13
Dailypre‐cautions
Topreventtheaccumulationonthe
icecubesofundesirablebatteriesitis
necessarytoobservethefollowing
indications.
Donotstoreanythingintheice
storagebin.Donotstoreexplosive
substancessuchasaerosolcanswith
flammablepropellantinthisappliance.
Keepicescoopcleananddisinfected.
Duringthecleaningofthefloornear
themachinepayattentionthatdust
doesnotgetsuckedintheunitbythe
fanmotor.
Toavoiddamagetotheunit:
Nevershut‐offthewatersupplywith
themachineinoperation.
Donotplaceontopandaroundtheice
makeranysortofgoods,whichcan
limitproperventilationandjeopardize
hygienicconditions.
Troubleshooting
Beforecontactingtheauthorisedservicecentremake
surethattheexternalswitchandtheon/offbuttonare
ONandthewatercockisopen.
Ifthereisanexternalwatertreatmentdevices,check
thatitisnotobstructed.
Iftheequipmentdoesn'tproduceenoughice,check
andcleantheairfilter.
Alsomakesurethattheambientandinletwater
temperaturesdonotexceedbytoomuchtheones
specifiedatpage4ofthemanual.
Incaseofequipmentmalfunctiontheredalarmbutton
willlightuponthedisplay.
Holdtheredcapacitivealarmbuttonpressedforfive
secondstodisplaythecurrentalarm,thenrefertothe
followingtablelistingthesuggestedsolutions;inany
casealsoinformtheScotsmanservicecentre.
AlarmcodeCauseSolution
A01NowaterOpenthewatercock
A02Evaporatorsensorfailure ContacttheScotsmanservicecentre
A03Condensersensorfailure ContacttheScotsmanservicecentre
A04Waterdispensersensorfailure ContacttheScotsmanservicecentre
A05Icedispensersensorfailure ContacttheScotsmanservicecentre
A06Toohighevaporatortemperature
alarm(>0°C)
ContacttheScotsmanservicecentre
A07Toolowevaporation
temperaturealarm(<‐30°C)
ContacttheScotsmanservicecentre
A08Toohighcondensertemperature
alarm(>70°C)
Airfilterdirtyorambienttemperaturetoohigh.Cleanthefilterandreducetheambient
temperature.IfthealarmoccursagaincontacttheScotsmanservicecentre
A09Toolowcondenser/ambient
temperaturealarm(<3°C)
Warm‐uptheambient,themachinerestartwith5°Cambienttemperature
A10DriveMotoralarm ContacttheScotsmanservicecentre
A11Toohighcondensertemperature
alarmatstart‐up(>55°c)
Airfilterdirtyorambienttemperaturetoohigh.Cleanthefilterandreducetheambient
temperature.IfthealarmoccursagaincontacttheScotsmanservicecentre
A14TESTalarmContacttheScotsmanservicecentre
A15FailureoftheIRprobe
monitoringtheicelevelinthebin
ContacttheScotsmanservicecentre
CLEWatersupplycircuitcleaning
reminder
ContacttheScotsmanservicecentreforthesix‐monthlymaintenance
After5secondsthedisplaywillgooffandonlytheLEDScorrespondingtotheoperatingsettingswillremainon.