Bidirectional keyfob
Firmware version 1.00 apt-200_en 03/19
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu

IMPORTANT
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
The rating plate of the device is located inside the enclosure.
SATEL aims to continually improve the quality of its products, which may result in changes in
their technical specifications and software. Current information about the changes being
introduced is available on our website.
Please visit us at:
http://www.satel.eu
Hereby, SATEL sp. z o.o. declares that the radio equipment type APT-200 is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.satel.eu/ce
The following symbols may be used in this manual:
- note,
- caution.

The APT-200 keyfob allows you to remotely control the alarm system or automation devices.
It is designed for operation within the ABAX 2 / ABAX two-way wireless system. The keyfob
is supported by:
ABAX 2:
ACU-220 / ACU-280 controller,
ABAX:
ACU-120 / ACU-270 controller (firmware version 5.04 or newer),
INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware
version of processor used to operate ABAX system 3.10 or newer).
1 Features
Encrypted two-way radio communication in the 868 MHz frequency band (AES standard
for the ABAX 2 system).
Transmission channel diversity – 4 channels for automatic selection of the one that will
enable transmission without interference with other signals in the 868 MHz frequency
band (ABAX 2 system only).
5 buttons to start up to 6 functions.
3 LEDs indicating the alarm system status.
Built-in buzzer for audible feedback.
Buttons backlight.
Low battery indication.
2 Description
For description of adding and configuring the keyfobs, refer to the ABAX 2 / ABAX system
controller manual / INTEGRA 128-WRL control panel user manual.
Pressing the keyfob button will:
generate a beep,
turn on the buttons backlight,
make the LEDs blink three times,
send a radio transmission to the controller / alarm control panel.
As long as the button is pressed, the keyfob will keep sending information about this fact to
the controller / alarm control panel. If the button will be pressed for 20 seconds, the keyfob
will turn off to save battery power.
After the transmission is sent, the keyfob is waiting for an answer from the controller / control
panel. The keyfob will signal with different sounds whether it has received transmission
acknowledgement or not. Having received the system state information, the keyfob will
present it by means of LEDs.
Fig. 1 shows numeration of the keyfob LEDs (1-A) and buttons (1-B).
2.1 Control
ACU-220 controller
The description below does not apply to the ACU-220 controller connected to the
INTEGRA / INTEGRA Plus / VERSA / VERSA Plus / VERSA IP control panel.

2 APT-200 SATEL
The keyfob user can control the ACU-220 controller outputs. The five buttons make it
possible to control six outputs (to control the sixth output, press the and [1 and 5]
buttons simultaneously). Pressing the keyfob button(s) will turn on the output for a preset
time or toggle the output to its opposite state. You must define the output operating mode
when configuring the controller settings. For more information, refer to the ACU-220
controller manual.
ABAX 2 / ABAX controller connected to INTEGRA / INTEGRA Plus control panel
The keyfob user can control the alarm system zones. The five buttons make it possible to
control six zones (to control the sixth zone, press the and [1 and 5] buttons
simultaneously). The zones must not exist physically and their preprogrammed wiring type
must be different from “Not used” or “Follow output”. You can program any zone type for
them. Pressing the keyfob button(s) will violate the zone. The zone will remain violated as
long as the button is pressed. For more information, refer to the ABAX 2 / ABAX controller
manual and the INTEGRA / INTEGRA Plus control panel manuals.
INTEGRA 128-WRL control panel
The keyfob user can control the alarm system zones in the same way as in the case of
ABAX 2 / ABAX controller connected to the INTEGRA / INTEGRA Plus control panel. For
more information, refer to the INTEGRA 128-WRL control panel manuals.
ABAX 2 / ABAX controller connected to VERSA / VERSA Plus / VERSA IP
control panel
The keyfob user can run functions available in the control panel. The five buttons make it
possible to run six functions (to run the sixth function, press the and [1 and 5] buttons
simultaneously). If the function allows for zone violation, the zone must not exist physically
and its preset wiring type must be different from “Not used”. You can program any zone type
for the zone. The zone will remain violated as long as the button is pressed. For more
information, refer to the ABAX 2 / ABAX controller manual and the VERSA / VERSA Plus /
VERSA IP control panel manuals.

SATEL APT-200 3
2.2 System state information
To get the system state information, press any button (it needn't start any function). The
information will be presented by the keyfob LEDs for a few seconds.
ACU-220 controller
The description below does not apply to the ACU-220 controller connected to the
INTEGRA / INTEGRA Plus / VERSA / VERSA Plus / VERSA IP control panel.
The LEDs indicate the state of three selected zones of the ACU-220 controller. The LED is
ON when:
the NO type input is shorted,
the NC type input is open.
For more information, refer to the ACU-220 controller manual.
ABAX 2 / ABAX controller connected to INTEGRA / INTEGRA Plus control panel
The LEDs indicate the status of three selected outputs of the alarm system. The LED is ON
when:
output with normal polarity is active,
output with reversed polarity is inactive.
For more information, refer to the ABAX 2 / ABAX controller manual and the INTEGRA /
INTEGRA Plus control panel manuals.
INTEGRA 128-WRL control panel
The LEDs indicate the state of three outputs of the alarm system in the same way as in the
case of the ABAX 2 / ABAX controller connected to the INTEGRA / INTEGRA Plus control
panel. For more information, refer to the INTEGRA 128-WRL control panel manuals.
ABAX 2 / ABAX controller connected to VERSA / VERSA Plus / VERSA IP
control panel
For the list of information that can be presented on the keyfob LEDs, refer to the manuals of
VERSA / VERSA Plus / VERSA IP control panels.
3 Battery replacement
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
The battery life depends on how the keyfob is used. The more frequently the buttons are
pressed, the faster the battery drains.
When the battery is low, after pressing the button:
the buttons backlight will flash (instead of being solid),
the LBA output of the ACU-220 controller will turn on (if the keyfob is registered in the
ACU-220 controller),

4 APT-200 SATEL
the control panel will indicate trouble (if the keyfob is registered in the ABAX 2 / ABAX
controller, which is connected to the INTEGRA / INTEGRA Plus / VERSA / VERSA Plus /
VERSA IP control panel, or in the INTEGRA 128-WRL control panel).
The LBA output of the ACU-220 controller will turn off / the control panel will stop indicating
trouble only after the battery replacement.
Fig. 2 shows how to replace the battery.

SATEL APT-200 5
4 Specifications
Operating frequency band ...................................................................868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area)
ABAX 2
ACU-220 .............................................................................................. up to 1200 m
ACU-280 ................................................................................................ up to 600 m
ABAX.............................................................................................................. up to 150 m
Battery .....................................................................................................................CR2032 3V
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range...............................................................................-10°C...+55°C
Maximum humidity.......................................................................................................... 93±3%
Dimensions ......................................................................................................38 x 78 x 16 mm
Weight................................................................................................................................. 30 g