SchwankAir 3200 Series User manual

schwankgroup.com/schwankair
The air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certied Ratings Program. The AMCA Certied Ratings Seal applies to
airow rate, average outlet velocity, outlet velocity uniformity, velocity projection and power rating at free
delivery only.
Installation Manual
SchwankAir 3200 Series
SchwankAir

schwankgroup.com/schwankair
3 Electrical heat - [IP20]
Model Output
[kW]
Airflow*1
[CFM]
Sound
power*2
[dB[A]]
Sound
Pressure
[dB[A]]
FLA [full load
amperage]*3
[A]
Motor
power
[W]
Amperage
motor
[A]
Voltage [V]
Amperage
[A] [heat]
Weight
[lb]
AC-TE36-20 4/7 1150 73 55 21 135 0.86 208V3~/19 57
AC-TE60-20 7/10 1600 72 54 29 147 0.94 208V3~/28 82
AC-TE72-20 8/13 2250 75 57 39 270 1.71 208V3~/36 112
AC-TE36-48 4/8 1150 73 55 11 135 0.86 480V3~/10 57
AC-TE60-48 6/12 1600 72 54 16 147 0.94 480V3~/15 82
AC-TE72-48 8/16 2250 75 57 21 270 1.71 480V3~/20 112
AC-TE36-60 4/8 1150 73 55 9 135 0.86 600V3~/8 57
AC-TE60-60 6/12 1600 72 54 13 147 0.94 600V3~/12 82
AC-TE72-60 8/16 2250 75 57 17 270 1.71 600V3~/16 112
1 Ambient, no heat - [IP21]
Model Output
[MBH]
Airflow*1
[CFM]
Sound power*2
[dB[A]]
Sound Pressure
[dB[A]]
Motor
power [W]
Voltage
motor [V]
Amperage
motor [A]
Weight [lb]
AC-TA36-23 0 1150 73 55 135 208V~ 0.86 49
AC-TA60-23 0 1600 72 54 147 208V~ 0.94 71
AC-TA72-23 0 2250 75 57 270 208V~ 0.72 93
Model Output*4
[MBH]
Airflow*1
[CFM]
Sound
power*2
[dB[A]]
Sound
Pressure
[dB[A]]
Motor
power
[W]
Voltage
motor
[V]
Amperage
motor
[A]
Water
volume
[US gal]
Weight
[lb]
AC-TW36-23 27 1050 72 54 109 208V~ 0.71 0.34 57
AC-TW60-23 48 1550 72 54 135 208V~ 0.86 0.55 79
AC-TW72-23 65 2150 74 56 218 208V~ 1.42 0.71 106
2 Water heat - [IP21]
1. Highest airow at 3 fan speed.
2. Values shown are for total sound power levels for Installation Type A: free inlet, free outlet.
3. The Sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA
Standard 301.
4. FLA: total amperage for motor and heat.
5. Applicable at water temperature 140/104F, air temperature, in +64F.
Above table is valid for 208V/1ph/60Hz. Also approved for 230V/1ph/60Hz. Product performance for
230V/1ph/60Hz will differ from stated data.
Protection class for units with electrical heating: [TE] IP20.
Protection class for units without electric heating and units with water heating: [TW] IP21.
The air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certied Ratings Program. The AMCA Certied Ratings Seal applies to
airow rate, average outlet velocity, outlet velocity uniformity, velocity projection and power rating at free
delivery only.
Technical Specification

