Sargent and Greenleaf 2890C User manual

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 1/7
2890C SCIF-High Security Door Lock Installation Instructions
Refer to sargentandgreenleaf.com for additional information on the 2890C & FF-L-2740B High Security Combination Lock
Tools
Needed
Center Punch Metal File
Threadlocker
#10-32 Tap
The 2890C SCIF-High Security Door Lock is designed to
use a High Security Combination Lock. Follow the
instructions packaged with the combination lock for
installation in the 2890C SCIF-Lock device. Wear a static
discharge wrist strap (included) during combination lock
installation. The strap should be grounded to bare metal
of the door to which the 2890C SCIF-Lock is attached.
This should greatly reduce the possibility of static
discharge.
For drilling instructions and templates please refer to
document 630-880 (2890C SCIF-High Security Door
Lock Drilling Instructions/Templates).
1/8"
9/64"
3/16"
3/8"
For detailed info on the High Security Combination Lock
please refer to Operating Instructions document contained
inside the High Security Combination Lock Package.
High Security Combination Lock
#10 X 1"Phillips Flat Head Thread Forming Screw (Qty 17)
Washer, Tabbed (Qty 4)
#1/4-20 x 1/2"Phillips Truss Head Machine Screw (Qty 4)
#10-32 x 1/4"Phillips Flat Head Machine Screw (Qty 16)
A4
B1
B2
F1
#8-32 x 1/2" Phillips Flat Head Machine Screw (Qty 2)
Washer, Lock, Countersink (Qty 2)
#10-32 x 1/2" Phillips Flat Head Machine Screw (Qty 4)
#8-32 x 3/8" Phillips Pan Head Machine Screw (Qty 2)
S1
S2
V1
W2
#10-32 x 1/2" Phillips Pan Head Machine Screw (Qty 2)
W3
#1/4-20 x 1" Phillips Pan Head Machine Screw (Qty 4)
Bolt Extension (Qty 1)
#10-32NF x 1" Phillips Flat Head Machine Screw (Qty 2)
#10-32 x 1/4" Phillips Pan Head Machine Screw (Qty 2)
F2
L
L1
Q2
Tools
Recommended
A
B
F
G
K
L
N
P
Q
R
S
T
U
V
W
XY
R1
A1(4x)
B1(4x)
B2(4x)
A3(4x)
A4(6x)
F1(4x)
F1(2x)
F1(2x)
A4(5x)
E
H
J
A4(2x)
E1(2x)
Q1
F1(4x)
Q3(4x)
Q2(2x)
V1(4x)
A4(2x)
Z1(2x)
X1(2x)
Optional: 2890C SCIF-Lock
Panic Exit Device
A4(2x)
F2(4x)
Z
C
M
A2
A5
S2(2x)
W3(2x)
W2(2x)
W1
L1(2x)
S1(2x)
A4
B1B2
F1
L
L1
F2
Q2S1
S2V1W2W3
*D
* not included
with all kits
Exterior Mounting Plate
Depth Adjusters
Exterior Handle Assembly
Screw 1/4-20 x 1/2"
Exterior Spindle
Interior Mounting Plate
Exterior Escutcheon
Rim Cylinder or Plug
*not included with all kits
Access Control Assembly
Screw #10-32 x 1", Washers
Mechanical Assembly
Lock Housing
Access Control Housing
Access Control Cover
High Security
Combination Lock
Combination Lock Dial Ring
Combination Lock Dial
A
A1(4x)
A2
A3(4x)
A5
B
C
D
E
E1(2x)
F
G
H
J
K
M
N
Combination Lock Cover
Interior Center Cover
Lever Handle
Screw #10-32 x 1/4" Flat Head
Strike
Strike Spacers
Panic Mechanism Cover
Panic Mechanism
Short Spindle
Panic Mechanism Shim
Panic Bar
Panic Interface Mechanism
Panic Bar Channel Bracket
Architectural Bolt #10-24 x 1"
Filler Panel
End Cap
Screw #10-24 x 3/8"
P
Q
Q1
Q3(4x)
R
R1
S
T
U
V
W
W1
X
X1(2x)
Y
Z
Z1
Cut exterior spindle where
marked, use metal file to
smooth edges. After cutting,
insert exterior spindle into handle
drive hole.
2
Make sure exterior
spindle is fully seated
inside handle. Measure
door thickness and add 5/8".
Using this dimension, mark
spindle from surface of
exterior mounting plate.
A
1
OR
Verify that handle on exterior mounting plate is
oriented correctly. If not, remove 4 screws, rotate
handle, and re-install. Threadlocker is recom-
mended on these screws.
3
A3

