Salus RT510RF User manual

Installation Manual
Model: RT510RF

Product compliance .................................................................................................... 3
Safety Information ....................................................................................................... 3
Box content ...................................................................................................................... 3
Introduction ..................................................................................................................... 3
Features ............................................................................................................................... 4
Installation ......................................................................................................................... 5
1. RXRT510 Receiver ................................................................................................ 5
Button Description for RXRT510 Receiver ........................................... 6
2. RT510RF Thermostat ......................................................................................... 6
Power up .................................................................................................................. 6
DIP Switch Settings ............................................................................................ 7
Button Functions .......................................................................................................... 7
LCD Functions ................................................................................................................. 8
Pairing procedure ......................................................................................................... 8
Pair the RT510RF and RXRT510 ........................................................................ 8
Testing procedure .................................................................................................... 9
Installer Mode ................................................................................................................. 10
Operations ......................................................................................................................... 11
Setting the time ........................................................................................................ 11
Programming the RT510RF ................................................................................ 12
Functions ............................................................................................................................ 14
Review the Setpoint temperature ................................................................. 14
Temporary Override ................................................................................................ 14
Permanent Override ............................................................................................... 15
Boost Function ........................................................................................................... 15
a. Boost Function in Normal Mode .......................................................... 16
b. Boost Function in Permanent Override Mode ............................ 16
c. Boost Function in Temporary Override Mode ............................. 17
d. Boost Function in Frost/Holiday Mode ............................................ 18
Frost Function ................................................................................................................. 18
Holiday Function .......................................................................................................... 19
Other Functions ............................................................................................................. 20
Backlight ............................................................................................................................. 20
Battery Status .............................................................................................................. 20
Sleep Mode .................................................................................................................. 20
Reset Function ............................................................................................................ 21
Technical Information ............................................................................................... 21
Warranty ............................................................................................................................. 22
Contents
02 RT510RF Installation Manual

1x RXRT510
Product compliance
This product complies with the essential requirements and other relevant provisions of the following
EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/EU and 2011/65/EU. The full text of the EU Declaration of
Conformity is available at the following internet address: www.saluslegal.com.
Safety Information
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry.
This product must be installed by a competent person and in accordance with all the EU and national regulations.
Always isolate the AC Mains supply before installing or working on any components that
require 230 VAC 50Hz supply.
Box content
2x screws and plugs
1x Thermostat Stand
Quick Guide Installation
2x AA batteries
1x RT510TX
RT510RF Installation Manual 03

The programmable room thermostat RT510RF is both a programmer and a room thermostat. A programmer
allows you to set ‘On’ and ‘Off’ time periods to suit your own lifestyle. A room thermostat works by sensing the
air temperature, switching on the heating when the air temperature falls below the thermostat setting and
switching it off once this set temperature has been reached.
So, a programmable room thermostat lets you choose what times you want the heating to be on, and what
temperature it should reach while it is on.
It will allow you to select different temperatures in your home at different times of the day (and days of the
week) to meet your particular needs.
Turning a programmable room thermostat to a higher setting will not make the room heat up any faster. How
quickly the room heats up depends on the design of the heating system, for example, the size of boiler and
radiators. Neither does the setting affect how quickly the room cools down. Turning a programmable room
thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to find the lowest temperature settings that
you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best
way to do this is to set low temperatures first, say 18°C, and then turn them up by one degree each day until
you are comfortable with the temperatures. You won’t have to adjust the thermostat further. Any adjustments
above these settings will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to
control the whole house. But you can have different temperatures in individual rooms by installing thermostatic
radiator valves (TRVs) on individual radiators.
If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have
TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then
prevent any overheating in other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the
changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the
heating programme, for example,‘Temporary / Permanent Override’or‘Boost’. All these functions are explained
in the following pages of the Instructions Manual.
Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered
by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the
thermostat from working properly.
The RT510RF from SALUS Controls is a stylish and accurate 5/2 or 24h programmable electronic thermostat with
a large, easy to read Liquid Crystal Display (LCD). This programmable thermostat has been specifically designed
to be used for both Volt Free and AC heating applications. This programmable thermostat can replace most
common residential thermostats and is designed to be used with electric, gas or oil heating control systems.
Introduction
04 RT510RF Installation Manual

