.0N m)
* To prevent static electricity, be sure to connect the mounting panel to the ground.
3. Mount the gasket so that it will be sandwiched securely
between the unit and the mounting panel.
Mounting Angle
The unit shall be installed within the angle of 0 to 135 degrees.
CN5
CN7
MEMORY
MJ2 U-B
CF
MJ1 U-A
CN1
LAN
Modular Jack (MJ1/MJ2)
This port is used for such connection as data transfer, temperature controller network, bar code reader, CREC, and V-I/O,
etc. The pin arrangement of modular jack is as follows:
MJ1/MJ2 Pin No. Signal Contents
12345678
1 +SD/RD RS-485 data (+)
2 -SD/RD RS-485 data (-)
3 +5V Output power supply +5V *
* The maximum current for the output power supply (+5 V) is 500 mA which is
total usage of MJ1, MJ2, or USB-A. When "CU-xx" and "GU-xx" are carried,
it is 300 mA which is total usage of MJ1, MJ2, or USB-A.
4 +5V
5 SG Signal ground
6 SG
7 RD RS-232C receive data
8 SD RS-232C send data
LAN Connector (LAN)
This port is used for Ethernet connection (100BASE-TX, 10BASE-T).
Specification: comply with IEEE802.3u (100BASE-TX), comply with IEEE802.3 (10BASE-T),
UDP/IP and TCP/IP are supported.
LAN Pin No. Signal Contents
12345678
1 TX+ Ethernet Send (+)
2 TX- Ethernet Send (-)
3 RX+ Ethernet Receive (+)
4 NC Not used
5 NC Not used
6 RX- Ethernet Receive (-)
7 NC Not used
8 NC Not used
Mounting panel
Panel cut-out hole
17.8
10.5
30.0
Fixtures
Mounting
hole
V715+
Mounting panel
Mounting
hole
Fixture dimensions
(Unit: mm)
Display
Display

6
Setting of DIP Switches
Setting of dip switches is as follows. (The following figure shows the condition when the panel is unpacked.)
When setting DIP switch, turn the power off.
DIPSW 1 (CF Auto Load)
Set DIPSW 1 ON when a screen data file saved on a CF card can be auto-loaded.
・Procedure
1. Transfer screen data from the computer to a CF card. (Refer to the Reference Manual (Function) for more
information.)
2. Set DIPSW 1 in the ON position, and insert the CF card that contains the screen data file.
3. Turn the unit on. The screen data is automatically loaded into the FLASH memory of the unit.
DIPSW 2 (CF Cover Access Control)
Specify the state of LED when opening the CF cover.
Normally, keep DIPSW 2 OFF.
DIPSW2 OFF ON
LED Turned off * Illuminating
* When the CF cover is opened during access to CF card, the LED lamps
illuminates until access to CF card is completed.
DIPSW 3,4 (Not used)
Keep OFF.
DIPSW 5,6,7,8 (Terminating Resistance Setting)
・Set DIPSW 7 ON in the case of connecting V7+ to PLC by RS-422/485 (Two-wire system)
・Set DIPSW 5,7 ON in the case of connecting V7+ to PLC by RS-422/485 (Four-wire system)
・Set DIPSW 6 or DIPSW 8 when using MJ1 or MJ2 with the following connection.
- Master station for multi-link 2 connection
- Temperature controller network/PLC2Way connection via RS-485
- Card Recorder: Connection with the CREC (optional)
- Serial extension I/O: Connection with the V-I/O (optional)
- Connection to the V715+ at the termination of V-link connection via RS-485
Terminal resistance of MJ2 (modelar jack 2)
RD terminal resistance of pin No.24 and 25 of CN1
Terminal resistance of MJ1 (modelar jack 1)
SD terminal resistance of pin No.12 and 13 of CN1
(Enlarged view)
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
ON
12345678
Not used
CF auto load
CF cover access control
CN6
U-A U-B
LED
When the CF cover is opened

7
English
Electrical Wiring
Electric shock hazards
Shut the power off before connecting the power supply cable.
Power Supply Cable Connection
Connect the power suppy cable to the terminal on the backside of the unit.
When connecting the power supply cable to the tighten the terminal screw to the following torque.
Screw Size Torque Clamp Terminal (Unit: mm)
M3.5 0.5N m7.1MAX 7.1MAX
The power source must be within the allowable voltage fluctuation.
