Salus ST100ZB User manual

SMC-GM-CWSG-M5-2019.11v1_2019-11-24
Connected Wireless System Guide
Module 5 – Connected Fan Coil Controls

Section Page
1 Introduction
Using this Manual...................................................................................................1-1
System Overview ...................................................................................................1-2
2 Keypad & Display – Fan Coil Controls
Keypad .............................................................................................................2-1
Display .............................................................................................................2-1
3 ST100ZB Line Power Fan Coil Thermostat
Included Parts / Tools Required......................................................................................3-1
Remove Thermostat (if replacing existing thermostat)................................................................3-2
Thermostat Installation .............................................................................................3-4
4 ST101ZB Low Voltage Fan Coil Thermostat
Included Parts / Tools Required......................................................................................4-1
Remove Thermostat (if replacing existing thermostat)................................................................4-2
Thermostat Installation .............................................................................................4-4
5 SC102ZB Wireless Fan Coil Controller / ST103ZB Wireless Fan Coil Remote
Included Parts / Tools Required......................................................................................5-1
Remove Thermostat (if replacing existing thermostat)................................................................5-2
SC102ZB Fan Coil Controller Installation .............................................................................5-3
Optional External Antenna (Sold Separately) .........................................................................5-5
ST103ZB Wireless Fan Coil Remote Installation .......................................................................5-6
6 Pairing Instructions – Fan Coil Controls
Pairing Instructions .................................................................................................6-1
Joining the SG888ZB Gateway Network..............................................................................6-1
Linking SC102ZB Fan Coil Controller to ST103ZB Remote .............................................................6-3
Conguring Fan Coil Controls with SALUS Smart Home Application...................................................6-4
7 Device Configuration – Fan Coil Controls
Settings Button Operation ..........................................................................................7-1
Special Function Codes .............................................................................................7-4
8 Operation
Operating Modes ...................................................................................................8-1
Programmable Thermostat (Standalone or Local Mode Only) .........................................................8-2
Set Point Override ..................................................................................................8-2
Heating/Cooling Modes.............................................................................................8-2
Fan Modes..........................................................................................................8-3
Accessory Function .................................................................................................8-4
AWAY Mode ........................................................................................................8-5
9 Device Troubleshooting
Troubleshooting ....................................................................................................9-1
Appendix A – Parameter List
Parameter List ......................................................................................................A-1
SALUS Connected Wireless System Guide
Contents: Connected Fan Coil Controls
Module 5
i

This page intentionally left blank.

1-1
Using this Manual
For the latest Instructions go to: WWW.SALUSINC.COM
To cover all SALUS Wireless Products without requiring customers to download unnecessary
documentation, the Wireless System Guide has been divided into 5 Modules. Module 1 is required for
all connected systems since it covers installation of the SG888ZB Gateway and the SALUS Smart Home
application. The remaining modules are specic to a particular group of controls.
Below is a description of several icons used to direct the reader’s attention.
Special Attention Boxes
This manual uses special attention icons to alert the reader of important safety concerns, information
important to reliable operation of the controls or helpful installation/setup information.
Safety:
Indicates a condition which may cause severe personal
injury, death or major property damage
Important Information:
Indicates information which requires special attention
for correct operation of the control
Your Benet:
Indicates helpful installation or setup information
Module 5 – Connected Fan Coil Controls
Introduction
Section 1

1-2
System Overview
SALUS connected Fan Coil control systems use Zigbee-based communications protocol to provide a
universal language for smart components to work together seamlessly and securely with an internet
connection.
Module 4 – Wireless HVAC Thermostats
Introduction
Section 1
By connecting the SG888ZB Gateway to your home network, the system is connected to the worldwide
web. Monitor or adjust your Fan Coil system from anywhere via the SALUS Smart Home application from
a smart device or computer. If the connection to the internet is lost, the system continues to function
with the settings selected.

2-1
Keypad
Module 5 – Connected Fan Coil Controls
Keypad & Display – Fan Coil Controls
Section 2
Table 2.1: Keypad Functions
MODE Heat, Cool, Auto, Off selection Increase Value
Fan On/Auto, Low Speed, Medium
Speed, or High Speed Decrease Value
Enter/Exit Settings mode
SELECT Confirm/Change Display Mode/Acti-
vate Permanent Hold
Display