schwankgroup.com/schwankair
1. Recommended outlet air temperature for good comfort and optimized output.
2. Nominal output at given supply and return water temperature.
Model Nozzle
width x depth [in]
Max Velocity
at nozzle [fpm]
Outlet Velocity
[fpm]
Outlet Velocity
Uniformity [%]
AC-TA36-23 38.4x2.6 2346 1974 81
AC-TE36-20[48][60] 38.4x2.6 2346 1974 81
AC-TA60-23 58.5x2.6 2267 1860 80
AC-TE60-20[48][60] 58.5x2.6 2267 1860 80
AC-TA72-23 77.8X2.6 2346 1974 81
AC-TE72-20[48][60] 77.8X2.6 2346 1974 81
AC-TW36-23 38.4x2.6 2165 1785 75
AC-TW60-23 58.5x2.6 1791 1545 82
AC-TW72-23 77.8X2.6 2165 1785 75
Model Fan
Speed
Airflow
[CFM]
Output
[MBH]
Return water
temp. [°F]
Water flow
[GPM]
Pressure
drop [kPa]
Output*2
[MBH]
Outlet air
temp. [°F]
Water
flow [GPM]
Pressure
drop [kPa]
AC-TW36-23 max 1050 34.1 108 1.0 1.4 50.9 108 2.9 8.8
AC-TW60-23 max 1550 52.2 100 1.4 2.0 82.6 113 4.7 16.2
AC-TW72-23 max 2150 72.4 100 1.9 2.6 114.0 111 6.5 21.6
Technical Specification
Supply water temperature: 176 °F
Room temperature: +64 °F
Outlet air temperature: +95 °F*1
Water temperature: 176/140 °F
Room temperature: +64 °F
Model Fan
Speed
Airflow
[CFM]
Output
[MBH]
Return water
temp. [°F]
Water flow
[GPM]
Pressure
drop [kPa]
Output*2
[MBH]
Outlet air
temp. [°F]
Water flow
[GPM]
Pressure
drop [kPa]
AC-TW36-23 max 1050 34.8 118 3.1 10.9 28.0 90 1.6 3.2
AC-TW60-23 max 1550 49.8 108 3.2 8.7 46.4 91 2.6 6.1
AC-TW72-23 max 2150 73.7 113 5.5 17.2 64.5 91 3.6 8.1
Supply water temperature: 140 °F
Room temperature: +64 °F
Outlet air temperature: +95 °F*1
Water temperature: 140/104 °F
Room temperature: +64 °F

schwankgroup.com/schwankair
The introduction pages consist mainly of pictures.
For translation of the English texts used, see the respective language pages.
EN
Les pages de présentation contiennent principalement des images.
Pour la traduction des textes en anglais, consultez la page correspondante à la
langue souhaitée.
FR

schwankgroup.com/schwankair
Valve (3/4
")
Valve (3/4
")
G
L
M
K
JO
G
Valve (3/4
")
Valve (3/4
")
E / C / A
GKN
RH
QI
P
JO
F / D / B Valve [3/4"],
outside thread
L = 6.6 ft
A/W
Valve (3/4
")
Valve (3/4
")
L KG G E
Ref [inch] Model
A81.40 AC-TA72-23
AC-TE72-20[48][60]
AC-TW72-23
B80.5 AC-TA72-23
AC-TE72-20[48][60]
AC-TW72-23
C62.1 AC-TA60-23
AC-TE60-20[48][60]
AC-TW60-23
Ref [inch] Model
P2 All Models
Q1.65 All Models
R0.39 All Models
Ref [inch] Model
D61.2 AC-TA60-23
AC-TE60-20[48][60]
AC-TW60-23
E42 AC-TA36-23
AC-TE36-20[48][60]
AC-TW36-23
F41.1 AC-TA36-23
AC-TE36-20[48][60]
AC-TW36-23
Ref [inch] Model
G81.40 All Models
H18 All Models
I10 All Models
J8.22 All Models
K6.57 All Models
L6.49 All Models
M4.68 All Models
N8.22 All Models
O1.96 All Models
Dimensions

schwankgroup.com/schwankair
A B
Gland
Knock-out
Knock-out
ø17,5 ø17,5
ø32,5
ø25,5
ø20,5
ø17,5
Gland Gland
A A
B
C
D
Fig. 2
Knock-out A
Open the unit
Ref [inch]
A0.69
B0.81
C1.00
D1.28

schwankgroup.com/schwankair
Fig. 3: Open the unit.
C
Fig. 4
Fig. 5
min 60
1.18 in
2.36 in
2.36 in
Minimum distance

schwankgroup.com/schwankair
Fig. 6: Mounting with wall brackets
D
B C
min 500 mm
36" Models 2 pcs
60" Models 2 pcs
72" Models 3 pcs
A
20
Ø8 (3x)
Ø7
Ø16
213
37
260
75 35
Ref [inch]
A10.24
B1.46
C8.39
D2.95
E1.38
F0.79
G0.31
H0.28
I0.63
min 19.7 in
A
G [x3]
H
I
B
C
DEF
Mounting with wall brackets

