RELAY 1 RELAY 2 RELAY 3 RELAY 4
FUSE
POWER
TIMER
Timer Select Button –Used to select timer mode
Erase Button –Press and hold to erase all pairings, see
advanced operation for individual erase
Signal Test mode –Press to enter signal test mode
Sync/Pair Button –Press once to auto sync. See
Advanced operation for other pairing options.
Momentary/Latching Jumper Links –It is possible to set
the relay switches on the ELITE receiver to either momentary
or latching operation.
Latching (link fitted) - One press for on, one press for off.
Momentary (link removed) - On while button is held only.
To set a relay switch to either momentary/latching choose the
associated link cap.
NOTE:
If link is changed, power cycle
the receiver (turn off/on) otherwise it will stay in the
same mode it was previously set in.
230Vac power
input
Power input fuse –should be 500mA
Relay switch terminals:
Common
Normally Open
Normally Closed
RELAY 1
RELAY 2
RELAY 3
RELAY 4
SYNC
TEST
ERASE
Status LEDs–Flash when
signals are sent/received
L N E
8
7
6
5
4
3
2
1
Mag sync –Touch a
magnet to the plastic
case in the cross
hatched area to
replicate the sync
button on board
without opening the
case
0Vdc
12-32Vdc
NO COM NC NO COM NC NO COM NC NO COM NC
CONNECT EITHER
230Vac OR 12-32Vdc
NEVER BOTH