INSTALLATION AND SAFETY INSTRUCTIONS
FOR YOUR SAFETY
GENERAL
ASSEMBLY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU
ARE WORKING ON IS SHUT OFF; EITHER THE FUSE REMOVED
OR THE CIRCUIT BREAKER SET AT OFF.
You do not need any special tools to install this fixture. Be sure to
follow the steps in the order given. Read instructions carefully.
If you are unclear as to how to proceed, consult a qualified
electrician.
Carefully remove the fixture from the carton and check that all parts
are included, as shown in Figure 1. Be careful not to misplace
any of the screws or parts which are needed to install this fixture.
IF SUPPLY WIRES ARE LOCATED WITHIN 3” OF
BALLAST, USE WIRE RATED FOR AT LEAST 90°C.
FIGURE 1
WARNING: FOR FIXTURES PROVIDED WITH 75˚ C OR
90˚ C SUPPLY WIRE WARNING ONLY (THESE WARN-
INGS ARE PROVIDED ON THE U.L. LABEL
AND ON THE FIXTURE CARTON).
WARNING: RISK OF FIRE. MOST DWELLINGS BUILT
BEFORE 1985 HAVE SUPPLY WIRE RATED 60˚ C.
CONSULT A QUALIFIED ELECTRICIAN BEFORE
INSTALLING.
DIFFUSER (G)
GROMMET (M)
SCREWS
JUNCTION BOX NUT
*WIRE
CONNECTOR
*OUTLET
BOX
JUNCTION BOX
COVER (N)
Installation And Safety
Instruction
HC-975 013007
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
Fill In Item Number On Carton And
File This Sheet For Fixture Reference. ITEM#_______________
HEX HEAD
SCREWS (F)
FRONT COVER (L)
*OUTLET BOX
SCREWS
* NOT SUPPLIED
HEX HEAD
NUTS (I)
END
CAPS (H)
*1” SHEET METAL
SCREWS (E)
INSTALLATION HC-975
FINAL ASSEMBLY
STEP 2:
STEP 4:
Install grommet (M) in 7/8” wireway knockout in back of fixture. Pass
black + white ballast wires through grommet. Proceed to step 4.
STEP 1:
Make sure no bare wires can be seen outside wire connectors.
Install lamps.
After wires are connected, tuck them carefully inside outlet box.
Push the fixture (D) firmly over outlet box and against the wall,
Secure in place with outlet box screws (not supplied). Use 1” sheet
metal screws (E) or toggle bolts (not included) to secure fixture to
wall. Attach front cover (L) to the fixture body using two hex head
sheet metal screws (F).
NOTE: IF MOUNTING TODRYWALL USE ENCLOSED DRY WALL
ANCHORS.
STEP 2:
Remove protective film from diffuser (G) (if applicable).
STEP 3:
Place diffuser (G) over fixture body and secure both end caps (H) in
place with two (2) hex head nuts (I).
NOTE: IN ORDER FOR THIS LIGHTING FIXTURE TO OPERATE
PROPERLY, THE BUILDING’S ELECTRICAL SYSTEM MUST BE
GROUNDED. IF YOU ARE UNCLEAR ON HOW TO PROCEED,
CONSULT A QUALIFIED ELECTRICIAN.
STEP 4:
A. Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
STEP 4:
*Note: When parallel wire is used, the tracer wire is square shaped
or ridged and less tracer wire is round in shape or smooth.
(Seen best when viewed from wire end.) To separate wires, grasp
the ends of each wire and pull apart.
B. Take your fixture wire(s) from group A and place evenly against
the black wire from the outlet box. DO NOT twist wires together
before using wire connectors.
C. Fit a wire connector (not supplied) over the wires and screw the
connector clockwise until you feel a firmness.
D. Try gently to pull the connector off the wires. If you can pull the
connector off, carefully re-do steps B and C, as above and check
again for a firm connection.
E. Connect the fixture wire from group B to the white wire from the
outlet box in the same manner.
GROUNDING INSTRUCTIONS: The green grounding screw is to
be inserted into the hole with two raised dimples provided on the
mounting bar (D). Wrap the ground wire from the fixture (if supplied)
and the ground wire from the outlet box (bare metal or green
insulated wire) around the green grounding screw on the
mounting bar (D) if uninsulated wire is on the mounting bar (D),
connect the ground wire from the fixture (if supplied) and the outlet
box to it using a small wire connector (not supplied).
NOTE: Underwriters Laboratories (U.L.) does not require all fixtures to
have ground wires. These fixtures still meet all U.L. specifications. The
listing mark of Underwriters on the product identifies products
manufactured under its listing and Follow-Up Service Programs.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
GROUP A: CONNECT TOBLACK
HOUSE WIRE
BLACK WHITE
*PARALLEL WIRE (ROUND & SMOOTH) *PARALLEL WIRE (SQUARE & RIDGED)
GROUP B: CONNECT TO WHITE
HOUSE WIRE
CLEANING
To clean, wipe fixture body with a soft cloth. Clean glass with a mild
soap. Do not use abrasive materials such as scouring pads,
powders, steel wool, or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. All parts for this fixture can be ordered from place
of purchase. Be sure to use exact wording from illustration when
ordering parts.
STEP 3:
STEP 1:
Install romex connector (not included) in 7/8” wireway knockout in
back of fixture. Pass black + white ballast wires through romex
connector and secure.
Line up junction box cover (N) with fixture so only the raised screw
hole surface actually contacts the fixture. Thread screws through
cover and fixture. Tighten with nut.
When mounting to a junction box begin with step 1. Otherwise
proceed to step 3
(Mounting to a junction box only)