Unscrew the backplate of the RXRT510 receiver in order to do the wiring connections. After that please
switch the receiver ON.
ON
AUTO
OFF
MANUAL
COMNO L N
COMNO L N
Terminal Description Receiver Terminals
NO
COM
L
N
Switch Terminal
Common Switch Terminal
Mains Live (230VAC)
Mains Neutral
1. RXRT510 Receiver
• 5/2 days or 24h programming flexibility
• Built-in start up programming for quick installation
• Volt free contacts
• Frost protection
• Large, easy to read LCD with blue backlight
• Burner on symbol
• User friendly
• Stylish casing
• Holiday Mode
• Boost Function
NO COM L N
L N
Electrical diagram
Installation
Features
RT510RF Installation Manual 05

Insert the batteries into the thermostat. Please use 2 AA batteries.
Power up
2. RT510RF Thermostat
Button Description for RXRT510 Receiver
Button Function
ON The receiver is enabled, ready for use.
OFF The receiver is disabled, will not function.
AUTO The receiver will switch on and o automatically,
as operated by the thermostat.
MANUAL Providing ON is selected,the receiver will switch
on continuously, overriding the thermostat.
ON
AUTO
OFF
MANUAL
Note: Please make sure to first wire up and turn on the receiver. After that insert the batteries into the
thermostat and follow the installation steps.
After power up, the thermostat is reset. During system reset, all LCD icons are displayed for 2 seconds and the
keys are locked. After that, all keys are unlocked and the thermostat is initialized. Then software version is shown.
The typical reset display is shown below.
The following tables show the default settings of the RT510 thermostat after Power on, or after Reset button is
pressed:
Function Status after Reset
Operation Mode Normal mode
Room Temperature 22.0°C, to be renewed within 5 seconds
°C indicator On
Clock 12:00
AM/PM indicator AM
Program Default factory setting
Setpoint Temperature Default factory setting
Program Number indicator 1
SET indicator Off
PROG indicator Off
Frost Protection indicator Off
Heat indicator Off
Low-Battery Warning indicator Off, to be renewed within 5 seconds
Output Relay Off
Program Weekday (M to F) Weekend (SA to SU)
1 Time: 6:00am Time: 8:00am
Setpoint Temp: 21.0°C Setpoint Temp: 21.0°C
2 Time: 8:00am Time: 10:00am
Setpoint Temp: 14.0°C Setpoint Temp: 19.0°C
3 Time: 12:00pm Time: 12:00pm
Setpoint Temp: 14.0°C Setpoint Temp: 19.0°C
4 Time: 2:00pm Time: 2:00pm
Setpoint Temp: 14.0°C Setpoint Temp: 19.0°C
5 Time: 6:00pm Time: 6:00pm
Setpoint Temp: 21.0°C Setpoint Temp: 21.0°C
6 Time: 10:00pm Time: 10:00pm
Setpoint Temp: 14.0°C Setpoint Temp: 14.0°C
06 RT510RF Installation Manual

DIP Switch Settings
The DIP switches are found on the rear of your thermostat and can be used to change the span (temperature
accuracy) of your thermostat from the default +/-0.5°C to +/-0.25°C and the programmes 5-2 or 24h.
Changing the Span DIP Switch (2) may cause your boiler to operate more frequently. The DIP switches
are located on the back of the thermostat.
24H
5-2
+/-0.25
+/-0.5
ON
12
Key Function
+Hr
SELECT
SELECT
SET
SET
+
+
+
Press for 3 seconds in order to activate Holiday Mode.
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function.
Increase button
Decrease button
Select the clock or programme settings
Press to conrm your settings
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
1. Press once to enter in Test Mode for RT510RF
2. Press for 3 seconds to enter/exit Pairing Mode for RT510RF
Press once to activate Frost Mode
Button Functions
RT510RF Installation Manual 07

