Samsung Smart MBS RRH-P4 User manual

Ver.
2600-00CTEIGAA
4.0
Smart MBS RRH-P4
Installation Manual

Ver.
2600-00CTEIGAA
4.0
COPYRIGHT
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright.
No information contained herein may be copied, translated, transcribed or duplicated for any commercial
purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics
Co., Ltd.
TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective
companies.
This manual should be read and used as a guideline for properly installing and operating the product.
This manual may be changed for the system improvement, standardization and other technical reasons without prior
notice.
If you need updated manuals or have any questions concerning the contents of the manuals, contact our Document
Center at the following address or Web site:
Address: Document Center 3rd Floor Jeong-bo-tong-sin-dong. Dong-Suwon P.O. Box 105, 416, Maetan-3dong
Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea 442-600
Homepage: http://www.samsungdocs.com
©2011~2012 SAMSUNG Electronics Co., Ltd. All rights reserved.

Ver.
Smart MBS RRH-P4 Installation Manual
© SAMSUNG Electronics Co., Ltd. I
2600-00CTEIGAA
4.0
INTRODUCTION
Purpose
This manual describes procedure and method for installing Smart MBS RRH-P4.
Document Content and Organization
This manual consists of 2 Chapters, 6 Annex and Abbreviation as follows:
CHAPTER 1. Before Installation
This chapter introduces safety rules that must be understood for installing RRH-P4 and
describes the configuration of RRH-P4.
CHAPTER 2. Installation of RRH-P4
This chapter describes the procedure to install RRH-P4.
ANNEX A. Sector Antenna Installation
This annex describes sector antenna configurations and its installation requirements.
ANNEX B. Feeder Line Work
This annex describes cautions and allowed radius of curvature when installing feeder line.
ANNEX C. Assembling connector
This annex describes the procedure of assembling connector.
ANNEX D. Cleaning Optic Connector
This annex describes the procedure of cleaning the optic connector and cleaning tool.
ANNEX E. Pressure Terminal Assembly
This annex describes the procedure of assembling the pressure terminal.

Ver.
INTRODUCTION
II © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
ANNEX F. Standard Torque
This annex describes the standard torque when assembling the fixing materials.
ABBREVIATION
Describes the acronyms used in this manual.
Conventions
The following types of paragraphs contain special information that must be carefully read
and thoroughly understood. Such information may or may not be enclosed in a rectangular
box, separating it from the main text, but is always preceded by an icon and/or a bold title.
WARNING
Provides information or instructions that the reader should follow in order to avoid
personal injury or fatality.
CAUTION
Provides information or instructions that the reader should follow in order to avoid
a service failure or damage to the system.
CHECKPOINT
Provides the operator with checkpoints for stable system operation.
NOTE
Indicates additional information as a reference.

Ver.
Smart MBS RRH-P4 Installation Manual/Ver.3.0
© SAMSUNG Electronics Co., Ltd. III
2600-00CTEIGAA
4.0
Revision History
VERSION DATE OF ISSUE REMARKS
4.0 11. 2012. * Added
2.8.5 Hybrid Cable Shield Grounding Connection
* Modified
- Figure 1.3 Cabling Diagram
- Table 1.1 System Cabling
- Table 1.3 Basic Installation Tools
- Figure 2.7 Checking and Assembling Unused Cable
Gland
- Figure 2.15 Connecting RET cable
- Figure 2.16 RET Cable connector
- Table 2.3 RET Cable-Side Connector Pin Map
- Figure 2.24 Connecting Hybrid cable (2)
- Figure 2.26 Connecting Hybrid cable (4)
- 2.8.3 Connecting RRH-P4 Power Cable
- 2.8.4 Connecting RRH-P4 CPRI cable-Power Window
3.0 02. 2012. - Added
2.4 Cable Gland Assembly and Cable Installation
- Modified
Figure 2.25 Connecting Hybrid cable (3)
2.0 09. 2011. - Added caution-‘Managing unused port’
(2.7.2Connecting DU Cabinet side cable)
- Added power cables (AWG8, AWG10), torque
(2.7.3 Connecting RRH-P4 Power Cable)
- Modified RRH-P4 Mounting Bracket configuration
- Modified power SPD configuration.
- Modified power cable, installation method
- Modified Hybrid Cable installation method
- Added CPRI cable connection standard (UADU~RRH-P4)
1.0 06. 2011. First Edition

Ver.
INTRODUCTION
IV © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
This page is intentionally left blank.

Ver.
Smart MBS RRH-P4 Installation Manual
© SAMSUNG Electronics Co., Ltd. V
2600-00CTEIGAA
4.0
SAFETY CONCERNS
The purpose of the Safety Concerns section is to ensure the safety of users and prevent
property damage. Please read this document carefully for proper use.
Symbols
Caution
Indication of a general caution
Restriction
Indication for prohibiting an action for a product
Instruction
Indication for commanding a specifically required action

Ver.
SAFETY CONCERNS
VI © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
Warning
Power and Grounding
Watches, Rings, and Other Metallic Accessories
Do not wear accessories such as watches and rings in order to prevent electrical
shock.
Connecting Ground Cable
In cabling, the connection of cables without the connection to the ground cable
may cause the damage of the equipment or the bodily injury of the worker.
Connect the ground cable first.
Caution When Opening and Closing Power Window Cover
Make sure to turn off the breaker connected to the RRH-P4 power before opening
or closing the power window cover of the RRH-P4.
If you open or close the power window cover when the breaker is turned on, it
may cause damage to the system, or cause an electric short circuit resulting in
severe injury.
Installation General
Caution for Laser Beam of Optical Module and Cable
The optical module and cable used in the system emit bright laser beams.
Always handle them with care as there is risk of serious injury if the eyes are
exposed to the laser beam of the optical cable.
Wearing protection gloves and goggles
Make sure to wear protection gloves and goggles to prevent damages from debris
while drilling holes in a wall or ceiling.
WARNING

Ver.
Smart MBS RRH-P4 Installation Manual/Ver.3.0
© SAMSUNG Electronics Co., Ltd. VII
2600-00CTEIGAA
4.0
Caution
Power and Feeder line
Caution for cleaning the Power Supply
While cleaning the power supply device, take caution that the device does not
come in contact with alien bodies that may cause power failure.
Caution for installing the power cable
To maintain cable gland’s rain protection performance, 11.81 in. (300 mm) or
more interval should be kept straight. According to the radius of curvature of the
cable specification should be considered.
Caution for cutting the power cable
Cut power cable after installing power cable to RRH-P4 power terminal taking into
account the radius of curvature according to the cable specifications.
When cutting the cable first, the length difference of cable end can be occurred by
cable curvature and the power terminal may cause contact fault.
Caution When Connecting Optical Cables
Before connecting an optical cable, make sure that there is no dust or foreign
substance on the cross-section of the connector core. If there is any dust or foreign
substance, do not remove it by blowing with your mouth. Remove the dust or
foreign substance by referring to the method of cleaning optic connector.
Caution on Rain-proof Gasket Damage When Installing Window Cover
Be careful so as not to let the rain-proof gasket get damaged (broken or
incorrectly positioned). Check whether the rain-proof gasket is damaged before
closing the power window cover and the optic window cover.
If the rain-proof gasket is damaged, replace the system (RRH-P4) with a new
one.
CAUTION

Ver.
SAFETY CONCERNS
VIII © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
Radius of Curvature of Feeder Line
When installing a feeder line, the radius of curvature of the sections where cables
bent should be larger than the allowed radius of curvature. If the radius of curvature
for the feeder line installation is less than the allowed radius of curvature, it may
affect the performance of the system.
Connection of Feeder Cable Connector
Connecting the feeder cable connector is critical process, so the qualified workers
who finished the related education should perform.
Caution When Connecting RET Cable
Make sure to turn off the breaker connected to the RRH-P4 power of the DU
cabinet before connecting the RET cable between the antenna RET port and the
RRH-P4 RET port.
If you connect or disconnect the RET cable while the breaker is turned on, it may
cause an electric short circuit resulting in damage to the RET function.
Installation General
Caution when losing External Power Cable Support Bracket (‘2.6 Connecting
ground cable’)
External Power Cable Support Bracket and two cable tie (stainless steel) for fixing
cable are enclosed in RRH-P4 package. Be careful not to lose when unpacking
package.
Managing unused port
Finish unused port of UADU by dust-cap, not making the alien substance flowed.
Finishing Cable Insertion Hole
Finishing work is required on cable insertion holes (Cable gland, Conduit and
etc.) to prevent entering of any foreign substance, external air and moisture.
- Unused cable insertion hole: Finish cable insertion hole using fishing materials
such as dust cap, rubber packing and etc.
- Cable-installed insertion hole: After installing cable, finish insertion hole using tape,
compressed sponge, rubber packing, silicon, etc. to prevent empty space.

Ver.
Smart MBS RRH-P4 Installation Manual/Ver.3.0
© SAMSUNG Electronics Co., Ltd. IX
2600-00CTEIGAA
4.0
Caution when assembling the cable gland
Ensure that all parts of the cable gland are assembled in the correct sequence.
Incorrect assembly may result in influx of external air or moisture into the system
and may cause corrosion, system malfunction and/or critical failure of the cooling
system.
Caution when installing the cable in the cable gland
Only one cable of permitted specification (radius) should be installed in the cable
gland.
- Installing a cable of smaller radius than the permitted specification may result in
influx of external air or moisture into the system and may cause corrosion or
system malfunction.
- Installing a cable thicker than the permitted specification or installing two or
more cables in the gland may damage the gland.
Caution when loosen and tighten the Cable Gland Nut
In case of assembling the cable gland and cabling, do not loosen and tighten by
turning the cable gland body or other parts. turning the cable gland body may
cause corrosion and system failure by entering of any external air and moisture.
Checking assembly state of the unused cable gland
All components of the unused cable gland must be secured in the original factory
configuration. If the cable gland nut is fitted without the rain protection filler or the
protection cover in place, reassemble them as illustrated in ‘Figure 2.7.’
Do not work by yourself
Do not work by yourself in any key process.
Caution for cleaning the Rack
Make sure that worker does not damage installed cables while cleaning the rack.
Cautions When Connecting the CRPI Cable
Failure to observe the CPRI cable connection specified in Table 2.5 may impair
the communication between the CDMA and LTE FDD terminal.

Ver.
SAFETY CONCERNS
X© SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
RRH-P4 optic cable connection standard
Cable connection standard between UADU CPRI port and RRH-P4 optic port is
different according to the count (One or two) of CDMAUADU (Installed in DU
cabinet).
Connect the optic cable (Refer to the connection standard of ‘table 2.6’ and ‘table
2.7’). Because false connection can cause the fault of call connection, be cautious.
Caution when Installing the RF antenna
To protect from lightning, the RF antenna must be installed within the shielding
angle as shown below, considering the downward distance and the angle from
the tower lightning rod or the antenna pole lightning rod.
- The protection angle of the lightning rod should be 45 degrees.
Finishing Heat Shrink Tube of a Sector Antenna
1) Insert an antenna protection plate.
2) Place the heat shrink tube on the connection point and shrink the heat shrink
tube using a heat gun.
3) Avoid aiming the heating gun toward the antenna’s body.
California USA Only
This Perchlorate warning applies only to primary CR (Manganese Dioxide)
Lithium coin cells in the product sold or distributed ONLY in California USA
‘Perchlorate Material-special handling may apply, See
www.dtsc.ca.gov/hazardouswaste/perchlorate.’

Ver.
Smart MBS RRH-P4 Installation Manual
© SAMSUNG Electronics Co., Ltd. XI
2600-00CTEIGAA
4.0
TABLE OF CONTENTS
INTRODUCTION I
Purpose....................................................................................................................................... I
Document Content and Organization .......................................................................................... I
Conventions................................................................................................................................ II
Revision History......................................................................................................................... III
SAFETY CONCERNS V
Symbols......................................................................................................................................V
Warning .....................................................................................................................................VI
Caution.....................................................................................................................................VII
California USA Only....................................................................................................................X
CHAPTER 1. Before Installation 1-1
1.1 System Configuration............................................................................................................ 1-1
1.2 Specifications......................................................................................................................... 1-3
1.3 Cabling.................................................................................................................................... 1-5
1.4 Installation Precaution .......................................................................................................... 1-7
1.5 Installation Tool.................................................................................................................... 1-12
CHAPTER 2. Installation of RRH-P4 2-1
2.1 Installation Procedure........................................................................................................... 2-1
2.2 Foundation Work ................................................................................................................... 2-2
2.2.1 Equipment Arrangement............................................................................................. 2-2
2.3 Unpacking and Transporting ................................................................................................ 2-3
2.3.1 Importing Items........................................................................................................... 2-3
2.3.2 Unpacking Items......................................................................................................... 2-3
2.4 Cable Gland Assembly and Cable Installation.................................................................... 2-4
2.4.1 Cable Gland Parts ...................................................................................................... 2-5
2.4.2 Cable GlandAssembly and Cabling Procedure.......................................................... 2-6

Ver.
TABLE OF CONTENTS
XII © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
2.4.3 Checking andAssembling Unused Cable Gland.........................................................2-9
2.5 Fixing the System.................................................................................................................2-10
2.5.1 Fixing Wall Mount......................................................................................................2-10
2.5.2 Fixing 1 Sector Pole..................................................................................................2-13
2.6Connecting cable between RRH and Antenna...................................................................2-16
2.6.1 Connecting Feeder Line............................................................................................2-16
2.6.2 Connecting RET cable...............................................................................................2-21
2.7Connecting Ground Cable...................................................................................................2-24
2.7.1 Grounding RRH-P4...................................................................................................2-24
2.8Connecting Hybrid cable .....................................................................................................2-26
2.8.1 Installing Hybrid cable...............................................................................................2-26
2.8.2 Connecting DU Cabinet side cable............................................................................2-31
2.8.3 Connecting RRH-P4 Power Cable ............................................................................2-37
2.8.4 Connecting RRH-P4 CPRI cable...............................................................................2-57
2.8.5Hybrid Cable Shield Grounding Connection..............................................................2-63
2.8.6 Remaining Hybrid cable............................................................................................2-65
2.9Installation Test ....................................................................................................................2-68
ANNEX A. Sector Antenna Installation A-1
A.1 Cautions when Installing a Sector Antenna........................................................................A-1
A.2 Sector Antenna Layout .........................................................................................................A-1
A.3 Sector Antenna Installation ..................................................................................................A-2
ANNEX B. Feeder Line Work B-1
B.1 When installing the feeder, the cautions.............................................................................B-1
B.2 Antenna Feeder Cable Ground.............................................................................................B-5
B.3 Tower Ground Construction.................................................................................................B-9
ANNEX C. Assembling connector C-1
C.1 RJ-45 (Shield type)................................................................................................................C-1
C.2 RJ-45 (Normal type)...............................................................................................................C-3
C.3 N type-male (LMR-400)..........................................................................................................C-4
C.4 TNC-male (LMR-400) .............................................................................................................C-6
C.5 N type-male (1/2 in. feeder line)............................................................................................C-8
C.6 Din type-male (1/2 in. Feeder Line) ....................................................................................C-12