schwankgroup.com/schwankair
JC-0702-15/20JC-0754-15/20 JC-0704-15/20
Accessories
JC-0752-XX
Water Heated Plumbing Kit
Nipple
JC-0754-15/20 - Threaded Rods for Ceiling Mount [3.4ft]
JC-0702-15/20 - Pendulum Ceiling Bars
JC-0704-15/20 - Pendulum Ceiling Brackets
JC-0752-XX - 3/4 Plumbing Kit for Water Heated Models
Kit includes:
•Valve kit: TAC, pressure independent regulation
and adjustment valve + shut off valve
•Nipple connection for valve, female thread [x2]
•Actuator ON/OFF 230V
•Bypass valve

schwankgroup.com/schwankair
5A x 3
N H1H2
N
1
On
Off
F1 F2 F3
on/off 2
N
LPE N L
PE
~
6 5 4 2 31 ALPE N
S E NS OR
208V1~
0 -10V
Only water
N L
1L EP
L2
L3
N
L
1L EP
3L 2L
Blue
Yellow
R ed
White
M
~
M
~~ ~
Left motor Right motor
6 5 4 2 31 ALPE N
Red /+10 V
Yellow / 0-10
Blue /GND
White /Tach
0 - 10V
DOOR
AFT E R
WAT E R
5A
16A
EP 2L1L
Only 72” version
Wiring Diagram - SchwankAir 3200 Series
Ambient & Water Heated

schwankgroup.com/schwankair
L1
L2
L3
L3
L1
L2
Over heat
cut-out
°C
N H1H2
N
1
On
Off
F 1 F2 F 3
2
N
L
0 - 10V
DOOR
AFT ER
WAT ER
PE N L
PE
~
C1
L1
L2
L3
L3
L1
L2
C2
L3
L2
L1
a1
a2
b2
c2
c1
b1
L3
L2
L1
a1
a2
b2
c2
c1
b1
°C
Over heat
cut-out
L1
L2
L3
L3
L1
L2
C3
L1
L2
L3
L3
L1
L2
C4
L3
L2
L1
a1
a2
b2
c2
c1
b1
L3
L2
L1
a1
a2
b2
c2
c1
b1
208V3~
0 -10V
6 5 4 2 31 ALPE N
M
~
M
~~ ~
Left motor Ri ght motor
6542 31 A
LPE N
Blue
Yellow
Red
White
R ed/ +10 V
Yellow / 0-10
B lue / GND
White / Tach
Only 72" Electric
Heated 208V Models
5A x 3
5A
16A
on/off
S ENSOR
1L EP
L2
L3
Wiring Diagram - SchwankAir 3200 Series
Electric Heated 208V

schwankgroup.com/schwankair
Transformer 600V/480V - 230V
L1
L2
L3
Over heat
cut-out
°C
N H1H2
N
1
On
Off
F1 F2 F3
2
N
L
0 - 10V
DOOR
AFT E R
WATE R
PE N L
PE
~
C1
L1
L2
L3
C2
°C
Over heat
cut-out
L1
L2
L3
C3
L1
L2
L3
C4
0 -10V
1L EP
3L 2L
6 5 4 2 31 ALPE N
M
~
M
~~ ~
Left motor Right motor
6 5 4 2 31 ALPE N
B lue
Y el low
R ed
White
Red/ +10 V
Yellow / 0-10
B lue / GND
White/ Tach
Only 72" Electric
Heated 480/600V Models"
5A x 3
5A
16A
on/off
S E NS OR
600V3~/480V3~
2 x 10AFUS E
Wiring Diagram - SchwankAir 3200 Series
Electric Heated 480V/600V