Pair the RT510RF and RXRT510
Please make sure that the thermostat and the receiver are paired. In order to do this you can use the Pairing
or the testing procedure. The Testing procedure will allow you to check if the devices are communicating
between them. The Pairing procedure will allow you to set up a communication between them.
Pairing procedure
Note: Turn the receiver off and on again (ON-OFF-ON). The red LED will start flashing.
ON
AUTO
OFF
MANUAL
ON
AUTO
OFF
MANUAL
ON
AUTO
OFF
MANUAL
1Current day of the program
2Current time
3Temperature unit
4AM/PM
5Frost Mode ON
6Holiday Mode ON
7Temporary/Permanent Override
8Heating Mode ON
9Low battery
10 Boost Mode ON
11 Current temperature
12 Current program
1 2 345 6
7
8
9
10
1112
LCD Functions
08 RT510RF Installation Manual

ON
AUTO
OFF
MANUAL
ON
AUTO
OFF
MANUAL
ON
AUTO
OFF
MANUAL
Note: For ending the pairing process you have two options. You can either wait for 10 min until the pairing
process will automatically end or you can follow the steps below.
ON
AUTO
OFF
MANUAL
2
4
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
1 2
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
TEST / PAIRING
+Hr
SELECT SET
TEST / PAIRING
+Hr
SELECT SET
1 Sec
Testing procedure
1 2
1
3
RT510RF Installation Manual 09

For any advanced settings please access the Installer Mode. Here you will have the possibility to adjust your
frost setpoint, to set the temperature offset and also to choose from two temperature increments. Please follow
the steps below in order to modify the installer parameters.
dxx Function Parameter Description Default
value
d01 Temperature display
increments 0.1 or 0.5°CSelect temperature display
increments 0.5°C
d02 Temperature oset +/-3.0°CCalibrate your thermostat
temperature 0.0°C
d03 Frost setpoint 5.0-17.0°C Set the Frost Point temperature 5.0°C
RESET
+Hr
SELECT SET RESET
+Hr
SELECT SET
3 Sec 3 Sec
3 Sec
RESET
+Hr
SELECT SET
Press and hold all three
buttons together for 3 sec.
Press Set in order to
changed the setting.
RESET
+Hr
SELECT SET
0. 5°C
Press Up/Down to select
the desired value.
1 2
3 4
Installer Mode
10 RT510RF Installation Manual

The RT510RF is configured and adjusted by the use of a minimal number of user controls, and an intuitive
user interface. The Backlight Liquid Crystal Display (LCD) gives a highly visible, easily readable indication of the
programmable thermostat status.
Setting the time
Press the buttons
together for 3 sec.
Press Up or Down to
select the hour format.
1 2
RESET
+Hr
SELECT SET
3 Sec3 Sec
RESET
+Hr
SELECT SET
Press Select and after that Up
or Down to set the minutes.
Continue with the same steps for
setting the Day. Press Set to save
your options and return to the
main Screen.
5 6
Press Up or Down to set the hour.
4
Press Select to confirm.
3
RESET
+Hr
SELECT SET RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
Operations
RT510RF Installation Manual 11

Programming the RT510RF
You can create personalized programmes for your thermostat. You have the option to choose between a 5-2
days programme or a daily one by using the DIP Switches.
5-2 Days Programme
RT510RF
Weekdays
6 sets of time/channel
Weekends
6 sets of time/channel
Total: 12 settings/week
24h Programme
24h
6 sets of time/channel
Total: 42 settings/week
Press Up or Down to select Weekday
Weekend or the Day for which you
want to create the program
Press Set to change your programmes.
RESET
+Hr
SELECT SET RESET
+Hr
SELECT SET
2
1
Press Up/Down to set the hour.Press Select to confirm your option.
RESET
+Hr
SELECT SET
4
RESET
+Hr
SELECT SET
3
12 RT510RF Installation Manual

Repeat the steps above for programs 2-6. After you have done all the changes, please press SET to
confirm all your choices and to return to the Main Screen.
Note: Don’t forget to move the DIP Switch to 24h in order to have the individual programme active.
After that please follow the same instructions as for the 5-2 days programme.
Press Select to confirm your option.
RESET
+Hr
SELECT SET
5
Press Up/Down
to set the minutes.
RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
Press Select to confirm your option.
RESET
+Hr
SELECT SET
Press Up/Down to
set the temperature.
6
7 8
RT510RF Installation Manual 13

Functions
Temporary Override
When the temporary override is active, the setpoint temperature will be changed until the next program starts.
Review the Setpoint temperature
When no button is pressed, your thermostat is showing the actual temperature of the room. To review the
setpoint (desired) temperature follow the steps below:
Actual room temperature Setpoint (desired) temperature
Press Up/Down to review
the setpoint temperature.
Press Up/Down to
set the temperature.
Note: To exit the temporary override procedure, you can wait for 3 seconds until the set temperature
stops flashing or you can press on the SET button once.
1
1
2
2
RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
14 RT510RF Installation Manual

Permanent Override
Press Override in order
to activate the mode.
Press Up or Down to
set the temperature.
Press Set to save
the changes.
The Override sign will appear
on the main screen.
Boost Function
Boost function can be activated when your thermostat is in Normal Mode, in Temporary or Permanent
Override. You cannot set the Boost when in Frost or Holiday Mode. With Boost mode activated you can override,
temporary override or permanently override the thermostat by setting the period of time and also by changing
the Setpoint temperature.
See below the explanations for the Boost Mode settings that are available for each of the modes set on the
thermostat. Please follow the one that suits you needs:
Note: To exit the temporary override procedure, you can wait for 3 seconds until the set temperature
stops flashing or you can press on the SET button once.
RESET
+Hr
SELECT SET RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
RESET
+Hr
SELECT SET
4
1
3
2
4
RT510RF Installation Manual 15

a. Boost Function in Normal Mode
RESET
+Hr
SELECT SET RESET
+Hr
SELECT SET
1
Each press on means an extra
hour added on the Boost function. The
maximum is +9 hours.
+Hr
RESET
+Hr
SELECT SET
1
Press Up or Down to set
the temperature.
RESET
+Hr
SELECT SET
After the temperature is set press Set
to save your options and to return
to Main screen.
4
SET
Note: RT510RF will work in Boost Mode for up to 9 hours, set on the desired temperature. After the Boost
time is over, the thermostat will return to Normal Mode and will follow the schedule created by you.
b. Boost Function in Permanent Override Mode
RESET
+Hr
SELECT SET
Each press on means an extra
hour added on the Boost function. The
maximum is +9 hours.
+Hr
1 2
3 4
12
RESET
+Hr
SELECT SET
1
16 RT510RF Installation Manual

RESET
+Hr
SELECT SET
1
RESET
+Hr
SELECT SET
After the temperature is set press
Set to save your options and to return
to main screen.
Press Up or Down to
set the temperature.
SET
Note: RT510RF will work in Boost Mode for up to 9 hours, set on the desired temperature. After the
Boost time is over, the thermostat will return to the Permanent Override Mode.
c. Boost Function in Temporary Override Mode
RESET
+Hr
SELECT SET
Each press on means an extra
hour added on the Boost function. The
maximum is +9 hours.
+Hr
RESET
+Hr
SELECT SET
1
RESET
+Hr
SELECT SET
1
Press Up or Down to
set the temperature.
After the temperature is set press Set
to save your options and to return to
main screen.
RESET
+Hr
SELECT SET
4
SET
Note: RT510RF will work in Boost Mode for up to 9 hours, set on the desired temperature. After the
Boost time is over, the thermostat will return to Normal Mode, following the schedule set by you.
3 4
12
34
4
RT510RF Installation Manual 17

