manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Scientific Industries
  6. •
  7. Laboratory Equipment
  8. •
  9. Scientific Industries Vortex-Genie 2 Series User manual

Scientific Industries Vortex-Genie 2 Series User manual

U.S.Pat. 4,781,487; 5,707,861
80 Orville Drive, Suite 102, Bohemia, NY 11716 U.S.A.
(631) 567-4700 • Fax: (631) 567-5896 • Toll Free: 888-850-6208
Customer Service: [email protected]
www.scientificindustries.com
APPLICATIONS
The 3-inch Platform accepts single or multiple test tubes,
beakers and various flasks. The removable cover, made
of thermoplastic rubber, is highly impervious to chemicals.
It is, however recommended that spills are blotted quickly.
Do not attempt to use the 3-inch Platform without the rub-
ber cover.
The Pop-off Cup can accommodate tubes of virtually any
size or shape from micro tubes to those up to 40mm in
diameter and 200mm in length. In most instances, tubes
without caps may be mixed with proper speed control.
Tubes must be capped when potential aerosols may be
hazardous.
Catalog numbers:
0K-0500-902 3-inch Platform with Rubber Cover
0K-0500-901 3-inch Platform without Rubber Cover
580-2013-00 Rubber Cover for 3-inch Platform
OPERATING INSTRUCTIONS
We recommend you retain the original packaging for 90
days in case you need to return the product for any reason
to your distributor or Scientific Industries.
Your VORTEX-GENIE 2 Mixer is supplied with a Pop-off
Cup located in the white foam box insert and a 3-inch
Platform. After you unpack your VORTEX-GENIE 2 Mixer
from its protective plastic bag, install either the Pop-off Cup
or the 3-inch Platform by first aligning the "flat" part of the mixer shaft with the "flat"
part of the attachment. YOU MUST PRESS DOWN HARD WITH YOUR HAND
UNTIL YOU HEAR THE ATTACHMENT SNAP IN PLACE. This will ensure that the
attachment will not come off the mixer during operation.
1.0 - Plug the cord into a properly grounded, three pronged outlet (120 VAC for
the G560 model, 230 VAC for the G560E model and 100V for the G560-
100V model).
2.0 - The VORTEX-GENIE®2 Mixer has the following modes of operation:
2.1 - TOUCH MODE:
Place the toggle switch in the TOUCH position and set the speed control to any
position between 3 and 10. A setting of 3 is least vigorous mixing and 10 is the
most vigorous mixing. When you touch a vessel to the 3-inch Platform or Pop-
off Cup, the mixer will start automatically. Releasing the pressure on the
Platform or Cup will stop the mixer.
2.2 - HANDS FREE MODE:
Place the toggle switch in the ON position and set the speed control to any
position between 3 and 10. Hands Free mode allows for unattended operation
that will continue indefinitely until you stop the mixer by placing the toggle
switch into the OFF position. In this mode, you may use any of the accessory
attachments available for the VORTEX-GENIE®2 Mixer. Review instruction
No. 3.0 before attempting to change attachments.
Note: The speed control switch should be set between positions 3 and 10 to
enable the mixing action to start. After the action has started, you may, if
desired, reduce the speed below position 3 for the duration of the run.
Before re-starting the mixer, re-set the speed control to a setting higher than
position 3.
3.0- To change accessory mixing attachments, the following sequence is to be
followed explicitly.
3.1 - Turn the power OFF by placing the toggle switch into the OFF position.
3.2- Grasp the installed attachment and pull straight up until it releases from the
shaft. A technique of lifting the attachment with your finger tips while using
your knuckles as a fulcrum will give you the leverage to remove the installed
attachment component smoothly.
3.3- Hold the part you wish to install so the "flat" part of the shaft is aligned with
the "flat" of the receptacle in the attachment. Alternatively, you may place the
attachment on the shaft and turn it until you feel the "flats" aligning.
3.4- Press attachment firmly downward until it "snaps" into place. The VORTEX-
GENIE 2 Mixer is now ready to use with the newly installed accessory
attachment.
4.0- With prolonged use, your VORTEX-GENIE 2 Mixer may become warm to the
touch. The motor will radiate a certain amount of heat that will dissipate by the
cast zinc housing.
CAUTION! Do not lift your VORTEX-GENIE 2 Mixer by its attachment. All
attachments, including the Pop-off Cup and the 3-inch Platform are removable.
They will pop off easily if you lift them, and snap back on again just as easily
by aligning the flats and pressing down firmly.
CAUTION! If this equipment is used in a manner not specified by the man-
ufacturer, the protection provided by the equipment may be impaired.
CARE AND HANDLING
Your VORTEX-GENIE 2 Mixer should be given the care normally required for any
electrical appliance. Avoid wetting or unnecessary exposure to fumes. The finish can
be washed with water (after unplugging) and soap or detergents, using a cloth or
sponge. Keep the unit clean by immediately blotting any spills. Replacement parts
are available through most laboratory equipment distributors or directly from Scientific
Industries. Refer to "Parts Assembly List" and enclosed multi-fold brochure.
CAUTION! Unplug from power before cleaning. Do not immerse. Do not
position the equipment so that it is difficult to disconnect the power cord.
Vortex-Genie®Scientific Industries
© Scientific Industries Inc. 2015 065-0004-00 Rev. X
Indicator No. Part No. Description Indicator No. Part No. Description
1 580-2013-00 Rubber Cover for 3-inch Platform 9 0K-0236-408 Bottom Closure with Feet Kit
2 0K-0500-901 3-inch Platform 10 0M-0236-209 Knob, Push-on
3 146-3011-00 Pop-off Cup 11 ESP0004 Switch, On/Off/On
4 0K-0236-902 Bearing Retainer Kit 12A 318-0510-02 120V Line Cord
5 566-0028-00 Spring, Extension, Eccentric 12B 0K-0246-901 230V Line Cord, No Plug
6A 0K-0236-905 Motor 120V Assembly 12C 0K-0256-901 230V Line Cord, Euro Plug
6B 0K-0246-915 Motor 230V Assembly 12D 0K-0266-901 230V Line Cord, British Plug
6C 0K-0286-915 Motor 100V Assembly 12E 0K-0276-901 230V Line Cord, Swiss Plug
7 ESP0005 Micro Switch 12F 0K-0286-901 100V Line Cord
8A EPP0005 Speed Control 120V 12G ECP0021 Australian Plug (only)
8B EB-0246-500 Speed Control 240V
8C EB-0286-500 Speed Control 100V
SPECIFICATIONS
The VORTEX-GENIE 2 Mixer is classified as "Installation Category 2", “Overvoltage
Category 2”, and “Pollution Degree 2”.
Environmental: 0°C - 38°C (32°F - 100°F), 95% Humidity max. Indoor use only in
elevation up to 2000m of altitude.
MODE POWER REQUIRED HZ AMPS
G560 120V 60 0.65
G560E 230V 50 0.5
G560-100V 100V 50 1.0
Weight: 4 Kg (8.8 lb)
Base Dimensions: (DxWxH) 165x122x165mm (6.5x4.8x6.5in)
PARTS ASSEMBLY LIST
To order parts for the VORTEX-GENIE 2 Mixer:
Contact your local distributor or visit www.scientificindustries.com. Please specify
Part No., quantity and electric voltage.

