manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. RS Automation
  6. •
  7. Touch Panel
  8. •
  9. RS Automation AnyTouch V7 Plus Series User manual

RS Automation AnyTouch V7 Plus Series User manual

Other manuals for AnyTouch V7 Plus Series

3

This manual suits for next models

1

Other RS Automation Touch Panel manuals

RS Automation AnyTouch V7 Plus Series User manual

RS Automation

RS Automation AnyTouch V7 Plus Series User manual

RS Automation AnyTouch V8 Plus Series User manual

RS Automation

RS Automation AnyTouch V8 Plus Series User manual

RS Automation AnyTouch V8 Plus Series User manual

RS Automation

RS Automation AnyTouch V8 Plus Series User manual

Popular Touch Panel manuals by other brands

Endress+Hauser ria45 operating instructions

Endress+Hauser

Endress+Hauser ria45 operating instructions

Wincomm WLP-7B20 Series user manual

Wincomm

Wincomm WLP-7B20 Series user manual

NEC ME Series user manual

NEC

NEC ME Series user manual

VIPA TP 606C CAN manual

VIPA

VIPA TP 606C CAN manual

Acnodes PC 1080 quick guide

Acnodes

Acnodes PC 1080 quick guide

Extron electronics TLP 700MV user guide

Extron electronics

Extron electronics TLP 700MV user guide

AMX AXT-EL Plus Dimensional drawing

AMX

AMX AXT-EL Plus Dimensional drawing

LEGRAND 67285 installation manual

LEGRAND

LEGRAND 67285 installation manual

FlowLine Data loop quick start

FlowLine

FlowLine Data loop quick start

ALPEX AEx-8 P Series user manual

ALPEX

ALPEX AEx-8 P Series user manual

Harman AMX MODERO S MSD-701-L2 quick start guide

Harman

Harman AMX MODERO S MSD-701-L2 quick start guide

ADT 6270ADT Installation and setup gude

ADT

ADT 6270ADT Installation and setup gude

Acnodes PC 1150 installation guide

Acnodes

Acnodes PC 1150 installation guide

AMX ViewPoint quick start guide

AMX

AMX ViewPoint quick start guide

AIS IP10IA99 series user guide

AIS

AIS IP10IA99 series user guide

IBASE Technology ASTUT-152-RE1S user manual

IBASE Technology

IBASE Technology ASTUT-152-RE1S user manual

YASKAWA TP 610C manual

YASKAWA

YASKAWA TP 610C manual

B&R Power Panel C Series user manual

B&R

B&R Power Panel C Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
English
한글
3333NK0
V7 Plus Series
V706+ OPERATING INSTRUCTIONS
Make sure that the delivered unit conforms to your requirement, and also check for any missing or damaged parts.
Before using this V706+, be sure to read this OPERATING INSTRUCTIONS thoroughly to ensure proper operation.
[Accessories] V706+ OPERATING INSTRUCTIONS: 1 copy, Fixtures: 4 pcs
[Models]
Notes on Safe Usage
In this "V706+ OPERATING INSTRUCTIONS", you will find various notes categorized under the following two levels with the
signal words "Danger" and "Caution."
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious
injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury and could cause property damage.
Even some items indicated may also result in a serious accident.
Never use the output function of AnyTouch for operations that may threaten human life or to damage the system,
such as switches to be used in case of emergency. Please design the system so that it can cope with malfunction of
a touch switch. A malfunction of the touch switch will result in machine accident or damage.
Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection.
Otherwise, electrical shock or damage may occur.
Never touch any terminals while the power is on. Otherwise, electric shock may occur.
You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without the
terminal cover in place, an electric shock may occur.
The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, never swallow the leaked