2-2
Module 5 – Connected Fan Coil Controls
Keypad & Display – Fan Coil Controls
Section 2
Table 2.2: Display Icons
Heat/Cool/Off Modes
Cooling (Animated when cooling is on) Heating (Animated when heat is on)
Auto Heat/Cool Changeover Off
Fan Modes
ON – Indicates Constant Fan Enabled
3 Dots – High Speed
AUTO – Automatic Fan Speed
– Constant Fan Disabled
1 Dot – Low Speed
AUTO – Automatic Fan Speed
Fixed Fan Speed – Low Fixed Fan Speed – Medium Fixed Fan Speed – High
Wireless/Internet Indications
Device connected to local network Device connected to SALUS Smart Home Service
Test/Key Lock/Battery/Filter
Test Mode (Special Code 22) Keys Locked Mode
Battery Low (ST103 Wireless Remote Only) Change Filter (Timer expired)
Accessory Output On (Humidifier, Dehumidifier, ERV or HRV)
Internal/External Temperature Sensor
External Sensor Indication (wired or wireless) Internal Sensor Indication (Only visible in TEST Mode)
Schedule Indications
Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7)
Schedule Interval (1-6) - Specifies time interval
of scheduled temperature changes
Schedule Indicator – When shown, the Thermostat is
following a schedule
Setback Indicator – Setback input is activated AWAY State Indicator – Displayed when the Fan Coil
Thermostat is set to AWAY, using setback temperatures
Multifunction Temperature Indication
Pipe temperature reading shown Setpoint temperature reading shown

3-1
Included Parts
#1 Phillips or athead screwdriver Smartphone or digital camera
– (optional for wiring reference photos)
Small screwdriver (optional for
existing thermostat terminals)
Wiring Labels
Mounting
Screws
Thermostat with
Wiring Mount
Installation/Quick Start
Guide (English & French)
Tools Required
Module 5 – Connected Fan Coil Controls
ST100ZB Line Power Fan Coil Thermostat
Section 3
Be sure that all parts listed are included and available before starting installation.

3-2
Step 1. Review and record the existing thermostat wiring conguraiton:
- Remove thermostat from wall plate to expose wiring terminals
- Take a photograph or note the wire colors and connections (see wiring reference table below)
- Attach wire labels to each of the wires
Remove Thermostat (if replacing existing thermostat)
Table 3.1: Wire Designation Record
Terminal
Designation Wire Color Function
4-Pipe System 2-Pipe System
LBlack 120/240 VAC Line Power 120/240 VAC Line Power
NWhite 120/240 Neutral 120/240 Neutral
WY Red Heating Valve Actuator Heating/Cooling Valve Actuator
YA Blue Cooling Valve Actuator Auxiliary Heat
Gl Brown Fan Signal – Low Speed Fan Signal – Low Speed
Gm Orange Fan Signal – Medium Speed Fan Signal – Medium Speed
Gh Yellow Fan Signal – High Speed Fan Signal – High Speed
Ac Accessory Contact Accessory Contact
Ac Accessory Contact Accessory Contact
Tp Supply Pipe Temperature Sensor Supply Pipe Temperature Sensor
Tx External Temperature Sensor External Temperature Sensor
Ts Temperature Setback Temperature Setback
Tc Tp/Tx/Ts Common Tp/Tx/Ts Common
Before removing the existing thermostat, turn
o power to the fan coil system.
Module 5 – Connected Fan Coil Controls
ST100ZB Line Power Fan Coil Thermostat
Section 3
Step 2. Label each wire when disconnecting them from thermostat terminals and remove the thermostat
mounting plate.
Paint the mounting surface, if desired, before mounting the new thermostat back plate to
ensure complete wall coverage.

3-3
Step 1. Install the Wiring Mount in the desired location using the junction box screws provided, making
sure the wires go through the center opening. An optional wall plate (sold separately) is available for
mounting to other junction box congurations.
Step 2. Connect the wiring to the ST100ZB Back Plate. Use the chart below to identify the desired
conguration. Schematic diagrams for 4-Pipe, 2-Pipe and 2-Pipe Applications are provided on the
following page.
Module 5 – Connected Fan Coil Controls
ST100ZB Line Power Fan Coil Thermostat
Section 3
Thermostat Installation
Table 3.2: Wiring Configuration Checklist
Configuration L N WY YA Gl Gm Gh Ac Ac Tp Tx Ts Tc*
2-Pipe Heat Only W o o o o o o
2-Pipe Cool Only Y o o o o o o
2-Pipe Heat/Cool
Manual Changeover W/Y o o o o o o
2-Pipe Heat/Cool
Seasonal Changeover W/Y o o o o
2-Pipe Heat/Cool
w/Auxiliary Heat W/Y A o o o o
4-Pipe Heat/Cool w/Manual
or Auto Changeover W Y o o o o o o
=Required / o=Optional / W=Heat Valve Actuator / Y=Cool Valve Actuator / A=Auxiliary Heat
* If using more than one (Tp/Tx/Ts) terminal, it may be necessary to splice Tc.
Horizontal 2” x 4”
Junction Box
Vertical 2” x 4” Junction Box
(wall plate sold separately)
4” x 4” Junction Box
(wall plate sold separately)

3-4
Module 5 – Connected Fan Coil Controls
ST100ZB Line Power Fan Coil Thermostat
Section 3
ST100ZB
2-Pipe Application
ST100ZB
2-Pipe Auxiliary
Heat Application
ST100ZB
4-Pipe Application
ST100ZB
Internal Block
Diagram

3-5
Module 5 – Connected Fan Coil Controls
ST100ZB Line Power Fan Coil Thermostat
Section 3
Step 3. Attach Thermostat to the Wiring Mount
by aligning the connector pins.
Make sure the connector pins are not bent and that the Thermostat is fully seated on the
wiring mount.
Remove any unused, pre-wired leads or add wire nut cap to isolate line voltage.
Step 4. Turn on power to the fan coil system
and thermostat.