This manual suits for next models

3

Other Scientific Industries Laboratory Equipment manuals

Scientific Industries MULTI VORTEX-GENIE SI-M236 User manual

Scientific Industries

Scientific Industries MULTI VORTEX-GENIE SI-M236 User manual

Scientific Industries ENVIRO-GENIE Series User manual

Scientific Industries

Scientific Industries ENVIRO-GENIE Series User manual

Scientific Industries MULTIPLATE GENIE SI-4100 User manual

Scientific Industries

Scientific Industries MULTIPLATE GENIE SI-4100 User manual

Scientific Industries ROTATOR GENIE SI-2100 User manual

Scientific Industries

Scientific Industries ROTATOR GENIE SI-2100 User manual

Scientific Industries Enviro-Genie User manual

Scientific Industries

Scientific Industries Enviro-Genie User manual

Popular Laboratory Equipment manuals by other brands

Stuart Microcentrifuge 8500 Operator's manual

Stuart

Stuart Microcentrifuge 8500 Operator's manual

Oxford Instruments Andor Marana-X-11 quick start guide

Oxford Instruments

Oxford Instruments Andor Marana-X-11 quick start guide

BTX AgilePulse ID user manual

BTX

BTX AgilePulse ID user manual

CERUS INTERCEPT INT100 Operator's manual

CERUS

CERUS INTERCEPT INT100 Operator's manual

Tektronix Option 10 Service manual

Tektronix

Tektronix Option 10 Service manual

Heidolph Hei-TORQUE Expert operating instructions

Heidolph

Heidolph Hei-TORQUE Expert operating instructions

Endress+Hauser Levelflex FMP51 Safety instructions

Endress+Hauser

Endress+Hauser Levelflex FMP51 Safety instructions

vacuubrand VAC 24 SEVEn Instructions for use

vacuubrand

vacuubrand VAC 24 SEVEn Instructions for use

Benchmark Orbi-Shaker Operation manual

Benchmark

Benchmark Orbi-Shaker Operation manual

SCIEX ZenoTOF 7600 System user's guide

SCIEX

SCIEX ZenoTOF 7600 System user's guide

Human HumaRoll user manual

Human

Human HumaRoll user manual

Benchmark MyBath B2000-2 instruction manual

Benchmark

Benchmark MyBath B2000-2 instruction manual

Asymptote VIA Freeze Series user manual

Asymptote

Asymptote VIA Freeze Series user manual

Thermo 1284 Operating and maintenance manual

Thermo

Thermo 1284 Operating and maintenance manual

DrBrowns AC045-INTL Instructions for use

DrBrowns

DrBrowns AC045-INTL Instructions for use

SCHOTT KL 1500 HAL user manual

SCHOTT

SCHOTT KL 1500 HAL user manual

Essilor SL500L installation manual

Essilor

Essilor SL500L installation manual

Mopec BK200 user manual

Mopec

Mopec BK200 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.