Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Check the pack and make sure you have all the parts listed.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the connections.
This product is suitable for indoor use only.
This product contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distance between the Junction box and the
light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from
areas where they may be at risk from being cut, trapped or damaged.
The mains supply cable must have a minimum cross sectional area of 1.0mm2.
Cables in wall must be protected using suitable conduit or plastic
trunking.
This product has special protection against the ingress of moisture.
This product is suitable for use bathroom zone 2 and outside
zones of a bathroom only. Please see diagram on the right.
If this unit is being fitted in zone 1 a room containing a bath or shower,
a 30mA RCD must be used - in accordance with IEE regulations.
Zone 1 Outside zones0.6m
0.6m
2.25m
Zone 2Zone 2
Functions
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry. It is not
suitable for use on highly flammable surfaces (e.g. polystyrene, textiles).
Ensure the wall is capable of holding the weight of the product. Take care to avoid damaging any concealed wiring and pipes.
The correct fixings should be used for brick, cavity walls or plasterboard.
If mounting, note the position of the "This Way Up" label or marked on the back of the product and ensure it is correctly oriented.
Small size mirror has a group of mirror-hanger and wall-hanger only.
• Drill two holes(Dia: 8mm, depth 50mm) on the wall, and the distance between two holes is 26mm.
• Put the dowels into the holes, Screw up wall-hanger on the wall. Ensure the wall-hanger is level.
• Pull the supply cable through the hole in the wall back, and connect the cable to terminal block, ensure correct polarity:
brown cable refer to Live wire(L) and blue Nature wire(N); ------The terminal box is a selective module.
• Get the mirror hang to the wall-hanger that fixed on the wall already. Ensure that the product is level.
• Replace fuse or circuit breaker and switch on. Your light is now ready for use.
This power supply is Double Insulated and does not require connection to an Earth circuit.
Lamp
Button
Demist
Button
Hanger(x 1) Dowel(x 2) Screw(x 2)
Installation accessories:
26mm
Ø8mm
a
b
c
d
e
f
c
1
3 4
2
1. Two buttons. Left is Lamp Button and Right is Demist Button.
2. When the fitting is connected to power first time, the demist function will be on,
and it will automatic turn off after 60 minutes.
3. Lamp Button:
When the light strip is off, there is no backlight on the button.
Touch the lamp button to activate the strip and the lamp button will have white backlight.
Touch the lamp button again to turn on the strip (Default 3000K) and the Lamp button will
have the blue backlight.
Touch the lamp button to change the color temperature (3000K-4000K-6500K-OFF).
Once the strip is off, long press the lamp button to turn off the backlight.
4. Demist Button:
Touch the demist button to turn the demist function on (with blue backlight) and off (with white backlight).
Long press the button to turn the backlight off.