liquid crystal. If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly.
For AnyTouch using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit, nor reverse the
polarity of the battery, and never dispose of the battery in fire. Failure to follow these conditions will lead to explosion
or ignition.
For AnyTouch using a lithium battery, never use a battery that is deformed, leaks, or shows any other signs of
abnormality. Failure to follow these conditions will lead to explosion or ignition.
Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found.
Failure to do so may lead to fire, damage or malfunction.
For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile
installations, please consult your local distributor.
Operate (or store) AnyTouch under the conditions indicated in this manual and related manuals. Failure to do so
could cause fire, malfunction, physical damage or deterioration.
Understand the following environmental limits for use and storage of AnyTouch. Otherwise, fire or damage to the unit
may result.
- Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or
cutting oil can come into contact with the unit.
- Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight.
- Avoid locations where excessive dust, salt, and metallic particles are present.
- Avoid installing the unit in a location where vibration or physical shock may be transmitted.
5.7 inch display
Device type
T : TFT color LCD (QVGA, 32,768 colors)
C : STN color LCD (QVGA, 32,768 colors)
M : STN color LCD (QVGA, monochrome 8-grade) Touch switch type
M : matrix resistance film type
(None) : analog resistance film type
Power supply type
D : 24V DC (Comply with CE/UL/cUL)
2
Equipment must be correctly mounted so that the main terminal of AnyTouch will not be touched inadvertently.
Otherwise, an accident or electric shock may occur.
Tighten the fixtures of the AnyTouch with a torque in the specified range. Excessive tightening may distort the panel
surface. Loose tightening may cause AnyTouch to come off, malfunction or be short-circuited.
Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened.
Loosened screws may result in fire or malfunction.
Tighten terminal screws on the power supply terminal block equally to a torque of 0.5 N m. Improper tightening of
screws may result in fire, malfunction, or trouble.
AnyTouch has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen may be
damaged.
Connect the cables correctly to the terminals of AnyTouch in accordance with the specified voltage and wattage.
Over-voltage, over-wattage or incorrect cable connection could cause fire, malfunction or damage to the unit.
Be sure to establish a ground of AnyTouch. Ground FG terminal which must be used for the unit. Otherwise, electric
shock or a fire may occur.
Prevent any conductive particles from entering into AnyTouch. Failure to do so may lead to fire, damage or
malfunction.
After wiring is finished, remove the paper used as a dust cover before starting to operate AnyTouch. Operation with
the cover attached may result in accident, fire, malfunction, or trouble.
Do not attempt to repair, disassemble or modify AnyTouch at your site. Ask RS Automation Co., Ltd. or the designated
contractor for repair. Otherwise, it may cause a malfunction.
RS Automation Co., Ltd. is not responsible for any damages resulting from repair, overhaul or modification of
AnyTouch that was performed by an unauthorized person.
Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen.
Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection.