SchwankAir 3200 Series - Ambient
Item Description Part # Model #
90 3200 Air Curtain Front Cover 36” [Surface] JC-0501-10 AC-TA36-23
3200 Air Curtain Front Cover 60” [Surface] JC-0501-15 AC-TA60-23
3200 Air Curtain Front Cover 72” [Surface] JC-0501-20 AC-TA72-23
50 3200 Air Curtain Impellor-R 36” & 72” [Surface & Recessed] JC-0502-10 AC-TA36-23
3200 Air Curtain Impellor-R 60” [Surface & Recessed] JC-0502-15 AC-TA60-23
45 3200 Air Curtain Impellor-L 60” & 72” [Surface & Recessed] JC-0502-20 AC-TA72-23
40 3200 Air Curtain EC Motor Left 72” JC-0503-20 AC-TA72-23
35 3200 Air Curtain EC Motor Right 36” JC-0503-10 AC-TA36-23
3200 Air Curtain EC Motor 60” JC-0503-15 AC-TA60-23
30 3200 Air Curtain Nozzle Grill 36” JC-0504-10 AC-TA36-23
3200 Air Curtain Nozzle Grill 60” JC-0504-15 AC-TA60-23
3200 Air Curtain Nozzle Grill 72” JC-0504-20 AC-TA72-23
25 3200 Air Curtain Nozzle Bracket JC-0505-XX AC-TA36-23
AC-TA60-23
AC-TA72-23
20 3200 Series Internal Sensor JC-0506-XX AC-TA36-23
AC-TA60-23
AC-TA72-23
15 3200 Air Curtain PCB. JC-0507-XX AC-TA36-23
AC-TA60-23
AC-TA72-23
schwankgroup.com/schwankair
Replacement parts list

10 3200 Air Curtain Left Cover JC-0508-XX AC-TA36-23
AC-TA60-23
AC-TA72-23
5 3200 Air Curtain Right Cover JC-0509-XX AC-TA36-23
AC-TA60-23
AC-TA72-23
schwankgroup.com/schwankair

schwankgroup.com/schwankair
Item Description Part # Model #
90 3200 Air Curtain Front Cover 36” [Surface] JC-0501-10 AC-TE36-20
AC-TE36-48
AC-TE36-60
3200 Air Curtain Front Cover 60” [Surface] JC-0501-15 AC-TE60-20
AC-TE60-48
AC-TE60-60
3200 Air Curtain Front Cover 72” [Surface] JC-0501-20 AC-TE72-20
AC-TE72-48
AC-TE72-60
50 3200 Air Curtain Impellor-R 36” & 72” [Surface & Recessed] JC-0502-10 AC-TE36-20
AC-TE36-48
AC-TE36-60
3200 Air Curtain Impellor-R 60” [Surface & Recessed] JC-0502-15 AC-TE60-20
AC-TE60-48
AC-TE60-60
45 3200 Air Curtain Impellor-L 60” & 72” [Surface & Recessed] JC-0502-20 AC-TE72-20
AC-TE72-48
AC-TE72-60
SchwankAir 3200 Series - Electric
Replacement parts list

40 3200 Air Curtain EC Motor Left 72” JC-0503-20 AC-TE72-20
AC-TE72-48
AC-TE72-60
35 3200 Air Curtain EC Motor Right 36” JC-0503-10 AC-TE36-20
AC-TE36-48
AC-TE36-60
3200 Air Curtain EC Motor 60” JC-0503-15 AC-TE60-20
AC-TE60-48
AC-TE60-60
30 3200 Air Curtain Nozzle Grill 36” JC-0504-10 AC-TE36-20
AC-TE36-48
AC-TE36-60
3200 Air Curtain Nozzle Grill 60” JC-0504-15 AC-TE60-20
AC-TE60-48
AC-TE60-60
3200 Air Curtain Nozzle Grill 72” JC-0504-20 AC-TE72-20
AC-TE72-48
AC-TE72-60
25 3200 Air Curtain Nozzle Bracket JC-0505-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
20 3200 Series Internal Sensor JC-0506-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
15 3200 Air Curtain PCB. JC-0507-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
schwankgroup.com/schwankair

AC-TE72-60
10 3200 Air Curtain Left Cover JC-0508-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
5 3200 Air Curtain Right Cover JC-0509-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
22 3200 Air Curtain Transformer JC-0521-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
70 3200 Air Curtain Heating Rod - 347V 36” Back JC-0522-XX AC-TE36-48
3200 Air Curtain Heating Rod - 347V 36” Back JC-0522-XX AC-TE36-60
3200 Air Curtain Heating Rod - 347V 36” Front JC-0523-XX AC-TE36-48
3200 Air Curtain Heating Rod - 347V 36” Front JC-0523-XX AC-TE36-60
3200 Air Curtain Heating Rod - 347V 60” Back JC-0524-XX AC-TE60-48
3200 Air Curtain Heating Rod - 347V 60” Back JC-0524-XX AC-TE60-60
3200 Air Curtain Heating Rod - 347V 60” Front JC-0525-XX AC-TE60-48
3200 Air Curtain Heating Rod - 347V 60” Front JC-0525-XX AC-TE60-60
3200 Air Curtain Heating Rod - 208V 36” Front JC-0526-XX AC-TE36-20
3200 Air Curtain Heating Rod - 208V 60” Front JC-0527-XX AC-TE60-20
3200 Air Curtain Heating Rod - 208V 60” Back JC-0528-XX AC-TE72-20
65 Air Curtain Thermal Cut-Off Electric Heated JC-0529-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
schwankgroup.com/schwankair

AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
60 3200 Air Curtain Contactor Electric Heated JC-0530-XX AC-TE36-20
AC-TE36-48
AC-TE36-60
AC-TE60-20
AC-TE60-48
AC-TE60-60
AC-TE72-20
AC-TE72-48
AC-TE72-60
schwankgroup.com/schwankair

SchwankAir 3200 Series - Hot Water
Item Description Part # Model #
90 3200 Air Curtain Front Cover 36” [Surface] JC-0501-10 AC-TW36-23
3200 Air Curtain Front Cover 60” [Surface] JC-0501-15 AC-TW60-23
3200 Air Curtain Front Cover 72” [Surface] JC-0501-20 AC-TW72-23
50 3200 Air Curtain Impellor-R 36” & 72” [Surface & Recessed] JC-0502-10 AC-TW36-23
3200 Air Curtain Impellor-R 60” [Surface & Recessed] JC-0502-15 AC-TW60-23
45 3200 Air Curtain Impellor-L 60” & 72” [Surface & Recessed] JC-0502-20 AC-TW72-23
40 3200 Air Curtain EC Motor Left 72” JC-0503-20 AC-TW72-23
35 3200 Air Curtain EC Motor Right 36” JC-0503-10 AC-TW36-23
3200 Air Curtain EC Motor 60” JC-0503-15 AC-TW60-23
30 3200 Air Curtain Nozzle Grill 36” JC-0504-10 AC-TW36-23
3200 Air Curtain Nozzle Grill 60” JC-0504-15 AC-TW60-23
3200 Air Curtain Nozzle Grill 72” JC-0504-20 AC-TW72-23
25 3200 Air Curtain Nozzle Bracket JC-0505-XX AC-TW36-23
AC-TW60-23
AC-TW72-23
schwankgroup.com/schwankair
Replacement parts list

20 3200 Series Internal Sensor JC-0506-XX AC-TW36-23
AC-TW60-23
AC-TW72-23
15 3200 Air Curtain PCB. JC-0507-XX AC-TW36-23
AC-TW60-23
AC-TW72-23
10 3200 Air Curtain Left Cover JC-0508-XX AC-TW36-23
AC-TW60-23
AC-TW72-23
5 3200 Air Curtain Right Cover JC-0509-XX AC-TW36-23
AC-TW60-23
AC-TW72-23
85 3200 Air Curtain Water Filter Holder JC-0540-XX AC-TW36-23
AC-TW60-23
AC-TW72-23
80 3200 Air Curtain Coil Filter 36” [Surface & Recessed] JC-0541-10 AC-TW36-23
3200 Air Curtain Coil Filter 72” [Surface & Recessed] JC-0541-15 AC-TW60-23
3200 Air Curtain Coil Filter 60” [Surface & Recessed] JC-0541-20 AC-TW72-23
75 3200 Air Curtain Water Coil 36” [Surface] JC-0542-10 AC-TW36-23
3200 Air Curtain Water Coil 60” [Surface] JC-0542-15 AC-TW60-23
3200 Air Curtain Water Coil 72” [Surface] JC-0542-20 AC-TW72-23
schwankgroup.com/schwankair
This manual suits for next models
15
Table of contents
Other SchwankAir Heater manuals
Popular Heater manuals by other brands

Qlima
Qlima PEW 3020 operating manual

Creda
Creda CAR 033 Operating instructions manual

Detroit Radiant Products
Detroit Radiant Products AVS Series installation manual

Valley Comfort Systems
Valley Comfort Systems VC95C Installation and operation manual

BEHA
BEHA EDP Mounting instructions

Smith's Heating First
Smith's Heating First ECOVECTOR LL 1200 Installation & user guide