2
7. Reinsert the display PCB assembly into the front of the console.
8. Reinstall the two, outer countersunk screws in the back of the plastic
console.
9. Reconnect all cables to the display PCB.
•When looking at the back of the display PCB, the telco cables plug
in along the left edge. The 6-pin plugs into the top plug and the 8-
pin plugs into the bottom plug.
•If your unit has Cardio Key, the cable plugs into the serial port,
which is the 4-pin Molex header lower right corner.
•If your unit has Broadcast Vision, Cardio Theater, etc., the cable
connects to the 8-pin header located at the bottom center of the
display PCB.
10.Place the display assembly back onto the mounting plate and install the
four display screws.
11.The model of machine must be defined. (You must rotate the cranks to
power up the upper display to perform this next procedure.) When the
display lights up, see if “ELLIPTICAL” appears in the top window. If so,
press the UP arrow one time to display “PRO”. Once “PRO” is displayed,
press ENTER to save. If no unit type appears in the top window upon
power up, the display has probably been preset at the factory. To verify
this, hold the SCAN, SELECT, and PAUSE for three seconds until a type
of machine appears, then release. Do not continue to hold keys once
the type of unit appears. If “PRO” appears in the top window, press
ENTER to save and exit, unless the unit is equipped with Cardio Key. If
“PRO” doesn’t appear in the top window, press and hold SELECT and the
UP or DOWN arrow until “PRO” does appears. For units with Cardio Key,
when “PRO” appears, press ENTER sixteen times until the top window
shows either “C-SAFE COMM” or “CARDIO KEY”. If “CARDIO KEY” is
displayed, press ENTER three times to exit the mode. If this screen
shows “C-SAFE COMM”, press the UP or DOWN arrow to display
“CARDIO KEY” in the top window, then press ENTER three times to exit
the mode.