For AnyTouch using a lithium battery, handle the battery with care. The combustible materials such as lithium or
organic solvent contained in the battery may generate heat, explode, or catch fire, resulting in personal injury or fire.
Read related manuals carefully and handle the lithium battery correctly as instructed.
When using a AnyTouch that has analog switch resolution with resistance film, do not press two or more points on the
screen at the same time. If there is a switch between the two pressed points, it may be activated.
Take safety precautions during such operations as setting change during running, forced output, start, and stop. Any
misoperation may cause unexpected machine motions, resulting in machine accident or damage.
In facilities where a failure of AnyTouch could lead to accident threatening human life or other serious damage, be
sure that the facilities are equipped with adequate safeguards.
At the time of disposal, AnyTouch must be treated as industrial waste.
Before touching AnyTouch, discharge static electricity from your body by touching grounded metal. Excessive static
electricity may cause malfunction or trouble.
UL/c-UL Approval
The V706 Plus series is UL/cUL-approved. (File No. : E256956(UL60950-1))
This series conforms to the following standards.
・UL60950-1 Information Technology Equipment - Safety - Part 1: General Requirements
・CSA-C22.2 No. 60950-1 Information Technology Equipment - Safety - Part 1
3
English
Specifications
Item Specifications
Power Supply
Rated Voltage 24V DC
Permissible Range of Voltage 24V DC 10%
Permissible Momentary
Power Failure within 1ms
Demand (maximum rating) 16W or less
Rushed Electric Current 20A or less (with a rise time 0.1ms)
With-stand voltage DC external terminals to FG: 500V AC per minute
Insulation Resistance 500V DC, 10M or more
Physical Environment
Ambient Temperature 0 to +50 *
Storage Ambient Temperature -10 to +60
Relative Humidity 85% RH or less (without dew condensation)
Solvent Resistance No cutting oil or no organic solvent to cling to the unit
Atmosphere No corrosive gas, not so much excessive dust and no conductive
dust
Mechanical
Working
Conditions
Vibration Resistance Vibration frequency: 10 to 150Hz, Acceleration: 9.8m/s2(1.0G),
Half-amplitude: 0.075mm, 3 directions of X, Y and Z: one hour
Shock Resistance Pulse shape: Sine half wave, Peak acceleration: 147m/s2(15G),
3 directions of X, Y and Z: 6 times
Electrical
Working
Conditions
Noise Resistance Noise voltage: 1000Vp-p, noise width: 1 s, Rise time 1ns
Static Electricity Discharge
Resistance Adhere to IEC61000-4-2, Contact: 6kV, Air: 8kV
Mounting Conditions
Grounding Grounding resistance: less than 100
Structure
Protection structure: front panel complies with IP65
(when using gasket)
rear cabinet complies with IP20
Form: in a body
Mounting procedure: inserted in a mounting panel
Cooling System Cooling naturally
Weight Unit only: approx. 680 g, with DU-01 installed: approx. 820 g
Dimensions W X H X D (mm) Unit only: 182.5 ×138.8 ×42.5
with DU-01 installed: 182.5 ×138.8 ×64.0
Panel Cut-out (mm) 174.0 +0.5
-0 X 131.0 +0.5
-0
Case Color BLACK (equivalent to the Munsell color system N2.0)
Material PC/PS
* As for V706C+ and V706M+, operation for long hours at ambient temperatures of 40 to 50 may degrade the
display quality, such as lowering contrast.
4
Names of Components and Dimensions
Dimensions (unit : mm)
1. Display 8. USB-B (slave port)
2. Power lamp (POWER) * 9. USB-A (master port)
3. Function switches 10. Power supply terminal block
4. Option unit connector (CN1) 11. Mounting holes
5. Battery holder 12. DIP switch
6. Modular jack connector (MJ1) 13. Slide switch
7. Modular jack connector (MJ2)
* Power lamp illuminates (green) when the power is supplied.
The lamp illuminates (orange) when the voltage of the battery set in the AnyTouch has become low.
6
182.5
138.8
173.6
130.8
42.5
1. 2.3.
4.
5.
6. 7. 8. 9. 10.
11.
12.13.
Modular Jack (MJ1/MJ2)
This port is used for such connection as data transfer, temperature controller network, bar code reader, CREC, and V-I/O,
etc. The pin arrangement of modular jack is as follows:
MJ1 Pin No. Signal Contents
1 +SD/RD RS-485 data (+)
2 -SD/RD RS-485 data (-)
3 +5V Output power supply
Max. 150 mA *
4 +5V
5 SG Signal ground
6 SG
7 RD RS-232C receive data
8 SD RS-232C send data
* The maximum current for the output power supply (+5 V) is 150 mA when MJ1 or MJ2 is used.
5
English
USB Port (USB version 1.1)
Type A (master port)
For USB printer and CF card reader/writer
Type B (slave port)
For computer connection (screen data transfer)
Mounting Procedure
Mounting Procedure
1. Insert the unit into the mounting panel (max. thick: 5 mm).
* To prevent static electricity, be sure to connect the mounting panel to the ground.
3. Mount the gasket so that it will be sandwiched securely
between the unit and the mounting panel.
Mounting Angle
The unit shall be installed within the angle of 0 to 135 degrees.
Modular Jack (MJ2)
This port is used for PLC connection. And it is also used for such connection as data transfer, temperature controller
network, bar code reader, CREC, and V-I/O, etc. when using the optional unit, 'DU-01'. The pin arrangement of modular
jack is as follows:
MJ2 Pin No. Signal Contents Slide switch
1 *1 +SD/RD RS-485 data (+) upper
+SD RS-422 send data (+) lower
2 *1 -SD/RD RS-485 data (-) upper
-SD RS-422 send data (-) lower
3 +5V Output power supply
Max. 150 mA *2 upper, lower
4 +5V
5 SG Signal ground upper, lower
6 SG
7 *1 RD RS-232C receive data upper
+RD RS-422 receive data (+) lower
8 *1 SD RS-232C send data upper
-RD RS-422 receive data (-) lower
*1 The signal can be set by the slide switch.
Upper position: RS-232C/RS-485
Lower position: RS-422 (as default)
*2 The maximum current for the output power
supply (+5 V) is 150 mA when MJ1 or MJ2
is used.
2. Insert four fixtures attached to the V706+ into the
mounting holes, and tighten them with the locking
screws. (Torque: 0.3 to 0.5N m)
Mounting panel
Panel cut-out hole
17.8
10.5
30.0
Fixtures
Mounting
hole
V706+
Mounting panel
Mounting
hole
Fixture dimensions
(Unit: mm)
Display
Display
Slide switch
upper
lower
6
1234
Setting of DIP Switches
Setting of dip switches is as follows. (The following figure shows the condition when the panel is unpacked.)
When setting DIP switch, turn the power off.
DIPSW 1, 2, 3 (Terminating Resistance Setting)
Set the terminating resistance for RS-422/485 connection.
MJ1 can be used for RS-232C or RS-485 (2-wire) connection.
For the following connections, set DIPSW 1 to the ON position.
- Master station for multi-link 2 connection
- Temperature controller network/PLC2Way connection via RS-485
- Card Recorder: Connection with the CREC (optional)
- Serial extension I/O: Connection with the V-I/O (optional)
- Connection to the V706+ at the termination of V-link connection via RS-485
MJ2 can be used for RS-232C or RS-422 (4-wire) connection.
- For connection to the PLC through the RS-422 interface (4-wire connection) at MJ2, set DIPSW 2 and 3 to the
ON position.
- For connection to the PLC through the RS-422 interface (2-wire connection) at MJ2, set DIPSW 3 to the ON
position.
DIPSW 4 (CF Auto Load)
A screen data file saved on a CF card can be auto-loaded as described below.
1. Transfer screen data from the computer to a CF card. (Refer to the Reference Manual (Function) for more
