P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-923 Rev G 06-21 Page 4
FACTORY DEFAULTS
Master Programming Code………..………………….….…...123456
Entry Code Length……………………………………….……..4 digits
Request-to-exit Output Relay………………………..........No Output
Alarm Shunt Output….………………………………….........Disabled
Forced Entry Output……………………………..…………No Output
Door Ajar Output…………………………………..…….….No Output
Main Relay On Time…………………………………..…..02 Seconds
Auxiliary Relay On Time…………………………….....…02 Seconds
Solid State Output #3 On Time………………………......02 Seconds
Solid State Output #4 On Time…………………………..02 Seconds
Door Sense/Inhibit Input…………………………...…………...Inhibit
Keypad Lockout Output………………………………..…….Disabled
Keypad Active Output………………………………..…..…..Disabled
Beeper Sounds When Key Pressed……………………...………Yes
Beeper Sounds During Relay #1………………………..…...…….No
Beeper Sounds During Relay #2……………………………...…...No
Beeper Sounds During Output #3……………………………........No
Beeper Sounds During Output #4……………………………........No
Keypad Lockout Count……….………......….3 Tries Before Lockout
Anti-Passback Time………………..……...……….No Anti-Passback
Auto-Relock…………………………………...………….………….On
BASIC PROGRAMMING
When the 923 EntryCheck™ is in Programming Mode the yellow
indicator will blink slowly. After a programming command is
selected, the yellow indicator will flash rapidly while the keypad is
waiting for user input data. The green indicator will light if the data
is accepted. The red indicator will light if any programming data is
entered incorrectly, and the command will have to be fully re-
entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is used
to enter Programming Mode.
Press: # 9 # Master Code #
Master Code = the current 6-digit Master Programming Code
Setting Entry Code Length Default: 4 digits
Press: 03 # Length #
Length = 1-6 for entry code length
Note: If the Entry Code Length is going to be changed from the factory
default of 4 digits, make this change first before programming any entry
codes.
Adding a New PIN Code
Press: 0 1 # Code # Code # Relay #
Code=The new entry code: 1-999999, depending on code length
Relay=Relay output entry code will activate:
1=Main Relay 2=Auxiliary Relay 3=Both Relays
10=Relay #1, toggled 20=Relay #2, toggled 30=both Relays toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled
The green indicator will light momentarily when the new code is
accepted. If the user number already exists or an entry error has
been made, the red indicator will light. Delete the user and re-enter
the new information again.
Note: Leading zeros (zeros before the code number, e.g. 0241) do
not need to be entered when programming a new code. The 923 will
internally add any zeros to fill digits determined by the entry code
length setting. Leading zeros will have to be entered by the user
when entering their code to gain access.
Erasing a Single User
Press: 02 # Code # Code #
Code = The PIN code to be deleted
The yellow indicator will flash quickly while the 923 erases the
user from memory. The green indicator will light when the code is
erased.
Output Toggle Mode
When an output is programmed for Toggle Mode, the output
alternates from OFF to ON or from ON to OFF each time it is
accessed. When an output is toggled on, the green LED remains
solid until toggled off.
The rules for a toggle output are:
If the output is OFF, entering a toggle code will turn ON the
selected relay, and stay on until the next activation of a toggle
code. NOTE: Entering a timed code OR activating the REX input
will not turn off a relay that has been toggled ON.
If the output is ON, entering a toggle code will turn OFF the
selected relay and stay off until the next activation of a toggle
code, timed code, or REX..
Re-entering a Command After a Mistake
If the red indicator lights, signaling an incorrect entry, or an
incorrect key is pressed during programming, to clear the keypad
and re-enter the command:
Press: 9 #
*
Exiting Programming Mode
Press: #
The red indicator will light after exiting Programming Mode
Note: The 923 will automatically exit Programming Mode after 30
seconds of inactivity
**
See the following example that sets entry codes 1234 for normal
operation of the main relay, and 5678 for toggle operation of the
auxiliary relay.
Press: 01 # 1 2 3 4 # 1 2 3 4 # 1 #
01=Add PIN function; 1234=Entry Code; 1=Main Relay
Press: 01 # 5 6 7 8 # 5 6 7 8 # 20 #
01=Add PIN function; 5678=Entry Code; 20=Auxiliary Relay
toggle
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail:
[email protected] ■ 80
1 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Changing the 6-Digit Master Programming Code
Press: 98 # Master Code # Master Code #
Master Code=The new 6-digit Master Programming Code
Once all PIN codes are programmed, it is recommended the
default Master Programming Code be changed using the function
below.
NOTE: You must be in Programming Mode to perform any
function beyond this point.