manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sargent
  6. •
  7. Door Opening System
  8. •
  9. Sargent ASSA ABLOY 8800 Series User manual

Sargent ASSA ABLOY 8800 Series User manual

This manual suits for next models

1

Other Sargent Door Opening System manuals

Sargent 1431 series User manual

Sargent

Sargent 1431 series User manual

Sargent 2600 Series Guide

Sargent

Sargent 2600 Series Guide

Sargent Fireguard 2900 Series User manual

Sargent

Sargent Fireguard 2900 Series User manual

Sargent POWERGLIDE 281 User manual

Sargent

Sargent POWERGLIDE 281 User manual

Sargent 3828 Series Instruction Manual

Sargent

Sargent 3828 Series Instruction Manual

Sargent ASSA ABLOY 3727 Series Instruction Manual

Sargent

Sargent ASSA ABLOY 3727 Series Instruction Manual

Sargent POWERGLIDE Series Instruction Manual

Sargent

Sargent POWERGLIDE Series Instruction Manual

Sargent 1130 Series User manual

Sargent

Sargent 1130 Series User manual

Sargent 1431 series User manual

Sargent

Sargent 1431 series User manual

Popular Door Opening System manuals by other brands

Mobeye Call-Key MCK100 installation manual

Mobeye

Mobeye Call-Key MCK100 installation manual

SALICE Lapis Assembly instructions

SALICE

SALICE Lapis Assembly instructions

Cal-Royal N-F77CVR Installation instruction

Cal-Royal

Cal-Royal N-F77CVR Installation instruction

Scrigno OPEN1000 Assembly manual

Scrigno

Scrigno OPEN1000 Assembly manual

BFT WIND RMB 130B 200 installation manual

BFT

BFT WIND RMB 130B 200 installation manual

Alecto ADI-250 user manual

Alecto

Alecto ADI-250 user manual

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Besam

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Assa Abloy SARGENT 1431 Series instructions

Assa Abloy

Assa Abloy SARGENT 1431 Series instructions

GAL MOVFR Quick setup

GAL

GAL MOVFR Quick setup

Häfele Finetta T 70 VF manual

Häfele

Häfele Finetta T 70 VF manual

AGS D-PL Instructions for fitting, operating and maintenance

AGS

AGS D-PL Instructions for fitting, operating and maintenance

Stanley MA900ñ Installation and owner's manual

Stanley

Stanley MA900ñ Installation and owner's manual

WITTUR Hydra Plus UD300 Instruction handbook

WITTUR

WITTUR Hydra Plus UD300 Instruction handbook

Alutech TR-3019-230E-ICU Assembly and operation manual

Alutech

Alutech TR-3019-230E-ICU Assembly and operation manual

Pamex KT-INP35 Installation instruction

Pamex

Pamex KT-INP35 Installation instruction

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

MPC

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

Chamberlain T user guide

Chamberlain

Chamberlain T user guide

Dorma MUTO COMFORT M DORMOTION 50 Mounting instruction

Dorma

Dorma MUTO COMFORT M DORMOTION 50 Mounting instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1Mark vertical and horizontal reference lines of the door (See Figure 1)
1-800-727-5477 • www.sargentlock.com
A6703H 07/21 Copyright © 2008, 2012, 2021 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express
written permission ofSARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.
Installation Instructions
8800 & 12-8800 Series
Rim Exit Device for 16, 28, 63, & 66 Functions
Before installation:
1. Install mullion, if used.
2. Fit and hang door.
3. Check the box’s label for the size of the exit device.
Available Stock Lengths:
Length “E”: 32” door, no cut off required. Can be cut to fit doors down to 24” wide.
Length “F”: 36” door, no cut off required. Can be cut to fit doors down to 33” wide.
Length “J”: 42” door, no cut off required. Can be cut to fit doors down to 37” wide.
Length “G”: 48” door, no cut off required. Can be cut to fit doors down to 43” wide.
Surface of the door where exit device is applied, must be flush. Clear away any raised projections to allow exit device to rest on
the flat surface of the door.
L
Product Overview
Figure1 Vertical & Horizontal Reference
Center chassis
assembly (8828)
Center chassis
assembly (8863)
Cover
(8826,8863) 649
Strike
Rim Cylinder
Center chassis
assembly
(8816,8866)
Cover
(8816,8866)
Collar
Mortise
Cylinder
aIdentify type of installation to determine the location of the vertical C.
End Cap
Mounting Plate
Rail Assembly
"Lock Down Key"
To operate: Depress pushrail; Insert hex key, and turn
counter clockwise.
Attention:
Not furnished with 12- (Fire Rated) Exit Devices.
37-5/8" 41"
1-800-727-5477 • www.sargentlock.com A6703H 07/21
Copyright © 2008, 2012, 2021 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express
written permission ofSARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.
WARNING
This product can expose you to lead
which is known to the state of California
to cause cancer and birth defects or other
reproductive harm. For more information go
to www.P65warnings.ca.gov.
16 Function
16, 28, 63 & 66 Functions
Mount rim cylinder with (2) screws through
chassis.
2Prepare Door
3Apply Hardware
4Apply Rail Assembly
• If cutting is not required, skip to 4b.
5Apply Covers and Strike
Installation Instructions
Horizontal reference line (37-5/8" from
finished floor for 41" height center of
push rail)
Vertical reference line C of chassis
L
aTape template on inside of the door along the reference.
bSpot and drill holes.
aAttach chassis to the door with (4) #10 mounting screws.
Through-bolt outside trim and cylinder chassis if used. Leave chassis
screws slightly loose until after step 4b.
aCheck box label for rail size and refer to the Available Stock Lengths on page 1 for the door sizes.
aAttach cover to chassis with four (4) cover screws.
bAttach end cap to mounting plate with two cover screws.
28, 63 & 66 Function
• If cutting is required, determine cut off dimension “X” by subtracting
1-3/4” from dimension “Y”. (See Figure 2.) Mark cut off point on mounting rail.
Depress arm into rail opening and slide rail onto chassis. Attach rail assembly to the
chassis with two #8 truss head machine screws.
Level rail. Place mounting plate tight against rail and attach it to the door
with two #10 round head screws.
Figure 2
Rail Assembly
Chassis
Machine Screw
b
c
Attach 649 Strike (for Fire Rated application) with (2) outer screws and
adjust for proper position. Drill and tap through the two holes in the
strike frame and fasten strike in place with (2) inner screws.
Attach 649 Strike (for non-Fire Rated application) with (2) strike screws
and two lock washers.
c
d
b