Use a power source with low noise between the cables or between the ground and the cable.
Use as thick a power cable as possible to minimize drop in voltage.
Keep power supply cables away from high-voltage, large-current carrying cables.
Be sure to attach the terminal cover to the terminal block.
Notes on Usage of 100-240V AC Specifications
Generally, an isolating transformer improves noise resistance. However, if the display unit is far away from the
secondary port of the transformer and noise gets mixed in,
an isolating transformer becomes unnecessary.
If any power voltage fluctuation caused by noise is expected,
it is recommended that a voltage stabilizer (effective in noise
resistance) be used.
Grounding
Be sure to establish a ground of AnyTouch.
(The level of grounding resistance should be less than 100 .)
An independent earth pole shall be used for AnyTouch.
Use a cable which has a nominal cross section of more than 2mm2
for grounding.
Set the grounding point near the AnyTouch to shorten the distance of
grounding cables.
SG and FG are connected inside equipment.
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
V715X+
LN
V715XD+
24 VDC
FG FG
+-
Grounding Grounding
Power supply
24V DC
10%
Power supply
100-240V AC
10%
Power Supply V715+
1.25mm2twisted
Insulation transformer
or
Stabilized transformer
Other
equipment
V715+

8
Notes on Usage of Lithium Battery
The AnyTouch is delivered without inserting the battery connector in the battery holder on the back
of the unit. Be sure to set the battery when using the calendar function or SRAM. Without battery,
the contents in the SRAM or calendar will not be retained.
Specifications
Item Specifications
Battery Specification Lithium primary battery of coin type
Backup Memory SRAM 128 Kbyte
Backup Period 5 years (at the temperature of 25 )
Detection of Voltage for Battery Lowering Available (internal memories allocated)
Calendar Precision Remainder on a month 90 seconds (at the temperature of 25 )
Battery Mounting Procedure
Electric shock hazards
Steps 2 to 5 must be performed when the power to the V715+ is turned off.
1. Turn the unit off.
2. Slide the battery holder cover in the direction of the arrow as shown in the above illustration to open it.
3. Check that the battery is securely attached to the backside of the cover, and connect the battery connector.
4. Close the battery holder cover.
5. Enter a date five years from now for "Battery replacement" on
the sticker on the battery holder.
6. Turn on the power to the V715+ unit and check that the battery
is correctly mounted on the Main Menu screen. When the
battery is not connected, the [SRAM/Clock] switch blinks and
the message "Battery not set" is displayed at the bottom left
corner. When the battery is correctly connected, the [SRAM/
Clock] switch goes out and the message is cleared. When the
battery voltage has dropped, the message "Brownout Battery"
is displayed. It is strongly recommended to replace the battery
immediately even it has not been passed for five years.
Battery Replacement Procedure
About the battery replacement procedure, refer to "V7-BT (Replacement Battery) Operation Instruction" attached to the
battery 'V7-BT'.
F2 F7F6F4F3F1 F5
V715 Series
Ethernet Information
Trans.Speed : 100BASE-T
Stat.No : 192.168.1.68
PORT : 10000
MAC : 0050FF0000D0
2006-1-1 07:23:30
SYSTEM PROG. ver. 1.540
FONT
ver.1.330/1.100/1.000
JAPANESE 32
I/F DRV ver.1.310
MELSEC AnA/N/U
PLC Type : SIEMENSS7
Comment :
Error : Stop
Time-Out :
0.50 sec
Retry :
3
Editor:MJ1
Connection :
1:1
SignalLevel :
RS-232C
PLC Stat.No. :
0
Baud Rate :
19200
Data Length :
7
Stop Bit :
1
Parity : Enen
Send Delay :
0msec
V715X+
Card
Menu
ETHERNET
I/O Test
5111808
SRAM/Clock
Main Menu
System Information
Screen Data
Information
Size
Write down the date of
five years from now.
See operating or maintenance
instruction for type of battery
to be used.
Battery replacement.
Connector of battery
Battery holder
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
CR2450
M
n
O
2
-
L
i
C
E
L
L
3
V
O
L
T
S
J
A
P
A
N
SANYO
CR2450
M
n
O
2
-
L
i
C
E
L
L
3
V
O
L
T
S
J
A
P
A
N
SANYO

9
한글
안전상의 주의
본서는 AnyTouch를안전하게 사용하기 위하여 주의사항 등급을 「위험」, 「주의」로 구분하여 아래와 같은 표시로 나타내
고있습니다.
취급을 잘못한 경우, 사망 또는 중상 초래가 임박한 위험한 상황을 나타냅니다.
취급을 잘못한 경우, 경상 또는 중간 정도의 상해를 초래할 가능성이 있는 상황 및물적 손해의 발생
이예상되는 위험한 상황을 나타냅니다.
또한 로기재한 사항이라도 상황에 따라서는 중대한 결과로 이어질 가능성이 있습니다.
AnyTouch의 터치스위치 등
○ 출력기능을 인명이나 기기의 파손으로 이어지는 상황 또는 긴급용 비상스위치 기능으로
사용하지 마십시오. 또한 터치스위치의 고장에 대응할 수 있는 시스템 설계를 실시해 주십시오. 터치스위치의 고장으
로 기기의 파손 및 고장의 우려가 있습니다.
장치의 조립, 배선작업 및 보수ㆍ점검은 반드시 전원을 끈 후에 실시해 주십시오. 감전 및 파손의 우려가 있습니다.
○
통전중에는 절대로 단자에 접촉하지 마십시오. 감전의 우려가 있습니다.
○
통전, 운전을 실시하는 경우에는 반드시 단자커버를 장착해 주십시오. 단자커버를 장착하지 않으면 감전의 우려가 있
○
습니다.
액정패널의 액체(액정)는 유해물질입니다. 액정패널이 파손된 경우, 유출된 액정을 입에 넣지 마십시오. 피부나 의복
○
에 묻은 경우에는 비누 등으로 씻어내 주십시오.
리튬전지를 사용한 AnyTouch를 사용하는 경우, 전지의 + - 역접속, 충전, 분해, 가압변형, 불속에 투입, 단락은 하지
○
마십시오. 파열, 발화의 우려가 있습니다.
리튬전지를 사용한 AnyTouch를 사용하는 경우, 전지변형, 액누출, 기타 이상을 발견하였을 때는 사용하지 마십시오.
○
파열, 발화의 우려가 있습니다.
백라이트의 수명이 다 되었거나 고장일 때 전원 표시등이 깜박입니다. 그러나 이때에 스크린의 스위치는 사용 가능합
○
니다. 스크린이 어두워지거나 전원 표시등이 깜박일 때에 스크린을 만지지 마십시오.
그렇지 않으면 고장이 나서 기기 사고 및 손상이 일어날 수 있습니다.
포장 개봉시에는 외관 체
○크를 실시해 주십시오. 손상, 변형이 있는 것은 사용하지 마십시오. 화재, 오작동, 고장의 원
인이 됩니다.
원자력 관련, 항공우주 관련, 의료 관련, 교통기기 관련, 승용이동체 관련 또는 이들 시스템의 특수용도로 사용하는
○
경우에는 당사 영업부에 상담해 주십시오.
AnyTouch는 본서 및 관련 매뉴얼 기재의 일반사양 환경에서 사용(보관)해 주십시오. 일반사양 이외의 환경에서 사용
○
하면 화재, 오작동, 제품 파손 또는 열화의 원인이 됩니다.
다음과 같은 장소에서는 사용(보관)하지 마십시오. 고장, 화재의 원인이 됩니다.
○
- 물, 부식 가스, 가연성 가스, 용제, 연삭액, 절삭유 등에 직접 접촉하는 장소
- 고온, 결로, 비바람, 직사광선에 노출되는 장소
- 먼지, 염분, 철분이 많은 장소
- 진동, 충격이 직접 가해지는 장소
V7 Plus 시리즈
V715+ 사용설명서
AnyTouch V715 Plus 시리즈를 구입하여 주셔서 대단히 감사합니다. 먼저 희망하신 상품이 틀림없는지 확인해 주십시오.
올바른 조작을 위해 V715+를사용하기 전에 본사용 설명서를 읽으십시오.
[부속품] V715+ 사용설명서: 1부, 설치금구: 6개, USB 케이블 클램프: 1개
[형식]
15인치 디스플레이
기기 유형
X : TFT 컬러 LCD (XGA 32,768 색상)
전원 공급 유형
없음 : 100-200V AC
D : 24V DC (CE/UL/cUL 준수)

10
기기에 도입시에 AnyTo
○uch의 주전원 단자에 용이하게 접촉되지 않도록 바르게 설치해 주십시오. 감전, 사고의 우려
가 있습니다.
AnyTouch의 설치금구 조이기는 규정 토크 범위에서 실시해 주십시오. 너무 조이면 패널면이 변형될 우려가 있습니다.
○
조임이 느슨하면 낙하, 단락, 오작동의 원인이 됩니다.
전원입력부 단자대의 단자나사 및 설치금구는 조임이 확실하게 되어 있는지 정기적으로 확인해 주십시오. 느슨한 상
○
태에서 사용하면 화재, 오작동의 원인이 됩니다.
전원입력부 단자대의 단자나사 조이기는 0.5N
○m의 토크로 균등하게 조여 주십시오. 조임이 불완전하면 화재, 오작동,
고장의 원인이 됩니다.
AnyTouch는 표시부에 유리를 사용하고 있으므로 낙하시키거나 강한 충격을 가하지 마십시오. 파손의 우려가 있습니
○
다.
AnyTouch의 배선은 정격전압, 정격전력을 고려하여 바르게 단자에 배선해 주십시오. 정격외 전원을 공급하거나 오배
○
선한 경우에는 제품의 파손, 고장, 화재의 원인이 됩니다.
AnyTouch는 반드시 접지를 해 주십시오. FG단자는 D종 접지의 AnyTouch 전용으로 접지해 주십시오. 감전, 화재의
○
원인이 됩니다.
AnyTouch내에 도전선 이물질이 들어가지 않도록 주의해 주십시오. 화재, 고장, 오작동의 원인이 됩니다.
○
AnyTouch를 직접 수리, 분해 또는 개조하지 마십시오. RS Automation Co., Ltd.는 인증받지 않은 사람이 수행한
○
AnyTouch 수리, 분해 또는 개조로 인해 발생하는 모든 손상에 대해 책임지지 않습니다.
끝이 예리한 물건으로 터치패널을 누르지 마십시오.
○
설치, 배선작업 및 보수ㆍ점검은 전문지식이 있는 사람이 실시해 주십시오.
○
배터리에 포함된 리튬 또는 유기용제 등의 연소성 재질로 인해 열, 폭발 또는 화재가 발생하여 부상이나 화재 발생의
○
위험이 있습니다. 관련 매뉴얼을 잘 읽고 지침에 따라 리튬 배터리를 올바르게 취급하십시오.
스크린에서 둘 이상의 지점을 동시에 누르지 마십시오. 누른 두 지점 사이에 스위치가 있으면 해당 스위치가 작동할
○
수 있습니다.
운전중의 설정변경, 강제출력, 기동, 정지 등의 조작은 충분히 안전을 확인한 후에 실시해 주십시오. 조작실수로 인해
○
기기가 작동하여 기계 파손 및 고장의 우려가 있습니다.
AnyTouch가 고장나서 인명과 관련되거나 중대한 손실 발생이 예상되는 설비에 적용하는 경우에는 반드시 안전장치
○
를 설치해 주십시오.
AnyTouch를 폐기할 때는 산업폐기물로 취급해 주십시오.
○
AnyTouch에 접촉하기 전에는 접지된 금속 등에 접촉하여 인체 등에 대전된 정전기를 방전시켜 주십시오. 과대한 정
○
전기는 오작동, 고장의 원인이 됩니다.
CF 카드에 액세스하는 동안에는 LED 램프가 켜집니다(빨간색). LED 램프가 켜진 상태에서 CF 카드를 넣거나 빼지
○
말아야 하며 전원을 끄지 마십시오. CF 카드의 데이터가 손상될 수 있습니다. CF 카드를 넣거나 뺄 때 또는 전원을
끌 때는 먼저 LED 램프가 꺼졌는지 확인하십시오.
UL/c-UL 승인
V715XD+는UL/cUL 승인 제품입니다. (파일 번호: E185413 (UL60950-1), 파일 번호: E303690 (UL1604))
이유형은 다음 4가지 표준을 준수합니다.
- UL60950-1 정보 기술 장비 – 안전 – 제1부: 일반 요구사항
- UL1604 Class 1, Division 2 위험 장소에서의 전기 장비 사용에 대한 표준
- CSA-C22.2 제60950-1호정보 기술 장비 – 안전 – 제1부
- CSA-C22.2 제213-M1987 Class 1, Division 2 위험 장소에서의 불발화 전기 장비의 사용
UL1604/CSA-C22.2 제213호준수 및취급 주의사항
전원, 입력 및 출력 배선은 Class 1 Division 2 배선 방식을 따라야 합니다.
○
- 국가 전기 규약 NFPA 70 제 501-10 (B) 항
○
경고: 폭발 위험: 부품을 임의로 교체하는 것은 Class 1 Division 2의 위반 사항이 될 수 있습니다.
○
경고: 폭발 위험: 안전이 확보되지 않은 장소에서 전기가 공급된 상태에서 회로의 연결을 해제하지 마십시오.
○
경고: 폭발 위험: 위험한 장소에서 모듈을 교체하거나 연결하기 전에 전원을 끄십시오.
○
CE 표시
V715XD+는EMC 지침을 준수합니다.
EN55011 Class A, EN61000-6-2
NK 표준
V715XD+는NIPPON KAIJI KYOKAI에서 NK 표준 인증을 받았습니다.
형식 테스트 번호: 06A014

11
한글
일반사양
항목 V715X+ V715XD+
호환 사양 -
CE 표시:
EN61000-6-2, EN55011 Class A
UL/cUL: UL60950-1, UL1604
NK: 06A014
전원
정격전압 AC100~240V DC 24V
전압허용범위 AC100~240V±10% DC 24V±10%
허용순간정전시간 20ms 이내 1ms 이내
소비전력(최대 정격) 90VA 이하 40W 이하
돌입전류 AC100V: 20A 이하 (10ms 이하)
AC200V: 40A 이하 (10ms 이하)30A 이하 (1ms 이하)
내전압 AC 외부단자와 FG간:
AC1500V, 1분간
DC 외부단자와 FG간:
AC500V, 1분간
절연저항 DC500V, 10MΩ이상
물리적
환경
작동주위온도 0℃~+40℃
보존주위온도 -10℃~+50℃
상대습도 85% RH 이하(단, 결로가 없을 것)
고도 2000m 이하
내용제성 절삭유, 유기용제 부착이 없을 것
사용분위기 내식성 가스가 없고 먼지가 심하지 않을 것, 도전성 먼지가 없을 것
기계적
가동조건
내진동 진동주파수: 10~150Hz, 가속도: 9.8m/s2 (1.0G)
편진폭: 0.075mm, X,Y,Z: 3방향 각1시간
내충격 펄스파형: 정현반파피크
가속도: 147m/s2(15G), X,Y,Z: 3방향 각6회
전기적
가동조건
내노이즈 1500Vp-p
(펄스폭 1μs, 기동시간: 1ns) 1000Vp-p
(펄스폭 1μs, 기동시간: 1ns)
내정전기방전 IEC61000-4-2에준거, 접촉 6kV, 공기중: 8kV
설치조건
접지 D종접지
구조
보호구조: 앞면 패널: IP65 준거(방수패킹 사용시)
뒷면 패널: IP20 준거
형상: 일체형
설치방법: 패널매입설치
냉각방식 자연공냉
무게(kg) 약5.2 약5.0
외형치수 W ×H ×D (mm) 382.8 ×312.8 ×81.1
패널 컷치수(mm) 369.4+0.5
-0 ×299.4+0.5
-0
재질 알루미늄

12
각부 명칭 및치수
단위: mm
1. 디스플레이 9. CF카드용 커넥터(CF)
2. POWER 램프(POWER) *10. 전원입력 단자대
3. 펑션스위치 11. LAN용커넥터(LAN)
4. 통신 인터페이스 유닛용 커넥터(CN5) 12. PLC통신 커넥터(CN1)
5. 증설 메모리용 커넥터(MEMORY) 13. 모듈러 커넥터(MJ1, MJ2)
6. 옵션 유닛용 커넥터(CN7) 14. USB-B (슬레이브 포트)
7. 전지 홀더 15. USB-A (마스터 포트)
8. 딥스위치 16. 설치구멍
* 전원이 켜져 있을 때에 녹색으로 켜집니다. 백라이트에 에러가 발생했을 때에 깜박입니다.
씨리얼 커넥터(CN1)
커넥터(CN1)는PLC와의 통신(RS-232C, RS-422/485)에사용합니다. 핀배치는 아래와 같습니다.
CN1 (Dsub 25pin Female) 핀No. 신호명 내용
1
14
13
25
1 FG 프레임 그라운드
2 SD RS-232C 송신 데이터
3 RD RS-232C 수신 데이터
4 RS RS-232C RS 송신요구
5 CS RS-232C CS 송신가능
6미사용
7 SG 시그널 그라운드
8미사용
9 +5V 사용불가
10 0V 사용불가
11 미사용
12 +SD RS-422 송신 데이터(+)
13 -SD RS-422 송신 데이터(-)
14 +RS RS-422 RS 송신 데이터(+)
15 미사용
16 미사용
17 -RS RS-422 RS 송신 데이터(-)
18 -CS RS-422 CS 수신 데이터(-)
19 +CS RS-422 CS 수신 데이터(+)
20 미사용
21 - 사용불가
22 - 사용불가
23 미사용
24 +RD RS-422 수신 데이터(+)
25 -RD RS-422 수신 데이터(-)
1
23
9
F1 F2 F3 F4 F5 F6 F7
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
15141310 11 12
16
45 6
7
8
312.8
382.8
298.4
368.4
81.1 8.3
47.8
43.4

13
한글
* 정전기를 방지하기 위해 고정 패널을 접지시키십시오.
3. 개스킷이 장치와 고정 패널 사이에 완전히 고정되도록 개스킷을 장착합니다.
설치각도
설치각도는 0°~135°범위내로 설치해 주십시오.
모듈러 잭(MJ1/MJ2)
화면전송용 케이블 및온도조절기, 바코드 리더, CREC, V-I/O 등을 접속하기 위한 커넥터입니다.
모듈러 잭의 핀배치는 아래와 같습니다.
MJ1/MJ2 핀No. 신호명 내용
12345678
1 +SD/RD RS-485 데이터(+)
2 -SD/RD RS-485 데이터(-)
3 +5V 외부공급 +5V *
* 출력 전원 공급(+5V)에대한 최대 전류는 MJ1, MJ2 또는
USB-A의전체 사용량인 500mA입니다. "CU-xx" 및"GU-
xx"가수행되는 경우에는 MJ1, MJ2 또는 USB-A의총사
용량인 300mA입니다.
4 +5V
5 SG 시그널 그라운드
6 SG
7 RD RS-232C 수신 데이터
8 SD RS-232C 송신 데이터
LAN용커넥터(LAN)
Ethernet(10BASE-T, 100BASE-TX)에접속할 때사용합니다.
사양:IEEE802.3 (u) 준거(100BASE-TX), IEEE802.3 준거(10BASE-T), UDP/IP 및TCP/IP에대응
LAN 핀No. 신호명 내용
12345678
1 TX+ Ethernet 송신신호(+)
2 TX- Ethernet 송신신호(-)
3 RX+ Ethernet 수신신호(+)
4 NC 미사용
5 NC 미사용
6 RX- Ethernet 수신신호(-)
7 NC 미사용
8 NC 미사용
MJ1/MJ2 및LAN 커넥터는 모두 8핀모듈러 잭입니다. 명판을 확인하여 오삽입하지 않도록 주의해 주
십시오.
USB 포트 (USB ver.1.1)
형식 A(마스터 포트): USB 프린터 및 CF 카드 리더/라이터용
○
형식 B(슬레이브 포트): 컴퓨터 연결용(화면 데이터 전송)
○
* USB 케이블용 클램프의 사용법에 대해서는 "V715+ Hardware Specifications"을참조하십시오.
설치방법
1. 판금패널(최대 판후 5mm)에V715 Plus 시리즈를 삽입합니다.
2. 부속된 설치금구(설치금구수: 6개)를V715 Plus 시리즈의
설치구멍에 삽입하고 조임나사로 고정해 주십시오.
(조임토크: 0.7~1.0Nm)
CN5
CN7
MEMORY
MJ2 U-B
CF
MJ1 U-A
CN1
LAN
설치금구
V715+ 본체
판금패널
설치구멍 설치구멍
판금패널
패널 컷구멍
표시면
표시면
17.8
10.5
30.0
설치금구 치수
(단위: mm)

14
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
ON
12345678
CF 자동로드 미사용
MJ2 (모듈러 잭2) 종단저항
CN1 24, 25핀간의 RD 종단저항
MJ1 (모듈러 잭1) 종단저항
CN1 12, 13핀간의 SD 종단저항
딥스위치
딥스위치의 설정은 아래와 같습니다. (아래 그림: 공장출하시 상태)
딥스위치를 설정할 때는 본체 전원을 OFF로한후에 실시해 주십시오.
DIPSW1(CF 자동로드)
○
CF 카드에 저장된 화면 데이터 파일을 자동 로드할 수있을 때DIPSW 1을ON으로 설정합니다.
절차
1. 화면 데이터를 컴퓨터에서 CF 카드로 전송합니다(자세한 내용은 레퍼런스 매뉴얼(기능) 참조).
2. DIPSW1을ON 위치로 설정하고, 화면 데이터 파일이 들어 있는 CF 카드를 넣으십시오.
3. 기기를 켜십시오. 화면 데이터가 자동으로 기기의 FLASH 메모리로 로드됩니다.
DIPSW2 (CF 커버 액세스 제어)
○
CF 커버를 열때LED 상태를 지정합니다.
일반적으로 DIPSW2를OFF로설정합니다.
CF 커버를 열었을 때
DIPSW2 OFF ON
LED 꺼짐*켜짐
* CF 카드에 액세스하는 도중에 CF 커버가 열리면, CF 카드 액세스가
완료될 때까지 LED 램프가 켜집니다.
DIPSW3, 4 미사용(미사용)
○
OFF로 합니다.
DIPSW5, 6, 7, 8 (종단저항 설정)
○
CN1에서 PLC와RS-422/485(2선식)로접속하는 경우, DIPSW7을ON합니다.
CN1에서 PLC와RS-422/485(4선식)로접속하는 경우, DIPSW5, 7을ON합니다.
MJ1(MJ2)으로 아래의 접속을 하는 경우에 DIPSW6(DIPSW8)을ON합니다.
- 멀티링크2에서 접속하는 경우의 마스터
- RS-485로온도조절 넷/PLC 2Way 접속하는 경우
- 카드 레코더: CREC(옵션)을사용하는 경우
- 씨리얼 증설 I/O: V-I/O(옵션)를사용하는 경우
- RS-485로V-Link 접속하는 경우의 종단에 있는 V715 Plus 시리즈
CF 커버 액세스 제어
(확대 표시)
CN6
U-A U-B
LED

15
한글
접지 배선
AnyTouch는반드시 접지를 해주십시오.
(접지공사는 D종접지, 접지저항 100Ω이하)
접지는 전용접지로 해 주십시오.
○
접지용 케이블은 공칭단면적 2mm
○2 이상의 것을 사용해 주십시오.
접지점은 본체 근처로 하여 접지선의 거리를 짧게 해 주십시오.
○
SG 및 FG는 장비 안쪽에 접속됩니다.
○
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
V715X+
LN
V715XD+
24 VDC
FG FG
+-
전원
AC100-240V
±10%
전원
DC24V
±10%
접지 접지
V715+ 다른 기기
전원케이블 배선과 접지에 대하여
감전의 우려가 있습니다. 전원케이블의 배선은 전원 OFF 상태에서 실시해 주십시오.
전원케이블 배선
전원케이블은 본체 배면의 단자에 접속합니다.
○
전원을 배선하는 경우의 단자나사 조이기는 아래 값으로 실시해 주십시오.
○
나사 사이즈 조임토크 압착단자(단위: mm)
M3.5 0.5Nm7.1 MAX 7.1 MAX
전원은 허용전원전압 변동범위내에서 사용해 주십시오.
○
선간 및 대지간 모두 노이즈가 적은 전원을 사용해 주십시오.
○
전원선은 전압강하를 작게 하기 위해 가능한 한 굵은 선을 사용해 주십시오.
○
전원 공급 케이블을 고전압 및 고전류 케이블로부터 멀리하십시오.
○
단자대에는 반드시 단자커버를 장착해 주십시오.
