Salus VS05 User manual

Dial Thermostat
Models: VS05
INSTALLER / USER MANUAL
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:03 Page 1

02 VS05 Installer Manual
Contents
1 x Installer / User manual VS05
Dial Thermostat
Models: VS05
INSTALLER / USER MANUAL
Fixing screws
Contents
Introduction.
Product Compliance.
Safety information.
Installer Parameters.
Thermostat Installation.
Mounting position and
installation.
System grouping and
communication.
System option 1.
All programmable
thermostats.
Parameter settings.
User interface.
LED indication when
following Group Master.
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:03 Page 2

Product Compliance & Safety Information
We hope you enjoy this product...
VS05 Installer Manual 03
INTRODUCTION
Thank you for purchasing the SALUS room
thermostatVS05. TheVS05 is a 230V dial
thermostat which oers simple temperature
control of your heating system.
SALUS recommends that you use your VS05
with the SALUS KL10 and VS10. TheVS10 can be
used as a group master and connected using
the data cable see page xx.
Product Compliance
This product is CE compliant and meets the
following EC Directives Electro-Magentic
Compatibilty directive 2004/108/EC
Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations
The SALUSVS05 is to be used for room
control of hot water heating systems
Inside the house
Installation
This product must be tted by a competent
person, and installation must comply with the
guidance, standards and regulations applicable
to the city, country or state where the product
is installed. Failure to comply with the
requirements of the relevant guidance,
standards and regulations could lead to injury,
death or prosecution.
Always isolate the AC mains supply
before installing or working on any components
that require 230V AC 50Hz supply.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:03 Page 3

Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains
supply before removing the cover.
230V AC
Emergency
Switch o the voltage to the indivdual thermostat
wiring centre or Complete system.
Installer parameter settings
The SALUSVS05 is equipped
with installer paramter section
this must only be entered
by the installer or comptent
Person. Changing these parameters
Can have a serious eect on
Your heating system.
For the installer
Please enter any parameter
Changes in the installer notes section
04 VS05 Installer Manual
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:03 Page 4

VS05 Installer Manual 05
Installation –Thermostat Mounting
Not to be positioned on an exterior wall.
Mounting position and installation
To ensure trouble free operation and ecient control, the unit is best positioned in a draft free
area and at 130cm from the oor. Do not position the thermostat near any heat source, behind
curtains, direct sunlight or an area of high humidity.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:03 Page 5

06 VS05 Installer Manual
System Overview Grouping and Communication
Power and Switching Cable –
used to power thermostats and drive output
Grouping and Communication cable
While the thermostats can function as standalone , Installing this
Optional inexpensive Communication cable allows the thermostats
to communicate with the SALUSVS10 congured as a group master
through the SALUS KL06 WC( both sold separately).
The VS05 will follow instructions of the VS10 Bringing central
control of features such as Time control, Holiday & Party functions
as well as frost control.TheVS05 can leave or re-enter group control
at the slide of a switch.
VS10 Group master
(sold separately )
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 6

VS05 Installer Manual 07
Introduction
The systems below although not exhaustive show the main options. The maximum number of groups per KL10
wiring centre is two. The group selection communication cable must correspond to the group terminals on the
KL10 WC. Please refer to note xx and the KL10 installation guide.
Group 1 – For Example Down stairs Group 2 – For Example upstairs
SALUS KL10
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 7

08 VS05 Installer Manual
Installation –Thermostat Mounting
1
3
2
60mm
Wall Mounting
For wall mounting, mark and
mount the rear case to the wall.
TheVS05 is suitable for wall boxes
with a centre hole distance of :
Gently remove front housing.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 8

VS05 Installer Manual 09
Installation – Terminal Connections
Understanding your terminal connections
Rear of VS05
Power Terminals 230 Vac
Used for supplying power to the
unit and switched output.
Sensor Terminals
Can be used for external AIR,
Floor sensor when congured
as thermostat. Can also be
used for Cylinder thermostat
when calling for HW.
Communication Terms 12VDC
Two wire twisted pair
can be used for Grouping
Functions between
Programmable, Digital and HW,
Dial and also for Heat/Cool changeover
3
1
2
3 2 1
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 9

10 VS05 Installer Manual
Installation –Thermostat Connections
xxxxxxxxxxxxx
Optional communication
connection 12VBC
xxxxxxxxxxx
LABEL
& TEXT
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 10

VS05 Installer Manual 11
Installation – Terminal Connections
Power Terminals
Sensor Terminals (if applicable)
Communication Terminals
You are ready to secure the rear housing to the wall box
Check that the wiring is completed for:
1
2
3
Please use the screws provided
Ensure the orientation arrow
is pointing upwards.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 11

Installation – parameter setting
12 VS05 Installer Manual
1
2
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 12

