Safety Technology International STI-7522 User manual

MAGNET
6297520 GASKET
(1) PROVIDED
04874
MOUNTING
PLATE
SCREW #8-32 x 1/2 in.
(4) PROVIDED
AMS-10S MAGNETIC CONTACT
SWITCH WITH 24 in. WIRE LEADS
19013 SCREW
#10 x 1 1/2 in.
(4) PROVIDED
06298 MOUNTING TABS
(4) PROVIDED
19033 ANCHOR
(4) PROVIDED
STI-7523 THUMB LOCK
STI-7522 KEY LOCK AVAILABLE
STOP
STOP
EMERGENCYUSEONLY
INSTALLATI N F STI-7522 & STI-7523 PR TECTIVE CABINET
Safety Technology International, Inc. • 2306 Airport Rd. • Waterford, Michigan 48327-1209 • 800-888-4784 • Fax: 248-673-1246 • Web: www.sti-usa.com • Email: [email protected]
ALARM MOUNTING PLATE
CABINET
WIRE ACCESS HOLE
ROUTE THE 2 SWITCH WIRES
THROUGH THE HOLE AS SHOWN
VIEW A
OPTIONAL MOUNTING
HOLES (4)
A
9 VOLT ALKALINE BATTERY
ALARM COVER
19016 TAMPERPROOF TOOL
19032 KEY (2) PROVIDED
19011 SCREW - TAMPERPROOF
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
ALARM MOUNTING PLATE
06202 BACKPLATE
STOP
EMERGENCYUSEONLY
STOP
19018 ANCHOR (2) PROVIDED
T
INSTALLATI N F STI-7523 ENCL SURE
1. Insert the (4) mounting tabs fully into backbox mounting tab
slots. Use rubber mallet if necessary.
2. After selecting a suitable location, place enclosure in closed
position, against the wall. ark and drill (4) 1/4 in. diameter
holes. Insert the (4) 19033 anchors. Close and lock enclosure.
3. Place enclosure in position making sure the (2) switch wires
are not pinched between the wall and enclosure. Drive in the
(4) screws. Enclosure is now secure.
1. Place the alarm mounting plate on the
top center of enclosure. Select at least
two of the four optional mounting
holes. ark and drill 3/16 in. holes and
install the 19018 anchors.
2. Fish the magnetic switch wires through
the alarm mounting plate and the siren
backplate (View A). Next, drive the two
alarm mounting screws into the
previous installed anchors.
3. Install the two magnetic switch wires
following the terminal switch diagram
(View B).
4. Install the alarm cover using the (2)
tamperproof screws and provided tool.
*1/4” Diameter
INSTALLATI N F ALARM ASSEMBLY
3.125 in.(79mm)
10.875 in.
(276mm)
8.875 in.(225mm)
STOP
EMERGENCY USE ONLY
P
FRONT VIEW
TOP VIEW
16.00 in.
(406mm)
M
*
SWITCH SETTINGS
Volume - High (105 dB) at 1 ft. ON*
Volume - Low (95 dB) at 1 ft. OFF
Duration - 30 Second Alarm OFF OFF
Duration - 180 Second Alarm OFF ON
Duration - Continuous Alarm ON* OFF*
Duration - Annunciator ode ON ON
Trip - Immediate OFF*
Trip - 15 Second Delay ON
Arming - Immediate ON*
Arming - 15 Second Delay OFF
FEATURE JP2 JP3 JP4 JP5 JP7
*Factory Settings
Note: Slide black lever to desired ON/OFF position as labeled on circuit board.
Printed in USA
Safety Technology International, Inc.
2306 Airport Road • Waterford, ichigan 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784
Fax: 248-673-1246 • www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com
CIRCUIT B ARD SET-UP
N
Mark and drill 3/16 in.
Nex
JP5
JP2
JP4
JP3
JP7
ALARM VOLUME SWITCH
TRIP DELAY SWITCH
ARMING SWITCH
(FACTORY DEFAULT SETTINGS)
(ON)
(ON)
(OFF)
(OFF)
(OFF)
ALARM CIRCUIT BOARD SET-UP
ALARM
DURATION
SWITCH
TERMINAL BLOCK
D
Inst. Sht. 7523, JAN2010
B
FROM MAGNETIC
CONTACT SWITCH
N
TERMINAL STRIP
NC COM NO GD V+RS1 RS2 KEYSW
VIEW B
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
KEY SWITCH
TERMINALS
TERMINAL BLOCK WIRING CONNECTIONS
MAGNETIC CONTACT
REED SWITCH
JUMPER
M
Electronic warranty form at www.sti-usa.com/wc14

This manual suits for next models

1

Popular Protection Device manuals by other brands

Granberg 881 user manual

Granberg

Granberg 881 user manual

Panduit DAP3 Series installation instructions

Panduit

Panduit DAP3 Series installation instructions

ABB REL670 2.2 IEC Applications manual

ABB

ABB REL670 2.2 IEC Applications manual

Merlin PowerGuard PRO User's installation guide

Merlin

Merlin PowerGuard PRO User's installation guide

3M PELTOR Optime MT155H530A 380 manual

3M

3M PELTOR Optime MT155H530A 380 manual

CADDX xGenConnect Installation and programming guide

CADDX

CADDX xGenConnect Installation and programming guide

ABB Relion 670 series Operation manual

ABB

ABB Relion 670 series Operation manual

Microelettrica Scientifica MC2-30M Operation manual

Microelettrica Scientifica

Microelettrica Scientifica MC2-30M Operation manual

Trinity SS180 TMA 9182 Assembly manual

Trinity

Trinity SS180 TMA 9182 Assembly manual

Arcteq AQ-M257 instruction manual

Arcteq

Arcteq AQ-M257 instruction manual

LEADING EDGE SAFETY R2000 instruction manual

LEADING EDGE SAFETY

LEADING EDGE SAFETY R2000 instruction manual

Allen-Bradley TLS1-GD2 installation instructions

Allen-Bradley

Allen-Bradley TLS1-GD2 installation instructions

ABB RED615 ANSI Product guide

ABB

ABB RED615 ANSI Product guide

American Innovations SurgeProtect Kit Quick reference guide

American Innovations

American Innovations SurgeProtect Kit Quick reference guide

ABB Relion 670 series Product guide

ABB

ABB Relion 670 series Product guide

Segen Solar ACDB-250A-500A-2-1-1 installation manual

Segen Solar

Segen Solar ACDB-250A-500A-2-1-1 installation manual

ABB RELION REL670 Product guide

ABB

ABB RELION REL670 Product guide

Guardian 01600 instruction manual

Guardian

Guardian 01600 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.