Note: When Frost/Holiday Mode are activated, the Boost function will be canceled. Also, you cannot
activate the Boost function when the thermostat is set in Frost or Holiday Mode.
d. Boost Function in Frost/Holiday Mode
Frost mode ON Holiday mode ON
RESET
+Hr
SELECT SET
+Hr
SELECT SET
Frost Function
RESET
+Hr
SELECT SET
Frost function allows you to turn the Frost protection ON or OFF. The frost setpoint temperature is preset at 5°C.
You can change the frost setpoint temperature by modifying the Installer Mode parameters, d03. If the room
temperature is lower than the Frost setpoint then the thermostat will automatically change to Frost mode ON.
Follow the steps below for setting up the Frost Mode.
Press the once for turning the
Frost protection ON.
12
12
4
RESET
+Hr
SELECT SET
4
18 RT510RF Installation Manual

Press the once for turning the Frost
protection OFF.
RESET
+Hr
SELECT SET
Press Up/Down to review the
frost setpoint temperature.
RESET
+Hr
SELECT SET
SET 50
Holiday Function
Press the for 3 sec to turn the
Holiday Mode ON.
RESET
+Hr
SELECT SET RESET
+Hr
SELECT SET
SET
1dy
Press Up/Down to set the Holiday
period. *Max 31 days
Holiday function will turn off the relay, blocking your thermostat from sending any call for heat. If room
temperature is lower than the frost setpoint, then Frost Mode will be activated.
Follow the steps below in order to set the Holiday Mode.
3 4
5 6
1 2
RESET
+Hr
SELECT SET
4
RESET
+Hr
SELECT SET
4
3 sec
RT510RF Installation Manual 19

Other Functions
Backlight
The backlight of the RT510RF is switched on automatically whenever any of the keys are pressed. The backlight
will remain illuminated for approximately 5 seconds after the last key press, except if you are changing settings
within the Clock, Programme or Temporary Override modes. In this case, the backlight will remain illuminated
throughout the setting change process. The backlight will not illuminate if the RT510RF battery is low.
Battery Status
The RT510RF checks the battery voltage frequently during normal operation. If the battery voltage is sensed as
being low (this is normally when the battery voltage falls to a level of around 2.6V), the low battery indicator
will be displayed on the screen. You should replace the batteries as soon as possible to prevent any possible
operating problems. When you want to change the batteries your device will use the internal memory to
backup your settings. You have 30 sec to change the batteries before losing your settings.
Sleep Mode
By pressing both the UP and DOWN keys together, the RT510RF will enter SLEEP mode. In this mode, all the
RT510RF functions will be paused to save battery power, with the exception of the clock which will continue
to run in the background.
While in SLEEP mode:
• The LCD display will be blank.
• All output from the Control Unit will be turned off immediately.
Press any key to wake up the RT510RF and cancel SLEEP mode.
RESET
+Hr
SELECT SET
3 sec
3 sec
RESET
+Hr
SELECT SET
1 2
RESET
+Hr
SELECT SET
SET
Press the for 3 sec to turn the
Holiday Mode OFF.
RESET
+Hr
SELECT SET
Note: You can also exit Holiday Mode
by setting the day to zero.
3 4
3 sec
20 RT510RF Installation Manual
Other manuals for RT510RF
3
Table of contents
Other Salus Thermostat manuals

Salus
Salus VS30W User manual

Salus
Salus EP110 User manual

Salus
Salus Quantum SQ610 User manual

Salus
Salus RT310RF User manual

Salus
Salus RT500RF User manual

Salus
Salus RT310i User manual

Salus
Salus ST620WBC User manual

Salus
Salus RT510BC+ User manual

Salus
Salus Optima S User manual

Salus
Salus EP101 User manual
Popular Thermostat manuals by other brands

HomeMatic
HomeMatic HmIP-WTH-1 Installation and operating manual

EBECO
EBECO EB-Therm 30 operating instructions

Vaillant
Vaillant VR 50 Operating and installation instructions

Honeywell Home
Honeywell Home T9 user guide

Thermokon
Thermokon JOY HC AO2DO quick start guide

Network Thermostat
Network Thermostat NetX X7C-WIFI Installation and programming manual