Installation – parameter setting
VS05 Installer Manual 13
FUNCTION DESCRIPTION DEFAULT
Valve Exercising
PWM
PROBE
Actuator
Setback
ON
ON
ON
ON
ON
If the installer setting is to enable the valve exercising the dial thermostat will
additionally send 5 minute pulse on actuator once a week, 24 hours- 7 days.
PWM output to drive actuator open/close
Need help
Actuator can be normally closed/normally open.
Subject to installer jumper selection
Need help
12
Parameter setting
Floor sensor temp
(optional)
If you are tting an external
sensor for air/oor sensing
please select temp here. It can
be set from 0-45 and as preset
at 27. Please note the dip
switches (2) need to be set for
Air or Floor.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 13

User Interface
14 VS05 Installer Manual
Slide switch must be in“A”position to follow group master VS10
LED Indication
Temperature Adjustment 5-30 oC
Mode Selection
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 14

LED indication when following Group Master
VS05 Installer Manual 15
Slide switch must be in“A”position to follow group master VS10
If you do not want a VS05 to follow the group master VS10 please select or see page XX
RED Led indicates that power
is going to the unit in normal
operation. The top LED will
illuminate when room
termperature falls below
your required temp.
Green LED means that
the unit is calling for heat.
The group master will be in.
1.
2.
3.
VS10 Group Master Display
For more details on VS10
please refer to VS10 manual
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 15

16 VS05 Installer Manual
LED indication when following Group Master
Slide switch must be in“A”position to follow group master VS10
If you do not want a VS05 to follow the group master VS10 please select or see page XX
To reduce annoyance factor ,no Led is
shown when the Group master is in
reduced temperature/night time mode.
See below
To adjust reduced temperature oset
please refer to page XXXXXX
Amber LED means that
the unit is calling for heat in
Reduced/night time mode.
The group master will show :
1.
2.
VS10 Group Master Display
For more details on VS10
please refer to VS10 manual
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 16

VS05 Installer Manual 17
LED indication when following Group Master
Slide switch must be in“A”position to follow group master VS10
If you do not want a VS05 to follow the group master VS10 please select or see page XX
Blue LED indicates the units is in frost
protection mode. Frost protection
temperature is xedat ???
Green LED means that the
temperature has fallen below the
frost protection level the unit is
calling for heat.
The group master will be in:
1.
2.
VS10 Group Master Display
For more details on VS10
please refer to VS10 manual
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 17

LED indication in Manual mode
18 VS05 Installer Manual
Slide switch “HAND”position to will not follow Group master VS10 and will longer be part of the group.
TheVS05 will work as a standalone thermostat
To return the VS05 to the group (if applicable) move the slide switch to‘A’.
RED Led indicates that power is going to
the unit in normal operation. The top LED
will illuminate when room termperature
falls below your required temp.
Green LED means that
the unit is calling for heat.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 18

LED indication when following group master
VS05 Installer Manual 19
Slide switch “*”position to will not follow group master VS10 and will longer be part of the group.
TheVS05 will be in permanent frost protection.
To return the VS5 to the group (if applicable) move the slide switch to‘A’.
Blue LED indicates the units is in frost
protection mode. Frost protection
Temperature is xed at ??
Green LED means that the
temperature has fallen below the
frost protection level the unit is
calling for heat.
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 19

Spec
20 VS05 Installer Manual
MODEL
TYPE
TEMPERATURE
Scale
Tolerance
Display Range
Set Temperature range
Frost Protection
CONTROL
ENVIRONMENT RATINGS
Operating Temperature
Storage Temperature
Operating Humidity ( non condensed)
Voltage AC
Frequency
POWER SOURCE
AC POWER DETECTION
CONTROL SWITCH AND RATING
Output rating
Type
Loading
Input
AGENCY APPOVED
VS05
Wired dial thermostat designed for 230v ac heating/cooling applications
Celsius
0.5 oc
5.0-30.0 oc
5.0-30.0 oc
5oc
ON-OFF control / PWM control
0 oc to +50 oc
-20 oc to +60 oc
5-95 %RH
230VVAC
47-59 HZ
230Vac +/- 10%,50/60Hz L,N
AC voltage Monitor
5A for SL output
N.O Power relay
Maximum 3A at SL terminal
Commconnection 12VDC
CV
iT600 VS05 Installer - User Manual_Layout 1 06/06/2014 10:04 Page 20
Other manuals for VS05
1
Table of contents
Other Salus Thermostat manuals

Salus
Salus ST880ZB User manual

Salus
Salus ERT30RT User manual

Salus
Salus iT500BM User guide

Salus
Salus QUANTUM SQ610RF User manual

Salus
Salus QUANTUM SQ610RF User manual

Salus
Salus iT500 User manual

Salus
Salus FT100 Owner's manual

Salus
Salus RT100 User manual

Salus
Salus ERT 52 User manual

Salus
Salus VS20 User manual

Salus
Salus HTRP230V User manual

Salus
Salus RT510WBC User manual

Salus
Salus ERT20RF User manual

Salus
Salus QUANTUM SQ610RF User manual

Salus
Salus RT510BC+ User manual

Salus
Salus HTR230 User guide

Salus
Salus 091FLRF User manual

Salus
Salus FC600 User manual

Salus
Salus VS10WRF User manual

Salus
Salus RT500 User manual