4-1
Module 5 – Connected Fan Coil Controls
ST101ZB Low Voltage Fan Coil Thermostat
Section 4
Included Parts
#1 Phillips or athead screwdriver 3/16” drill bit (optional) Power Drill (optional)
Wiring Labels
Mounting
Screws
Thermostat with
Wiring Mount
Installation/Quick Start
Guide (English & French)
Tools Required
Be sure that all parts listed are included and available before starting installation.
Smartphone or digital camera
– (optional for wiring reference photos)
Small screwdriver (optional for
existing thermostat terminals)

4-2
Module 5 – Connected Fan Coil Controls
ST101ZB Low Voltage Fan Coil Thermostat
Section 4
Step 1. Review and record the existing thermostat wiring conguraiton:
- Remove thermostat from wall plate to expose wiring terminals
- Take a photograph or note the wire colors and connections (see wiring reference table below)
- Attach wire labels to each of the wires
Remove Thermostat (if replacing existing thermostat)
Table 4.1: Wire Designation Record
Terminal
Designation Wire Color Function
4-Pipe System 2-Pipe System
L24 VAC Input 24 VAC Input
C24 VAC Common 24 VAC Common
WY Heating Valve Actuator Heating/Cooling Valve Actuator
YA Cooling Valve Actuator Auxiliary Heat
Gl Fan Signal – Low Speed Fan Signal – Low Speed
Gm Fan Signal – Medium Speed Fan Signal – Medium Speed
Gh Fan Signal – High Speed Fan Signal – High Speed
Ac Accessory Contact Accessory Contact
Ac Accessory Contact Accessory Contact
Tp Supply Pipe Temperature Sensor Supply Pipe Temperature Sensor
Tx External Temperature Sensor External Temperature Sensor
Ts Temperature Setback Temperature Setback
Tc Tp/Tx/Ts Common Tp/Tx/Ts Common
Before removing the existing thermostat, turn
o power to the fan coil system.
Step 2. Label each wire when
disconnecting them from
thermostat terminals and remove
the thermostat mounting plate.
Paint the mounting
surface, if desired, before mounting
the new thermostat back plate to
ensure complete wall coverage.

4-3
Module 5 – Connected Fan Coil Controls
ST101ZB Low Voltage Fan Coil Thermostat
Section 4
Step 1. Install the Wiring Mount in the desired location using the junction box screws provided, making
sure the wires go through the center opening. An optional wall plate (sold separately) is available for
mounting to other junction box congurations.
Step 2. Connect the wiring to the ST101ZB Back Plate. Use the chart below to identify the desired
conguration. Schematic diagrams for 4-Pipe, 2-Pipe and 2-Pipe Applications are provided on the
following page.
Thermostat Installation
Table 3.2: Wiring Configuration Checklist
Configuration R C WY YA Gl Gm Gh Ac Ac Tp Tx Ts Tc*
2-Pipe Heat Only W o o o o o o
2-Pipe Cool Only Y o o o o o o
2-Pipe Heat/Cool
Manual Changeover W/Y o o o o o o
2-Pipe Heat/Cool
Seasonal Changeover W/Y o o o o
2-Pipe Heat/Cool
w/Auxiliary Heat W/Y A o o o o
4-Pipe Heat/Cool w/Manual
or Auto Changeover W Y o o o o o o
=Required / o=Optional / W=Heat Valve Actuator / Y=Cool Valve Actuator / A=Auxiliary Heat
* If using more than one (Tp/Tx/Ts) terminal, it may be necessary to splice Tc.
No Box or Horizontal
2” x 4” Junction Box
Vertical 2” x 4” Junction Box
(wall plate sold separately)
4” x 4” Junction Box
(wall plate sold separately)

4-4
Module 5 – Connected Fan Coil Controls
ST101ZB Low Voltage Fan Coil Thermostat
Section 4
ST101ZB
2-Pipe Application
ST101ZB
2-Pipe Auxiliary
Heat Application
ST101ZB
Internal Block
Diagram
ST101ZB
4-Pipe Application

4-5
Module 5 – Connected Fan Coil Controls
ST101ZB Low Voltage Fan Coil Thermostat
Section 4
Step 3. Attach Thermostat to the Wiring Mount
by aligning the connector pins.
Make sure the connector pins are not bent and that the Thermostat is fully seated on the
wiring mount.
Step 4. Turn on power to the fan coil system
and thermostat.

