10 DIGISTEEL III /DIGIPULS III 420-520
List of accessible parameters in COnFIG menu
Left display Left display Left
display
Left
display Left display
GrE On -;OFF – Aut Aut
Configuration of the Water Cooling Unit. 3 possibles states :
-On : Forced on, watercooler is always activated
-OFF : Forced off, watercooler is always desactivated
-Aut : Automatic mode, Watercooler works when according need
ScU nc – no - OFF OFF
Security of water cooling. 3 possible states :
-nc : Normally closed,
-no : Normally open,
-OFF : Desactivate
Unit US – CE CE Unit displayed for wire speed and thickness:
- US : inch unit
- CE : meter unit
CPt OFF– 0,01 – 1,00 0,01 s 0,30 Trigger holding time in order to call program (Only in 4T welding mode).
Can be use only for welding program from 50 to 99.
LAn Fr,dE,En,It,ES,PO,
,nL,SU,Pt,rO,dA,
nO,Fi,Sh,CS,Hu En
Choose language displayed only if RC-JOB or P500 wire feeder are connected
French(Fr)-German(DE)- English(En)-Italian(It)- Spanish(ES)-Polish(PO)- Dutch(nL)-
Swedish(SU)-Portuguese(Pt)- Romanian(RO)- Danish(DA)- Norwegian(NO)- Finnish(Fi)-
Slovak(Sk)- Czech(CS)- Hungarian(Hu)
PGM no – yES no
ctivate / desactivate program management mode
PGA OFF – ;000 – 020 %1% OFF Use to setup available adjustement range of the following parameters: wire speed, arc
voltage, arc dynamics, pulse fine-setting. Use only when program management is
activated and programs are locked.
CAL OFF – on OFF Calibration of torch & ground harness
AdJ Loc –- rC Loc Select adjustement Wire speed and arc voltage :
- Loc : Local on the power source
- rC : remote Control or torch potentiometer
L 0 – 50 1 uH 14 Cable choke setting / display
r 0– 50 18 Cable resistor setting / display
SoF no – yES no Software update mode.
FAC no – yES no Factory settings reset. Pressing YeS
will cause a reset of the parameters to factory
defaults when exit SETUP menu.
List of accessible parameters in CYCLE menu
Left display Left display Left
display
Left
display Left display
tPt 00.5 – 10.0 0,1s 0,5Spot time.
In Spot mode and in Manual mode, the Hot Start, Downslope and sequencer
settings cannot be changed
PrG 00.0 – 10.0 0,1s 0,5Pre-gas time
tHS OFF – 00.1 – 10.0 0,1s 0,1Hot start time
IHS -- 70 – 70 1 % 30 Hot start current (wire speed). X%
the welding current
UHS -- 70 – 70 1 % 0 Hot start voltage X%
the arc voltage
dYn --10 + 10
--20 – 20 1% 0 Fine setting in short arc
rFP --10 + 10
--20 + 20 1% 0 Fine setting in pulse
dyA 00 – 100 1 50
rc striking dynamics at electrode
tSE OFF – 0.01 – 2.50 0,01 s OFF Sequencer time (Sequencer, only in synergic mode)
ISE ---90 + 90 1 % 30 Sequencer current level. X%
the welding current
dSt OFF – 00.1 – 05.0 0,1s OFF Down-slope time
DdSI -- 70 – 00.0 1% -- 30 Down-slope current (wire speed). X%
the welding current
dSU -- 70 – 70 1 % 0 Down-slope voltage. X%
the arc voltage
Pr_ 0.00 – 0.20 0,01 s 0,05
nti-stick time
PrS Nno – yES no Pr-Spray activation
PoG 00.0 – 10.0 0,05 s 0,05 Post-gas time
NOTE : The DIGISTEEL III 420-520 / DIGIPULS III 420-520 allows to lock program menu. This function is available on program screen with the parameter
cod. The locking key entered has to be written in order to desactivate the function lock.
3.3.4. Program call with trigger
This function allows to chain from 2 to 10 programs. This function is available in 4T welding mode only and
program management mode has to be activated
Program chaining :
The function program call works with programs from P50 to P99 by ten.
P50P59 ; P60P69 ; P70P79 ; P80P89 ; P90P99
Selec first program with which you want to begin your chain. Then during welding, each time you will push trigger, program will change.
To chain less than ten programs, in the program following end of loop desired put a different parameter (As synergy or welding cycle).