Other Sea gull lighting Lighting Equipment manuals

Sea gull lighting Unique Lightscaping 91225-147 Programming manual

Sea gull lighting

Sea gull lighting Unique Lightscaping 91225-147 Programming manual

Sea gull lighting Windgate 3 44941 Series User manual

Sea gull lighting

Sea gull lighting Windgate 3 44941 Series User manual

Popular Lighting Equipment manuals by other brands

Lightolier F7000-18 Specification sheet

Lightolier

Lightolier F7000-18 Specification sheet

Cooper Lighting MT250 instruction manual

Cooper Lighting

Cooper Lighting MT250 instruction manual

Chauvet LEG-4500 user manual

Chauvet

Chauvet LEG-4500 user manual

emaux MFS20 user manual

emaux

emaux MFS20 user manual

Chauvet Professional Ovation F-265WW Quick reference guide

Chauvet Professional

Chauvet Professional Ovation F-265WW Quick reference guide

ETI Solid State Lighting 50242162 Use and care guide

ETI Solid State Lighting

ETI Solid State Lighting 50242162 Use and care guide

Coemar LineaLed Stick manual

Coemar

Coemar LineaLed Stick manual

Chauvet O-Beast user manual

Chauvet

Chauvet O-Beast user manual

B-K lighting MINI-MICRO DRIVESTAR installation instructions

B-K lighting

B-K lighting MINI-MICRO DRIVESTAR installation instructions

Century DSCD-1509040 quick start guide

Century

Century DSCD-1509040 quick start guide

Somogyi Elektronic DRM 16 quick start guide

Somogyi Elektronic

Somogyi Elektronic DRM 16 quick start guide

Graytechnos photom MiNi 365A instruction manual

Graytechnos

Graytechnos photom MiNi 365A instruction manual

Blizzard Lighting G-Mix 200 user guide

Blizzard Lighting

Blizzard Lighting G-Mix 200 user guide

VIBIA Tempo Assembly instructions

VIBIA

VIBIA Tempo Assembly instructions

Champlain ACM-124S quick start guide

Champlain

Champlain ACM-124S quick start guide

Colortran Status 12/24 user guide

Colortran

Colortran Status 12/24 user guide

HEISSNER L124-T Instructions for use

HEISSNER

HEISSNER L124-T Instructions for use

KOZii KV470FCCT instruction manual

KOZii

KOZii KV470FCCT instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.