information.)
2. Set DIPSW 4 in the ON position, and insert the CF card that contains the screen data file.
3. Turn the unit on. The screen data is automatically loaded into the FLASH memory of the unit.
MJ1 (modular jack 1) send/receive signal terminating resistor
MJ2 (modular jack 2) send signal terminating resistor
MJ2 (modular jack 2) receive signal terminating resistor
CF auto load
(Enlarged view)
7
English
Electrical Wiring
Electric shock hazards
Shut the power off before connecting the power supply cable.
Power Supply Cable Connection
Connect the power suppy cable to the terminal on the backside of the unit.
When connecting the power supply cable, tighten the terminal screw to the following torque.
Screw Size Torque Clamp Terminal (Unit: mm)
M3.5 0.5N m7.1MAX 7.1MAX
The power source must be within the allowable voltage fluctuation.
Use a power source with low noise between the cables or between the ground and the cable.
Use as thick a power cable as possible to minimize drop in voltage.
Keep powersupply cables away from high-voltage, large-current carrying cables.
Be sure to attach the terminal cover to the terminal block.
Grounding
Be sure to establish a ground of AnyTouch.
(The level of grounding resistance should be less than 100 .)
An independent earth pole shall be used for AnyTouch.
Use a cable which has a nominal cross section of more than 2mm2
for grounding.
Set the grounding point near the AnyTouch to shorten the distance of
grounding cables.
Power supply
24V DC
10%
Grounding
V706+ Other
equipment
Notes on Usage of Lithium Battery
The AnyTouch is delivered without inserting the battery connector in the battery holder on the back of
the unit. Be sure to set the battery when using the calendar function or SRAM. Without battery, the
contents in the SRAM or calendar will not be retained.
Specifications
Item Specifications
Battery Specification Lithium primary battery of coin type
Backup Memory SRAM 128 Kbyte
Backup Period 5 years (at the temperature of 25 )
Detection of Voltage for Battery Lowering Available (internal memories allocated)
Calendar Precision Remainder on a month 90 seconds (at the temperature of 25 )
8
Battery Mounting Procedure
Electric shock hazards
Steps 2 to 5 must be performed when the power to the V706+ is turned off.
1. Turn the unit off.
2. Slide the battery holder cover in the direction of the arrow as shown in the above illustration to open it.
3. Check that the battery is securely attached to the backside of the cover, and connect the battery connector.
4. Close the battery holder cover.
5. Enter a date five years from now for "Battery replacement" on
the sticker on the battery holder.
6. Turn on the power to the V706+ unit and check that the battery
is correctly mounted on the Main Menu screen. When the
battery is not connected, the [SRAM/Clock] switch blinks and
the message "Battery not set" is displayed at the bottom left
corner. When the battery is correctly connected, the [SRAM/
Clock] switch goes out and the message is cleared. When the
battery voltage has dropped, the message "Brownout Battery"
is displayed. It is strongly recommended to replace the battery
immediately even it has not been passed for five years.
Battery Replacement Procedure
About the battery replacement procedure, refer to "V7-BT+ (Replacement Battery) Operation Instruction" attached to the
battery 'V7-BT+'.
About the Label on the Back
The label on the back of AnyTouch denotes the following:
Battery holder
Connector of battery Write down the date of
five years from now.
CE Mark:
The V706 Plus series complies with EMC directive:
EN55011 Class A, EN61000-6-2.
UL/cUL Mark:
The V706 Plus series is UL/cUL-approved.
File No. : E256956 (UL60950-1)
RS Automation Co., Ltd.
Made in Japan
TYPE : V706TD+
INPUT : 24VDC
CURRENT : 0.6A
Ser No. : 3080058 a
Type
Voltage
Current
Serial number CE mark
UL/cUL mark
9
한글
3333NK0
안전상의 주의
본서는 AnyTouch를안전하게 사용하기 위하여 주의사항 등급을 「위험」, 「주의」로 구분하여 아래와 같은 표시로 나타내
고있습니다.
취급을 잘못한 경우, 사망 또는 중상 초래가 임박한 위험한 상황을 나타냅니다.
취급을 잘못한 경우, 경상 또는 중간 정도의 상해를 초래할 가능성이 있는 상황 및물적 손해의 발생
이예상되는 위험한 상황을 나타냅니다.
또한 로기재한 사항이라도 상황에 따라서는 중대한 결과로 이어질 가능성이 있습니다.
○AnyTouch의터치스위치 등출력기능을 인명이나 기기의 파손으로 이어지는 상황 또는 긴급용 비상스위치 기능으로
사용하지 마십시오. 또한 터치스위치의 고장에 대응할 수있는 시스템 설계를 실시해 주십시오. 터치스위치의 고장으로
기기의 파손 및고장의 우려가 있습니다.
○장치의 조립, 배선작업 및보수ㆍ점검은 반드시 전원을 끈후에 실시해 주십시오. 감전 및파손의 우려가 있습니다.
○통전중에는 절대로 단자에 접촉하지 마십시오. 감전의 우려가 있습니다.
○통전, 운전을 실시하는 경우에는 반드시 단자커버를 장착해 주십시오. 단자커버를 장착하지 않으면 감전의 우려가 있습
니다.
○액정패널의 액체(액정)는유해물질입니다. 액정패널이 파손된 경우, 유출된 액정을 입에 넣지 마십시오. 피부나 의복에
묻은 경우에는비누 등으로 씻어내 주십시오.
○리튬전지를 사용한 AnyTouch를사용하는 경우, 전지의 + - 역접속, 충전, 분해, 가압변형, 불속에 투입, 단락은 하지 마십
시오. 파열, 발화의 우려가 있습니다.
○리튬전지를 사용한 AnyTouch를사용하는 경우, 전지변형, 액누출, 기타 이상을 발견하였을 때는 사용하지 마십시오.
파열, 발화의 우려가 있습니다.
V7 Plus
시리즈
V706+
사용설명서
AnyTouch V706 Plus 시리즈를 구입하여 주셔서 대단히 감사합니다. 먼저 희망하신 상품이 틀림없는지 확인해 주십시오.
올바른 조작을 위해 V706+을사용하기 전에 본사용 설명서를 읽으십시오.
[부속품] 사용설명서(본서) 1부, 설치금구 4개
[형식]
5.7 인치 디스플레이
기기 유형
T: TFT 컬러 LCD (QVGA, 32,768 색상)
C: STN 컬러 LCD (QVGA, 32,768 색상)
M: STN 컬러 LCD (QVGA, 모노크롬 8단계)터치 스위치 유형
M: 매트릭스 저항 필름 유형
(없음): 아날로그 저항 필름 유형
전원 공급 유형
D: 24V DC (CE/UL/cUL 준수)
10
○포장 개봉시에는 외관 체크를 실시해 주십시오. 손상, 변형이 있는 것은 사용하지 마십시오. 화재, 오작동, 고장의 원인
이됩니다.
○원자력 관련, 항공우주 관련, 의료 관련, 교통기기 관련, 승용이동체 관련 또는 이들 시스템의 특수용도로 사용하는 경우
에는 당사 영업부에 상담해 주십시오.
○AnyTouch는본서 및관련 매뉴얼 기재의 일반사양 환경에서 사용(보관)해주십시오. 일반사양 이외의 환경에서 사용하
면화재, 오작동, 제품 파손 또는 열화의 원인이 됩니다.
○다음과 같은 장소에서는 사용(보관)하지 마십시오. 고장, 화재의 원인이 됩니다.
- 물, 부식 가스, 가연성 가스, 용제, 연삭액, 절삭유 등에 직접 접촉하는 장소
- 고온, 결로, 비바람, 직사광선에 노출되는 장소
- 먼지, 염분, 철분이 많은 장소
- 진동, 충격이 직접 가해지는 장소
○기기에 도입시에 AnyTouch의주전원 단자에 용이하게 접촉되지 않도록 바르게 설치해 주십시오. 감전, 사고의 우려가
있습니다.
○AnyTouch의설치금구 조이기는 규정 토크 범위에서 실시해 주십시오. 너무 조이면 패널면이 변형될 우려가 있습니다.
조임이 느슨하면 낙하, 단락, 오작동의 원인이 됩니다.
○전원입력부 단자대의 단자나사 및설치금구는 조임이 확실하게 되어 있는지 정기적으로 확인해 주십시오. 느슨한 상태
에서 사용하면 화재, 오작동의 원인이 됩니다.
○전원입력부 단자대의 단자나사 조이기는 0.5Nm의토크로 균등하게 조여 주십시오. 조임이 불완전하면 화재, 오작동,
고장의 원인이 됩니다.
○AnyTouch는표시부에 유리를 사용하고 있으므로 낙하시키거나 강한 충격을 가하지 마십시오. 파손의 우려가 있습니다.
○AnyTouch에의 배선은 정격전압, 정격전력을 고려하여 바르게 단자에 배선해 주십시오. 정격외 전원을 공급하거나 오배
선한 경우에는 제품의 파손, 고장, 화재의 원인이 됩니다.
○AnyTouch는반드시 접지를 해주십시오. FG단자는 D종접지의 AnyTouch 전용으로 접지해 주십시오. 감전, 화재의 원
인이 됩니다.
○AnyTouch내에 도전선 이물질이 들어가지 않도록 주의해 주십시오. 화재, 고장, 오작동의 원인이 됩니다.
○배선 종료후에는 AnyTouch의먼지방지지를 제거하고 운전해 주십시오. 먼지방지지를 부착한 채로 운전하면 화재, 고장,
오작동, 고장의 원인이 됩니다.
○AnyTouch의수리ㆍ분해ㆍ개조는 현장에서는 절대로 실시하지 말고 당사 또는 당사 지정업자에게 수리를 의뢰해 주십
시오. 고장의 원인이 됩니다.
○AnyTouch의수리ㆍ분해ㆍ개조를 당사 이외 또는 당사 지정 이외의 제3자가 실시한 경우, 그것이 원인으로 발생한 손해
등에 대해서는 책임을 지지 않으므로 양지하여 주십시오.
○끝이 예리한 물건으로 터치패널을 누르지 마십시오.
○설치, 배선작업 및보수ㆍ점검은 전문지식이 있는 사람이 실시해 주십시오.
○리튬전지를 사용한 AnyTouch를사용하는 경우, 리튬전지가 리튬 및유기용매 등가연성 물질을 내장하고 있으므로 취
급을 잘못하면 발열, 파열, 발화 등으로 부상을 당하거나 화재로 이어질 우려가 있습니다. 본서 및관련 매뉴얼에 기재된
주의사항을 준수하여 바르게 취급해 주십시오.
○스위치 분해능이 아날로그 저항막 방식인 AnyTouch를사용하는 경우, 스크린을 동시에 2점이상 누르지 마십시오. 동시
에2점이상을 누른 경우, 누른 점의 중심에 스위치가 있으면 그스위치가 작동하는 경우가 있습니다.
○운전중의 설정변경, 강제출력, 기동, 정지 등의 조작은 충분히 안전을 확인한 후에 실시해 주십시오. 조작실수로 인해 기
기가 작동하여 기계 파손 및고장의 우려가 있습니다.
○AnyTouch가고장나서 인명과 관련되거나 중대한 손실 발생이 예상되는 설비에 적용하는 경우에는 반드시 안전장치를
설치해 주십시오.
○AnyTouch를폐기할 때는 산업폐기물로 취급해 주십시오.
○AnyTouch에접촉하기 전에는 접지된 금속 등에 접촉하여 인체 등에 대전된 정전기를 방전시켜 주십시오. 과대한 정전
기는 오작동, 고장의 원인이 됩니다.
UL/c-UL 승인
V706 Plus 시리즈는 UL/cUL 승인 제품입니다. (파일 번호: E256956 (UL60950-1))
이시리즈는 다음 표준을 준수합니다.
- UL60950-1 정보 기술 장비 – 안전 – 제1부: 일반 요구사항
- CSA-C22.2 제60950-1호정보 기술 장비 – 안전 – 제1부