Ver.
Smart MBS RRH-P4 Installation Manual/Ver.3.0
© SAMSUNG Electronics Co., Ltd. XIII
2600-00CTEIGAA
4.0
C.7 Finishing connector connection with the tape..................................................................C-14
C.8 How to Shrink the Heat Shrink Tube..................................................................................C-15
C.8.1 When assembling a connector to the feeder line......................................................C-15
C.8.2 When connecting a connector to another connector.................................................C-17
ANNEX D. Cleaning Optic Connector D-1
D.1 Cleaning Optic Connector.....................................................................................................D-1
D.2 IBCTM Brand Cleaner..............................................................................................................D-3
D.2.1 IBCTM brand type cleaner (P/N 9393).........................................................................D-3
ANNEX E. Pressure Terminal Assembly E-1
E.1 Preparations...........................................................................................................................E-1
E.2 Pressure Reference Table.....................................................................................................E-2
E.3 Assembling Pressure Terminal.............................................................................................E-5
ANNEX F. Standard Torque F-1
ABBREVIATION I
C ~ R .......................................................................................................................................... I
T ~ U ......................................................................................................................................... II
LIST OF FIGURES
Figure 1.1 RRH-P4 Configuration........................................................................................... 1-1
Figure 1.2 External Interfaces of RRH-P4.............................................................................. 1-2
Figure 1.3 Cabling Diagram.................................................................................................... 1-5
Figure 2.1 System Installation & Cable Connection Procedure.............................................. 2-1
Figure 2.2 RRH-P4 Installation Space (1 sector pole type)................................................... 2-2
Figure 2.3 Cable Gland Parts................................................................................................. 2-5
Figure 2.4 Cable GlandAssembly and Cable Installation Procedure (1)................................ 2-6
Figure 2.5 Cable GlandAssembly and Cable Installation Procedure (2)................................ 2-7
Figure 2.6 Cable GlandAssembly and Cable Installation Procedure (3)................................ 2-8
Figure 2.7 Checking andAssembling Unused Cable Gland................................................... 2-9
Figure 2.8Fixing Wall Mount (1)......................................................................................... 2-10

Ver.
TABLE OF CONTENTS
XIV © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
Figure 2.9Fixing Wall Mount (2)..........................................................................................2-11
Figure 2.10 Fixing 1 sector pole (1) ......................................................................................2-13
Figure 2.11 Fixing 1 sector pole (2).......................................................................................2-14
Figure 2.12 RRH-P4 Feeder Line Connection Diagram........................................................2-16
Figure 2.13 Connecting RRH-P4 Feeder Line (1).................................................................2-17
Figure 2.14 Connecting RRH-P4 Feeder Line (2).................................................................2-18
Figure 2.15 Connecting RET cable.......................................................................................2-21
Figure 2.16 RET Cable connector.........................................................................................2-22
Figure 2.17 Connecting RRH-P4 Ground cable....................................................................2-24
Figure 2.18Installing Hybrid cable (1) ..................................................................................2-26
Figure 2.19Installing Hybrid cable (2) ..................................................................................2-27
Figure 2.20 Installing Hybrid cable (3) ..................................................................................2-28
Figure 2.21 Installing Hybrid cable (4) ..................................................................................2-29
Figure 2.22 Peeling off the Hybrid Cable Sheath..................................................................2-32
Figure 2.23 Connecting Hybrid cable (1) ..............................................................................2-33
Figure 2.24 Connecting Hybrid cable (2) ..............................................................................2-34
Figure 2.25 Connecting Hybrid cable (3) ..............................................................................2-35
Figure 2.26 Connecting Hybrid cable (4) ..............................................................................2-35
Figure 2.27 Connecting RRH-P4 power cable (AWG8) (1)...................................................2-37
Figure 2.28 Connecting RRH-P4 power cable (AWG8) (2)...................................................2-38
Figure 2.29 Connecting RRH-P4 power cable (AWG8) (3)..................................................2-39
Figure 2.30 Connecting RRH-P4 power cable (AWG8) (4)..................................................2-40
Figure 2.31 Connecting RRH-P4 power cable (AWG8) (5)..................................................2-41
Figure 2.32 Connecting RRH-P4 power cable (AWG8) (6)..................................................2-42
Figure 2.33 Connecting RRH-P4 power cable (AWG8) (7)..................................................2-43
Figure 2.34 Connecting RRH-P4 power cable (AWG10) (1).................................................2-46
Figure 2.35 Connecting RRH-P4 power cable (AWG10) (2).................................................2-48
Figure 2.36 Connecting RRH-P4 power cable (AWG10) (3).................................................2-49
Figure 2.37 Connecting RRH-P4 power cable (AWG10) (4).................................................2-51
Figure 2.38 Connecting RRH-P4 power cable (AWG10) (5).................................................2-52
Figure 2.39 Connecting RRH-P4 power cable (AWG10) (6).................................................2-53
Figure 2.40 Connecting RRH-P4 power cable (AWG10) (7).................................................2-54
Figure 2.41 Connecting RRH-P4 CPRI cable (1)..................................................................2-57
Figure 2.42 Connecting RRH-P4 CPRI cable (2)..................................................................2-59
Figure 2.43 Hybrid Cable Shield Grounding Connection_DU Cabinet..................................2-63
Figure 2.44 Hybrid Cable Shield Grounding Connection_Tower Ground Bar........................2-64
Figure 2.45 Remaining Hybrid cable (1) ...............................................................................2-65
Figure 2.46 Remaining Hybrid cable (2) ...............................................................................2-66
Figure 2.47 Remaining Hybrid cable (3) ...............................................................................2-67

