Programming - RTS Pg 7
PROGRAMMING RTS
Each RTS Nano shade includes an installation remote that is used to adjust limits and program
group controls. These installation remotes are uniquely numbered to the shade they are paired
with. The lower limit of every shade is preprogrammed to ½” from the bottom of the window.
After installing each shade, follow these steps to adjust the lower limit:
STEP 2 - Assign shades to groups :
Next, program group controls. To pair with a permanent transmitter
such as a multichannel Telis or DecoFlex, follow these steps.
1. Press and hold the program button on the back of the installation
remote until the shade jogs.
2. Select the channel where you want to create a group, then bump
(do not hold down) the program button on the back of the remote -
the shade will jog.
3. Both remotes now control the shade.
4. Continue doing this with each shade until all shades are
programmed in the desired groups.
NOTE: Each RTS motor can be paired with 12 unique transmitters.
PROGRAMMING STEPS (must follow in order)
Step 1: Fine tune lower limit
Step 2: Assign shades to groups
Step 3: Pair groups to control system (Mylink, LinkPro)
1. Beginning with the rst shade, pull plastic tab from remote and press allowing shade to run
to lower limit set at the factory.
2. When shade has stopped, adjust the lower limit by holding and simultaneously until the
shade jogs.
3. Use or to move the shade to the desired lower limit.
4. Hold the “My” button until the shade jogs again.
5. Repeat this procedure at each window until all shades have lower limits set to desired positions.
1. Download the myLink app.
2. Pair the grouped shades with LinkPro or MyLink according to the instructions in the myLink app.
STEP 1 - Fine tuning lower limit :
STEP 3 - Pair Groups to control system (LinkPro, myLink) :
Warning: Do not
attempt to use any
installation remote until all
the shades are installed.
hold the button
until the shade jogs
(light on the motor
turns green).
Installation
Remote
Permanent
Remote
Bump
(do not hold)
WIRING NANO BOX 24V DC RTS
24V DC
For guaranteed motor performance the supplied voltage for 24V motors must be 24V DC. See
the table below for maximum wire lengths.
If the motors are powered using a Power Distribution Enclosure connect the motors to the
“+24V DC” and “-24V DC” ports on the terminal blocks. The RS485 ports are unused.
Wire Gauge (AWG)
14
16
18
Maximum Supported Wire Length (FT.)
250
150
100
V+ Positive 24VDC
V- Negative 24VDC
+24 VDC
-24 VDC
RS 485
RS 485
Only connect to +24V DC and -24V DC
Wiring - Nano Box - 24V DC - RTS Pg 6
Not used