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 2/7
Install (4) 1/4"-20 x 1/2" screws,
loosely fasten through door to
the exterior mounting plate
assembly.
Place a tabbed washer in
each of the (4) mounting
holes, with the small tab in
adjuster slot.
Level interior mounting
plate and exterior
mounting plate assembly.
B1B2
B B
B
A
7 8 9
Center
punch and
pre-drill
mounting holes
(6x) using exterior
mounting plate
assembly holes as
guide. For steel
door drill Ø9/64",
for wood door drill
Ø1/8". Gauge hole
depth by length of
mounting screws.
A
A4
Install (2) #10 sheet
metal screws and
tighten securely.
Center punch and
pre-drill interior
mounting plate
mounting holes (2x).
B2
B
Tighten (4) screws
securely, making
sure both sides stay
BB
10 11 12 13
Remove 2 screws to
release interior mounting
plate from mechanical
assembly.
6
From interior side,
use flat blade
screwdriver to
adjust (4) depth adjusters
until they are flush with
interior door face. Leave
each depth adjuster with
slot in vertical position.
5
Align
exterior
mount-
ing plate
assembly to
the through
holes on door
exterior.
Position
exterior
mounting
plate
assembly
flush against
exterior side
of door.
A
4
Heavy gage metal doors may
require tapped holes and machine
C
14 16
D
Install the rim
cylinder or
plug through
the exterior
escutcheon.
C
A
Slip the exterior escutcheon around
the handle and position over the
exterior mounting plate assembly.
15
A4
A
Install (6) #10 sheet
metal screws and
tighten securely.
A1
B
Position interior
mounting plate on door
and align with (4) depth
adjusters. Make sure
exterior spindle fits
through bottom center
hole.
B
F
Locate the access control assembly,
remove (2) screws and temporarily
remove access control assembly. Set
Orient mechanical assembly, depending
upon specific application installation.
H
H
E1
EF
F
18 19
From door interior, install
the rim cylinder retainer
plate. Install (2) rim cylinder
mounting screws and tighten
securely. Check to make sure the
key turns easily, make rim cylinder
retainer plate adjustments as
needed to ensure smooth key
operation.
17
This unit accommodates retainer
plates with max thickness of 1/8"
and max diameter of 2-1/2"
Rim cylinder spindle must extend
5/8" to 1-1/8" from the surface of
door when installed.
B

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 3/7
F2
Attach the
mechanical
assembly to the
interior mounting plate as
in previous step, install (4)
#10 sheet metal screws
and tighten securely.
Connect the cables to
the PCBA. Position the
assembly over the rim
cylinder spindle. This can be
made easier by unlocking the
assembly and depressing the
bolt.
Secure access control
assembly with (2) #10-32 x
1" pan head screws and (2)
star washers.
At this point, the access
control assembly could
be connected to a 12-24V
power supply and an
authentication device.
Refer to Access Control
Wiring on page 7.
Secure access
control cover to
access control
housing with (2)
#10-32 x 1/4" flat
head screws.
J
Remove the combined
assembly before drilling in
order to prevent any drill
chips from getting into the
2890C mechanism.
Pre-Drill mounting holes (4x) as
marked. For steel door drill
Ø9/64", for wood door drill Ø1/8".
Gauge hole depth by length of
mounting screws.
Locate the previously removed
access control assembly and
position it with the vertical
side of the access bolt facing the
door hinge.
Install access
control cover.
Center punch mounting holes
(4x) using housing holes as
guide.
23 24
25
A4
A4
E
EE1
26 27
28 29 30
31
F1
Position lock
housing above
mechanical
assembly and access
control housing below
mechanical assembly.
Flip the combined assembly over and
secure housings together with
(4) #10-32 x 1/4" screws.
H
G
F1
F
20 21
H
F
G
Position the combined
assembly over the interior
mounting plate. Align the
exterior spindle with the square
hole on the mechanical assembly
and ensure the rim cylinder tab
extends through the hole in
access control housing. Install (4)
1/4"-20 x 1" screws into threaded
holes, tighten securely.
B
22
If access control is installed
backwards, it will not function.
Attach bolt extension to high
security combination lock bolt.
Orient as shown. Secure with (2)
#10-32 screws.
Threadlocker is recommended on
these screws.
33
Place gear in lock
housing.
32
The spindle gear
is only to be used
with locks having
compatible
spindles including
the S&G 2740B. L
K