Ver.
Smart MBS RRH-P4 Installation Manual/Ver.3.0
© SAMSUNG Electronics Co., Ltd. XV
2600-00CTEIGAA
4.0
Figure 2.48 RRH-P4 Power Section Test ............................................................................. 2-69
Figure A.1 Sector Antenna .....................................................................................................A-2
Figure B.1 Feeder Cable Grounding (1).................................................................................B-5
Figure B.2 Feeder Cable Grounding (2).................................................................................B-6
Figure B.3 Feeder Cable Grounding (3).................................................................................B-7
Figure B.4 Feeder Cable Grounding (4).................................................................................B-8
Figure B.5 Connecting the Tower Ground Cable....................................................................B-9
Figure C.1 Assembling the RJ-45 Connector (Shield Type) (1)..............................................C-1
Figure C.2 Assembling the RJ-45 Connector (Shield Type) (2)..............................................C-2
Figure C.3 Assembling the RJ-45 connector (Normal type)...................................................C-3
Figure C.4 Assembling the N type-male connector (LMR-400) (1).........................................C-4
Figure C.5 Assembling the N type-male connector (LMR-400) (2).........................................C-5
Figure C.6 Assembling the TNC-male connector (1)..............................................................C-6
Figure C.7 Assembling the TNC-male connector (2)..............................................................C-7
Figure C.8 Assembling the N type-male Connector (1/2 in. Feeder Line) (1).........................C-8
Figure C.9 Assembling the N type-male Connector (1/2 in. Feeder Line) (2).........................C-9
Figure C.10 Assembling the N type-male Connector (1/2 in. Feeder Line) (3).....................C-10
Figure C.11 Assembling the N type-male Connector (1/2 in. Feeder Line) (4).....................C-11
Figure C.12 Assembling the Din type-male Connector (1/2 in. Feeder Line) (1)..................C-12
Figure C.13 Assembling the Din type-male Connector (1/2 in. Feeder Line) (2)..................C-13
Figure C.14 Finishing connector connection with the tape...................................................C-14
Figure C.15 Shrinking the Heat Shrink Tube-Feeder line (1)................................................C-15
Figure C.16 Shrinking the Heat Shrink Tube-Feeder line (2)................................................C-16
Figure C.17 Shrinking the Heat Shrink Tube-Connector (1).................................................C-17
Figure C.18 Shrinking the Heat Shrink Tube-Connector (2).................................................C-18
Figure C.19 Shrinking the Heat Shrink Tube-Connector (3).................................................C-19
Figure D.1 Optic Connector Cleaner (IBCTM Brand Type Cleaner: P/N 9393)........................D-3
Figure D.2 Optic Module Cleaning (LC type Jack) .................................................................D-4
Figure D.3 Optic Cable Connector Cleaning (LC type plug)...................................................D-5
Figure D.4 Measuring the Optical Output and Connecting the Optic Connector....................D-6
Figure E.1 Preparations..........................................................................................................E-1
Figure E.2 Pressure Reference Drawing (Handheld Compressor).........................................E-2
Figure E.3 Pressure Reference Drawing (Hydraulic Press) ...................................................E-3
Figure E.4 Stripping Cable Sheath (1)...................................................................................E-5