○
AC100~240V 사양에서 특히 주의할 점
일반적으로 절연 트랜스를 넣음으로써 내노이즈성은 개선되지
○
만 트랜스의 2차측에서 V715 Puls 시리즈까지의 거리가 길거나,
또는 노이즈가 혼입되기 쉬운 상태라면 넣는 의미가 없습니다.
노이즈나 전원변동이 있는 경우에는 안정화 트랜스(내노이즈성
○
에도 효과가 있음)를 넣을 것을 권장합니다.
전원 절연 트랜스 또는
안정 트랜스
1.25 mm2
트위스트한다
V715+로

16
CN5
CN7
MEMORY
MJ2U-B
CF
MJ1U-A
CN1LAN
CR2450
M
n
O
2
-
L
i
C
E
L
L
3
V
O
L
T
S
J
A
P
A
N
SANYO
CR2450
M
n
O
2
-
L
i
C
E
L
L
3
V
O
L
T
S
J
A
P
A
N
SANYO
전지 홀더
전지 커넥터 5년후의 연월일을 기입
코인형 리튬전지에 대하여
공장출하시, 본체 뒷면의 전지홀더내의 전지는 커넥터가 세트되어 있지 않습니다.
캘린더 기능 및SRAM을사용할 때는 반드시 전지를 세트해 주십시오. 전원이 공급되지 않으면 SRAM
과캘린더의 내용이 유지되지 않습니다.
시계 및백업 메모리 사양
항목 사양
전지 사양 코인형 리튬 1차전지
백업 메모리 SRAM 128Kbyte
백업 기간 5년(주위온도 25℃)
전원전압저하 검출기능 있음(내부 메모리 분할장착)
캘린더 정밀도 월오차 ±90초(주위온도 25℃)
전지 세트방법
감전의 우려가 있습니다.
아래 2.~5.의전지 세트작업은 V715+ 본체의 전원이 OFF 상태에서 실시해 주십시오.
1. 본체 전원을 OFF합니다.
2. 전지홀더의 커버를 ↑방향(위그림 참조)으로 슬라이드시키면서 엽니다.
3. 전지가 커버 뒤에 단단히 실장되어 있는지 확인한 후, 전지의 커넥터를 장착합니다.
4. 전지홀더의 커버를 닫습니다.
5. 전지홀더 씰의 「Battery replacement」란에 5년후의 연월일을
기입합니다.
6. V715+ 본체의 전원을 ON으로 하여 전지가 세트되었는지를 본
체의 「Main Menu」화면에서 확인합니다. 전지가 세트되어 있
지않은 경우, 「SRAM/Clock」스위치가 점멸하고 왼쪽 아래에
「Battery not set」메시지가 표시됩니다. 세트되면 「SRAM/
Clock」스위치는 소등되고 메시지는 소멸됩니다.
전지의 전압이 저하되었을 때는 「Brownout Battery」라는 메시
지가 표시됩니다. 5년이내라도 신속히 전지를 교환해 주십시오.
전지 교환방법
전지 교환방법에 대한 자세한 사항은V7-BT (Replacement Battery) Operation Instruction을참조해 주십시오.
See operating or maintenance
instruction for type of battery
to be used.
Battery replacement.
F2 F7F6F4F3F1 F5
V715 Series
Ethernet Information
Trans.Speed : 100BASE-T
Stat.No : 192.168.1.68
PORT : 10000
MAC : 0050FF0000D0
2006-1-1 07:23:30
SYSTEM PROG. ver. 1.540
FONT
ver.1.330/1.100/1.000
JAPANESE 32
I/F DRV ver.1.310
MELSEC AnA/N/U
PLC Type : SIEMENSS7
Comment :
Error : Stop
Time-Out :
0.50 sec
Retry :
3
Editor:MJ1
Connection :
1:1
Signal Level :
RS-232C
PLC Stat.No. :
0
Baud Rate :
19200
Data Length :
7
Stop Bit :
1
Parity : Enen
Send Delay :
0msec
V715X+
Card
Menu
ETHERNET
I/O Test
5111808
SRAM/Clock
Main Menu
System Information
Screen Data
Information
Size


Publication AnyTouchV7-IN006A-V715-EK - November 2010


Copyright © 2010 RS Automation Co., Ltd. All rights reserved.
Other manuals for AnyTouch V7 Plus Series
3
This manual suits for next models
1
Table of contents
Other RS Automation Touch Panel manuals