5-1
Module 5 – Connected Fan Coil Controls
SC102ZB Wireless Fan Coil Controller /
ST103ZB Wireless Fan Coil Remote
Section 5
Included Parts
#1 Phillips or athead screwdriver
(required)
3/16” drill bit (optional) Power Drill (optional)
Wiring Labels Mounting
Screws
SC102ZB Wireless Fan Coil
Controller with Wiring Mount
Installation/Quick Start
Guide (English & French)
Tools Required
Be sure that all parts listed are included and available before starting installation.
Smartphone or digital camera
(optional - for wiring reference photos)
Small screwdriver (optional )
- for existing thermostat terminals)
Desk Stand Mounting
Screws
ST103ZB Wireless Fan Coil Remote with
Batteries and Wall Mount
Installation/Quick Start
Guide (English & French)

5-2
Module 5 – Connected Fan Coil Controls
SC102ZB Wireless Fan Coil Controller /
ST103ZB Wireless Fan Coil Remote
Section 5
Step 1. Review and record the existing thermostat wiring conguraiton:
- Remove thermostat from wall plate to expose wiring terminals
- Take a photograph or note the wire colors and connections (see wiring reference table below)
Remove Thermostat (if replacing existing thermostat)
Table 5.1: Wire Designation Record
Terminal
Designation Wire Color Function
4-Pipe System 2-Pipe System
R24 VAC Input 24 VAC Input
C24 VAC Common 24 VAC Common
WY Heating Valve Actuator Heating/Cooling Valve Actuator
YA Cooling Valve Actuator Auxiliary Heat
Gl Fan Signal – Low Speed Fan Signal – Low Speed
Gm Fan Signal – Medium Speed Fan Signal – Medium Speed
Gh Fan Signal – High Speed Fan Signal – High Speed
Ac Accessory Contact Accessory Contact
Ac Accessory Contact Accessory Contact
Tp Supply Pipe Temperature Sensor Supply Pipe Temperature Sensor
Tx External Temperature Sensor External Temperature Sensor
Ts Temperature Setback Temperature Setback
Tc Tp/Tx/Ts Common Tp/Tx/Ts Common
Before removing the existing thermostat, turn
o power to the fan coil system.
Step 2. Label each wire when
disconnecting them from
thermostat terminals and remove
the thermostat mounting plate.
Paint the mounting
surface, if desired, before mounting
the new thermostat back plate to
ensure complete wall coverage.

5-3
Module 5 – Connected Fan Coil Controls
SC102ZB Wireless Fan Coil Controller /
ST103ZB Wireless Fan Coil Remote
Section 5
Step 1. Install the Wiring Mount in the desired location using the junction box screws provided, making
sure the wires go through the center opening. An optional wall plate (sold separately) is available for
mounting to other junction box congurations.
Step 2. Connect the wiring to the SC102ZB Back Plate. Use the chart below to identify the desired
conguration. Schematic diagrams for 4-Pipe, 2-Pipe and 2-Pipe Applications are provided on the
following page.
SC102ZB Fan Coil Controller Installation
Table 5.2: Wiring Configuration Checklist
Configuration R C WY YA Gl Gm Gh Ac Ac Tp Tx Ts Tc*
2-Pipe Heat Only W o o o o o o
2-Pipe Cool Only Y o o o o o o
2-Pipe Heat/Cool
Manual Changeover W/Y o o o o o o
2-Pipe Heat/Cool
Seasonal Changeover W/Y o o o o
2-Pipe Heat/Cool
w/Auxiliary Heat W/Y A o o o o
4-Pipe Heat/Cool w/Manual
or Auto Changeover W Y o o o o o o
=Required / o=Optional / W=Heat Valve Actuator / Y=Cool Valve Actuator / A=Auxiliary Heat
* If using more than one (Tp/Tx/Ts) terminal, it may be necessary to splice Tc.
No Box or Horizontal
2” x 4” Junction Box
Vertical 2” x 4” Junction Box
(wall plate sold separately)
4” x 4” Junction Box
(wall plate sold separately)
This manual suits for next models
3
Table of contents
Other Salus Microphone System manuals
Popular Microphone System manuals by other brands

Tranzeo
Tranzeo TR-AP-5a-21 quick start guide

Sennheiser
Sennheiser Esfera SPM8000 instruction manual

ICON
ICON AIRMICSOLO quick start guide

Clear One
Clear One WS840D-M610 quick start guide

IMG STAGE LINE
IMG STAGE LINE TXS-727HSE/B Instruction manuals

Baicells
Baicells ATOM OD15 Installation & configuration guide