Ver.
TABLE OF CONTENTS
XVI © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
Figure E.5 Stripping Cable Sheath (2)................................................................................... E-6
Figure E.6 Fixing Pressure Terminal_Handheld Compressor (1).......................................... E-8
Figure E.7 Fixing Pressure Terminal_Handheld Compressor (2).......................................... E-9
Figure E.8 Fixing Pressure Terminal_Hydraulic Press (1).....................................................E-11
Figure E.9 Fixing Pressure Terminal_Hydraulic Press (2).................................................... E-12
Figure E.10 Assembling Heat Shrink Tube.......................................................................... E-14
LIST OF TABLES
Table 1.1 System Cabling.......................................................................................................1-6
Table 1.2 Minimum Allowed Cable Bend Radius.....................................................................1-9
Table 1.3 Basic Installation Tools ..........................................................................................1-12
Table 2.1 Recommended Distances for System Arrangement................................................2-2
Table 2.2 GPS Identification Tag of Feeder line....................................................................2-20
Table 2.3 RET Cable-Side Connector Pin Map.....................................................................2-22
Table 2.4 Hybrid Cable Color Map ........................................................................................2-34
Table 2.5 CPRI Cable connection configuration....................................................................2-60
Table 2.6 CPRI cable connection standard-When CDMA DU Shelf is one............................2-60
Table 2.7 CPRI cable connection standard-When CDMA DU Shelf is two............................2-61
Table 2.8 Construction Status Checklist................................................................................2-70
Table B.1 Curvature Radius of Feeder Cable for Outdoor...................................................... B-2
Table B.2 Curvature Radius of Feeder Cable for Indoor........................................................ B-3
Table B.3 Curvature Radius of LMR-400 (Based on Times Microwave system).................... B-3
Table B.4 Connector Connection Torque Value...................................................................... B-4
Table B.5 TGB Installation Example....................................................................................... B-8
Table E.1 Pressure Reference Table for Pressure Terminal................................................... E-2
Table E.2 Compressor Specifications per Cable Thickness................................................... E-4
Table F.1 Standard Torque Value for Tightening Bolts............................................................ F-1
Table F.2 Brass Bolts Torque.................................................................................................. F-1

Ver.
Smart MBS RRH-P4 Installation Manual
© SAMSUNG Electronics Co., Ltd. 1-1
2600-00CTEIGAA
4.0
CHAPTER 1. Before Installation
1.1 System Configuration
RRH-P4 Configuration
The following shows the configuration of RRH-P4.
Figure 1.1RRH-P4 Configuration
[Top View]
[Front View]
[Bottom View]
[Right View]
[Left View]
[Rear View]
23.81 (605)
8.96 (227.5)
13.78 (350)
Unit:in. (mm)

Ver.
CHAPTER 1. Before Installation
1-2 © SAMSUNG Electronics Co., Ltd.
2600-00CTEIGAA
4.0
External Interfaces of RRH-P4
The following shows the external interfaces of RRH-P4.
Figure 1.2 External Interfaces of RRH-P4
[Bottom View]
POWER
[-48 V]
ANT 3
OPTIC
RETGround
ANT 2
ANT 1
ANT 0
Table of contents
Popular Industrial Equipment manuals by other brands

Tin Knocker
Tin Knocker TK 422 Instructions & parts diagrams

INTORQ
INTORQ BFK455-28 Translation of the original operating instructions

cytiva
cytiva UniFlux10 operating instructions

Edge Technologies
Edge Technologies V-65 Series Operation manual

ROBOTIQ
ROBOTIQ POWERPICK10 instruction manual

Lillbacka Powerco
Lillbacka Powerco Finn-power P51MS manual