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 4/7
Verify that the interior center cover, handle, and blind
rose are oriented correctly. If not, remove 4 screws to
rotate and reposition the handle, and 2 screws to
remove and reposition the blind rose. Threadlocker is
recommended on these screws.
37
OR
F1
36 Secure combination lock
cover with (2) #10-32 x
1/4" flat head screws.
Position strike on frame with bolt
extended into strike. Align strike with
equal space top and bottom of bolt.
bolt
strike
40
39
Secure interior center
cover to mechanical
assembly with (4) #10-32
flathead screws and (2)
#10-32 pan head screws.
Q2
Q3
Install interior
center cover
or refer to
step 55-74 for
panic exit device
installation. Refer
to steps 40-52 for
strike installation.
Q
Q1
38
Level strike.
46 Center punch
bottom left slotted
strike mounting
hole (1x).
47 Pre-Drill for #10
sheet metal screw or
drill & tap for #10-32
machine screw.
48
Mark and pre-drill remaining mounting
holes (3x) using strike holes as guide.
51
Close door and engage
lock with strike.
Manually position
strike for best engagement.
Add/remove strike spacers
as necessary. Once aligned,
tighten (2) previously
installed screws.
50
Retract bolt, open
door, and realign
strike to reference
lines on frame.
Center punch top left
slotted strike
mounting hole (1x).
42
Mark strike position
reference lines
on frame.
41 43 Pre-Drill for #10 sheet
metal screw or drill &
tap for #10-32
machine screw.
Spacers are used
to adjust
clearance
between the
strike & lock and
are not required
for every
Align strike spacers
and strike to
previously drilled
hole on door frame.
44 Install (1) screw, top left.
A4
45
Install (1) screw, bottom left.
A4
49
Change lock
combination and
install combination
lock cover.
P
Refer to High Security
Combination Lock Operating
Instructions for detailed
instructions on changing
lock combination.
Verify lock operation per
High Security Lock
Instructions.
35
F1
Insert high security
combination lock into lock
housing, with the bolt
extension extending down into the
mechanical assembly.
To thread dial/spindle assembly
into lock cam, spindle slots must
align with gear’s internal tabs.
From front of door, inspect
orientation of gear tabs. Insert
spindle through door with slots in
approximate alignment with tabs.
Gently push spindle into gear and
rotate as needed to align slot with
tabs. When aligned, spindle will
slip through gear to threaded hole
of lock cam.
34
Refer to High Security
Combination Lock -
Installation Instructions for
detailed instruction.

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 5/7
Temporarily attach panic bar assembly to interior mounting plate
using (2) #10-32 x 1/2" screws.
Slide panic bar touch pad back into panic bar channel, insert panic bar channel bracket and
filler panel into panic bar channel.
58
Level panic bar assembly.
61
Secure strike with (3)
remaining #10 sheet metal
screws or #10-32 machine
screws, tighten securely. If
machine screws are used,
threadlocker is recom-
mended.
A4
52
Slide panic bar touch pad partially from panic bar channel.
W
55
F
Adjust trip mechanism to engage
strike. Slowly close door, observe whether
the bolt is released upon closing. If bolt is
not released, use a flat blade screwdriver
and rotate the trip mechanism counter
clockwise 1/2 turn. Repeat adjustment
until bolt is extended upon door closing
and rotate trip mechanism 1 additional full
turn counter clockwise.
Test all door and lock functions for
proper operation. Make necessary
adjustments if required.
53 54
To access High Security Combina-
tion Lock: Unlock center module
and upper module with key,
remove (6) interior module cover
assembly screws and (2) lock
cover screws. Time to preform
this operation is 1 min 10 sec.
Reverse process to re-install
covers. Refer to High Security
Combination Lock - Operating
Instructions for detailed instruc-
tion, including how to change lock
combination.
W
X
Y
Align panic bar assembly to lock assembly.
59
Align panic interface mechanism to panic bar touch pad. From backside of panic bar touch pad, secure panic
interface mechanism with (2) #8-32 x 3/8" screws.
W1
W
W2
W2
W1
W
56 57
W3
W3
60

