SCIEX P/ACE MDQ Plus Technical manual

P/ACE®MDQ Plus Capillary
Electrophoresis System
Site Planning Guide
October 2018RUO-IDV-01-4899-A | B54950 AB

This document is provided to customers who have purchased SCIEX equipment to use in the operation of such SCIEX
equipment. This document is copyright protected and any reproduction of this document or any part of this document is
strictly prohibited, except as SCIEX may authorize in writing.
Software that may be described in this document is furnished under a license agreement. It is against the law to copy, modify,
or distribute the software on any medium, except as specifically allowed in the license agreement. Furthermore, the license
agreement may prohibit the software from being disassembled, reverse engineered, or decompiled for any purpose. Warranties
are as stated therein.
Portions of this document may make reference to other manufacturers and/or their products, which may contain parts whose
names are registered as trademarks and/or function as trademarks of their respective owners. Any such use is intended only
to designate those manufacturers' products as supplied by SCIEX for incorporation into its equipment and does not imply
any right and/or license to use or permit others to use such manufacturers' and/or their product names as trademarks.
SCIEX warranties are limited to those express warranties provided at the time of sale or license of its products and are SCIEX’s
sole and exclusive representations, warranties, and obligations. SCIEX makes no other warranty of any kind whatsoever,
expressed or implied, including without limitation, warranties of merchantability or fitness for a particular purpose, whether
arising from a statute or otherwise in law or from a course of dealing or usage of trade, all of which are expressly disclaimed,
and assumes no responsibility or contingent liability, including indirect or consequential damages, for any use by the purchaser
or for any adverse circumstances arising therefrom.
For research use only. Not for use in diagnostic procedures.
AB Sciex is doing business as SCIEX.
The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners.
AB SCIEX™is being used under license.
©2018 AB Sciex
AB Sciex LLC
500 Old Connecticut Path
Framingham, Massachusetts 01701
USA
Site Planning GuideP/ACE®MDQ Plus Capillary
Electrophoresis System
RUO-IDV-01-4899-A | B54950 AB2 / 18

1 Introduction..............................................................................................................................................5
Customer Site Planner Responsibilities..............................................................................................................................5
FSE Responsibilities............................................................................................................................................................6
During Installation.......................................................................................................................................................6
Customer Familiarization.............................................................................................................................................6
Technical Support..............................................................................................................................................................6
2 Site Planning Checklist.............................................................................................................................7
Customer Information........................................................................................................................................................7
Requirements.....................................................................................................................................................................7
Site Layout...................................................................................................................................................................7
Electrical Requirements................................................................................................................................................8
Ventilation and Waste Collection Requirements..........................................................................................................8
Environmental Requirements.......................................................................................................................................9
Computer, Network, and Software Requirements........................................................................................................9
Solutions and Equipment Requirements......................................................................................................................9
Customer Preparation..................................................................................................................................................9
Customer Profile..............................................................................................................................................................10
Comments and Exceptions...............................................................................................................................................11
Signoff.............................................................................................................................................................................11
A Site Requirements.................................................................................................................................12
Site Layout Requirements................................................................................................................................................12
Laboratory Layout and Clearances.............................................................................................................................12
Weights and Dimensions...........................................................................................................................................13
Electrical Requirements....................................................................................................................................................14
Mains Supply Connections.........................................................................................................................................14
Mains Supply Fluctuations.........................................................................................................................................14
Protective Earth Conductor........................................................................................................................................14
System Electrical Specifications..................................................................................................................................14
Ventilation and Waste Collection Requirements..............................................................................................................15
Environmental Requirements...........................................................................................................................................15
BioSafety Requirements.............................................................................................................................................16
Computer, Software, and Network Requirements............................................................................................................16
Controller Requirements............................................................................................................................................16
Printer Requirements.................................................................................................................................................16
LAN Connection (Optional)........................................................................................................................................16
Customer-Supplied Solutions and Equipment..................................................................................................................16
Customer Preparation Requirements...............................................................................................................................17
P/ACE®MDQ Plus Capillary
Electrophoresis System
Site Planning Guide
3 / 18RUO-IDV-01-4899-A | B54950 AB
Contents

This guide is for the site planner, the individual responsible for preparing the facility for the installation of the
system.
Note: For safety and regulatory information, refer to the System Overview Guide.
Customer Site Planner Responsibilities
Complete the Site Planning Checklist on page 7 in consultation with facilities services personnel (electrical,
ventilation, and information technology [IT]), and return it to the SCIEX field service employee (FSE) before the
completion date. Refer to Signoff on page 11.
Note: The FSE will follow up if the checklist is not received prior to the scheduled installation date.
•Verify that adequate space and the required shipping or receiving facilities are available. Refer to Site Layout
Requirements on page 12.
•Provide all required electrical receptacles. Refer to Electrical Requirements on page 14.
•Verify that the requirements for ventilation and waste collection are met. Refer to Ventilation and Waste
Collection Requirements on page 8.
•Verify that the requirements for the operating environment are met. Refer to Environmental Requirements on
page 15.
•Verify that the requirements for the computer and network are met. Refer to Computer, Software, and Network
Requirements on page 16.
•Verify that all required solutions and laboratory supplies are available. Refer to Customer-Supplied Solutions
and Equipment on page 16.
•Verify that up to two operators have been identified for training. Refer to Customer Preparation Requirements
on page 17.
•When the shipment arrives, inspect the packaging exterior for damage. If there is any damage, then note any
issues on the delivery receipt and notify SCIEX immediately.
•Contact SCIEX Customer Service or the local FSE to schedule the installation.
P/ACE®MDQ Plus Capillary
Electrophoresis System
Site Planning Guide
5 / 18RUO-IDV-01-4899-A | B54950 AB
1
Introduction
Other manuals for P/ACE MDQ Plus
2
Table of contents
Other SCIEX Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual