Quick Start Guide – Press Control 3000 – 300 Series Manual Press
PRC3000ManPressQuickStart.doc Page 2 of 4 July 2009
Power up & initialize press
1. Turn control on using green power button.
2. Operate press for “reference stroke”.
Parameter Input Screen
Parameter Input Screen Information (D-In)
•Press Parameter Input Key (D-In)
•Use arrow keys to highlight parameter to change.
•Press enter to change highlighted parameter.
•Use keypad to change value.
•Press enter to accept and esc to abort change.
•Reference Section 5 of Operators manual for details.
Parameter Definitions
Parameter 0 – Select press mode, 0 for force, 1 for stroke and 2 for manual.
Parameter 1 – Target force if force is selected.
Parameter 2 – Target stroke if stroke is selected.
Parameter 3 – Time delay before ram retracts after target is reached.
Parameter 4 – Start & stop position for recording force curve. 5mm is min.
Parameter 5 – Enables/Disables access to change and zero counters.
Parameter 6 – Target count for preset counter.
Parameter 7 – Time alarm sounds for when target quantity is reached.
Parameter 8 – Time alarm sounds for when press error occurs.
0 Mode: F=0, s=1, m=2 1
1 Unlock at target force 100 N
2 Unlock at target stroke 20 mm
3 Unlock target time 0.5 sec
4 Start/Stop PDA 5 mm
5 Counter access 1
6 Target count 10 pcs
7 Alarmtime quan. Reached 3 sec
8 Alarmtime press error 3 sec
9
D-In Key