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 6/7
Re-install panic bar assembly and secure
with (2) #10-32 x 1/2" screws.
Secure panic bar channel
bracket to door with (2)
architectural bolts #10-24 x 1".
X1
64 65
Remove panic bar assembly.
Drill (2) mounting holes Ø3/8"
through door, as marked.
Mark panic bar
channel bracket hole
locations.
62 63
W3
Verify that interior center cover and panic
mechanism shim are oriented correctly. If
not, remove screws, rotate, and re-install.
Align panic mechanism shim to interior center
cover.
Align interior center cover
assembly to mechanical assembly.
V
Q
UV
Q
V
Q
TU
Q
TV1
Q2
Q3
Z
Z1
S1
66 Insert short spindle.
67
70 71
Install endcap.
72
Install interior center cover assembly. Ensure that the exit module
engages the spindle and panic mechanism. Secure with (2) #10-32 x
1/4" pan head screws and (3) #10-32 x 1/4" flathead screws.
Align panic mechanism to panic
mechanism shim.
Secure panic mechanism shim and
panic mechanism to interior center
cover using (4) #10-32 x 1/2" flat
head screws.
Cam lock must be in the unsecured position.
Secure endcap to panic bar
channel bracket using (2) #10-24
x 3/8" flat head screws.
Install panic mecha-
nism cover.
Secure panic mechanism cover to
panic mechanism using (2) #8-32 x 1/2"
screws and star washers.
68 69
73 74 75
OR
S

Document 630-881
Revised 09/17/2021
Copyright©2021, Sargent & Greenleaf 7/7
3 NC
4 NO
5 COM
6 RES
alarm panel
3 NC
4 NO
5 COM
6 RES
alarm panel
3 NC
4 NO
5 COM
6 RES
alarm panel
R1
R2
R1R2
R1R2
3 NC
4 NO
5 COM
6 RES
alarm panel
R1
R2
3 NC
4 NO
5 COM
6 RES
alarm panel
R1
R1
3 NC
4 NO
5 COM
6 RES
alarm panel
R1
R1
For assistance or warranty information:
Call 1-859-885-9411 or visit
www.sargentandgreenleaf.com
Warning: This Manufacturer advises that no lock can provide complete security by itself. This lock may be
defeated by forcible or technical means, or evaded by entry elsewhere on the property. No lock can
substitute for caution, awareness of your environment, and common sense. Builder’s hardware is available in
multiple performance grades to suit the application. In order to enhance security and reduce risk, you should
consult a qualified locksmith or other security professional.
Si desea ayuda o información sobre la garantia:
llame al 1-859-885-9411 ou visite
www.sargentandgreenleaf.com
Advertencia: Este fabricante have saber que no hay cerraduras que puedan proporcionar seguridad
completa por si misma. Esta cerradura puede fallar forzandola o utilizando medios técnicos o entrando por otra
parte del edificio. No hay cerraduras que puedan sustituir precaución, estar al tanto de su entorno y sentido
común. Este fabricante también ofrece cerraduras de diferentes grados y rendimientos para ajustarse a su
aplicación. Para mejorar la seguridad y reducer riesgos, usted debe consultar con un cerrajero especializado u
otro profesional de seguridad.
Pour de l'aide ou des informations sur la garantie:
Vauillez appeler le 1-859-885-9411 ou visiter
www.sargentandgreenleaf.com
Advertissement:
Le fabricant tient à vous aviser qu'aucun verrou ne peut à lui seul offrir une sécurité complète.
Ce verrou peut être mis hors d'état par la force ou des moyens techniques ou etre évité par l'utilisation d'une autre
entrée sur la propriété. Aucun verrou ne peut remplacer la surveillance de votre enviornnenment et le bon sens. La
quincaillerie pour le constructeur est offerte selon différents grades de performance pour différentes applications.
Afin d'augmenter la sécurité et de rduire le risque, vous devriez consulter un serrurier qualifié ou un autre
professionel de la sécurité.
Test all door and lock functions for proper operation.
Make necessary adjustments if required.
To access High Security Combination
Lock: Remove (2) panic mechanism
cover screws. Unlock center module and
upper module with key, remove (5)
interior center module cover assembly
screws, and (2) lock cover screws. Time
to preform this operation is 1 min 10 sec.
Reverse process to re-install covers.
Refer to High Security Combination Lock
- Operating Instructions for detailed
instruction, including how to change
lock combination.
76
Requirements:
Operating Voltage 12-24 VDC
Conductors 18-22 AWG
1. - V
2. + V
3. Normal Closed (NC)
4. Normal Open (NO)
5. Common (COM)
6. Resistor (RES)
3 4 5 6
1
2
Alarm Panel Wiring Options
Access Control Wiring