3.0 Application :
Installation Method : Horizontal installation ONLY
Flow Direction : One way
Flow Rate : 0.2 – 5 liter/min
0° 30°30°
Max. M3x10mm
4.0 General :
Temperature : 0 to 80 (32 to℃170 )℉
Pressure : Max. 8 bar (113 psi)
Weight : 140 g (5.38 oz)
Accuracy : +/- 5 %
Connection : 1/4” BSP male
Materials : Sensor Body : PA66 with 50% glass fiber, Grivory GV-5H
Paddle : Acetal Copolymer, TICONA M90
Stick of Turbine : #304 Stainless Steel
O-Ring : EPDM Rubber
Housing : ABS resin
5.0 Operation Guide
5.1 Connecting power
The operating voltage of the DigiFlow 6710M-32TM is 3V DC. Connecting the power cord with proper
power adapter or battery pack.
5.2 Connecting Fitting
The specification of the DigiFlow 6710M-32TM connection is 1/4” BSP male. You could use any 1/4” BSP
male connectors.
5.3 Operating
The DigiFlow 6710M-32TM automatically turns on the screen when there is water flowing through the
sensor. It automatically turns off the screen in 10 seconds when there is no water flowing.