Sealey CTI120 User manual

COMPACT R/CHARGE TYRE INFLATOR &
POWERBANK WITH WORK LIGHT
MODEL NO: CTI120
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Read operation instructions before use.
8DO NOT leave the unit unattended while in operation.
9 Checkcapacityandmaximuminationpressureofinatablebeforecommencingination.
9 Monitorthepressuregaugewhileinoperation.
9 Thegaugeshouldbeusedasanindicationofpressureonly.Werecommendtheuseofadialpressuregaugefordenitivereading.
WARNING!Thiscompressoriscapableofproducingahighpressure.
8DO NOTinateanyitembeyonditsmaximumcapacity.
8DO NOTdirectinationhoseconnectorheadatyourself,othersoranimals.
8DO NOTcarrybythehose,oryankthehosefromaninationvalve.
8DO NOT pull the power cable from the vehicle accessory socket by the power lead.
8DO NOTgetthecompressorwetoruseintherain.
8DO NOTusethecompressorforataskitwasnotdesignedtoperform.
8DO NOToperatethecompressorifanypartsaremissingasthismaycausefailureorpossiblepersonalinjury.
8DO NOT open the unit.
9 Keepchildrenandnonessentialpersonsawayfromtheinationarea.
9 Keepthecompressorcleanandingoodcondition.
9 Avoidbendingthehoseduringination.
9 Turnothepumpimmediatelyifoverheatingoranyabnormalityisobservedduringoperation.
9 Ifnopresetpressurevalue,DO NOTleavethepumpunattendedduringinationtopreventtheairpressuregettingtoohigh.
9 Keepthepumpawayfromanyammableorcombustibleobjectsduringoperation,sincethebuilt-inDCmotormaygeneratesparks
duringoperation.
9 Keepthepumpawayfrommoisture,sandandshock.
8DO NOTstorethepumpinextremelycoldorhotplaces.Thatwillshortenproductlife,damagebattery,ordeformthestructural.
9 Avoidusingstrongchemicalsordetergentstocleantheproduct.
8DO NOT disassemble the product. DO NOTthrowtheproductintoreorhouseholdwaste.
8DO NOT let children use the product.
8DO NOTinsertthehoseintomouth,ears,oreyesofhumansoranimals.Itmustnotbeusedasatoy.
9 Thiscompressorisnotdesignedforcontinuoususe.Operationoveranextendedperiodoftimewilloverheattheunitanddamage
thecompressor.Itshouldnotbeusedcontinuouslyformorethan30minutes.After30minutes,turnitoandletitcoolfor15
minutesbeforeresumingoperation.
CTI120Issue2(3)07/03/19
Original Language Version
© Jack Sealey Limited
Refer to
instructions

2. INTRODUCTION
Compactdigitaltyreinatorwithoutputof12ltr/min.Pressuregaugereadsupto120psi.140mmExtensiontubewithSchraderconnection.
MicroUSBrechargeable(cablenotsupplied).USBoutputforchargingmobilephoneetc.(5V/2A).Suppliedwithsportsballpinadaptor
andballoon/inatablesadaptor.Built-in1WSMDLEDforeaseofuseatnight.Presetthedesiredpsitobeginoperationandunitwillcutout
automaticallyoncethatpressureisreached.Autocut-outifhosekinks,toavoiddamagetopump.
1.OutletGrid 2.Pressuregauge 3. Reduce button 4.IncreaseButton
5.UnitButton 6.Start/Stopbutton 7.LEDLightingbutton 8.Indicator
9.Inletgrid 10.LEDLighting 11.HoseConnector 12.OutletGrid
13.USBoutputport 14.MicroUSBinputport 15.Airhose 16.4×Valveadapters
3. SPECIFICATION
HoseLength:.............................................................. 140mm
TypicalInationTime: .......... 0-30psiin619sec(175/70/R13)
MaximumPressure: .................................................... 120psi
Airow: ........................................................0.42cfm/12ltr/min
USB Output:................................................................. 5V/2A
Battery: ......................................................2000mAh/22.2Wh
4. OPERATION
4.1. CHARGING
4.1.1. Pleasechargethebatteryfullybeforeuse(g.2).Especially
forthersttimeorafteritisunusedforalongtime.Recommend
anUSBadapterwithoutputcapabilityof5V/1.5Aor5V/2A,
about4hoursforfullcharging.Otherfunctionsoftheproduct
arenotavailableduringcharging.
4.2. USING THE USB CHARGING PORT
4.2.1. USB output of CTI120isplugandplay
4.2.2. Theairpumpwillnotwork,whenyouare
chargingadevicefromthetyreinator.
TheUSBoutputwillturnoautomatically.
g.1
g.2
g.3
CTI120Issue2(3)07/03/18
Original Language Version
© Jack Sealey Limited

4.3. USING THE LED LIGHT
4.3.1. PresstheLEDlightbuttononce(g.4)toturnonthelight.Pressthebuttontwiceforaslowash,andthreetimesforaSOS
ashinglightpattern.
4.4. SETTING THE PRESSURE
NOTE:
• Whenthepre-setvalueislowerthanthevalueofperipheralpressure,theairpumpcannotbeactivated.
• CTI120hasanintegratedmechanismfortemperatureprotection.Self-protectionwillbeactivatedtostopexternalinationwhenthe
temperatureexceeds-15°Cto55°C.Itshouldnotbeusedcontinuouslyformorethan30minutes.After30minutes,turnitoandletit
coolfor15minutesbeforeresumingoperation.
• Arecommendedinationrangeislabelledonthesideoftyre.
4.4.1. Turnonthepressuregaugebypressingthe‘U’button(g.5).
4.5. SELECT PRESSURE UNIT
Afterturningonthepressuregauge,pressthe‘U’button(g.5)againtoselecttheairpressureunitsonthedisplay.
NOTE: Conversion relationship of related units is as follow
1PSI=6.89KPA 1BAR=100KPA 1Kg/cm²=98KPA
4.5.1. Tosettheoutputpressurevaluepressthe+or-buttons(g.6).
4.6. INFLATION
Connecttheinatableobjectasshownbelow.
4.6.1. Pressthestart/stopbutton(g.7)tostartinating.Whentheairpressureintheinatedobjectreachesthepresetairpressurevalue,
theairpumpstopsinatingautomatically.
4.6.2. Pressthestart/stopbuttoncanpauseduringtheination,thenpressagaintoresume.
g.4 g.5 g.6 g.7
g.8
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycleunwantedmaterialsinsteadofdisposingofthemaswaste.Alltools,accessoriesandpackagingshouldbesorted,takento
arecyclingcentreanddisposedofinamannerwhichiscompatiblewiththeenvironment.Whentheproductbecomescompletely
unserviceableandrequiresdisposal,drainanyfluids(ifapplicable)intoapprovedcontainersanddisposeoftheproductandfluids
accordingtolocalregulations.
WEEE REGULATIONS
DisposeofthisproductattheendofitsworkinglifeincompliancewiththeEUDirectiveonWasteElectricalandElectronicEquipment
(WEEE).Whentheproductisnolongerrequired,itmustbedisposedofinanenvironmentallyprotectiveway.Contactyourlocalsolid
wasteauthorityforrecyclinginformation.
Note:Itisourpolicytocontinuallyimproveproductsandassuchwereservetherighttoalterdata,specificationsandcomponentpartswithoutprior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty:Guaranteeis12monthsfrompurchasedate,proofofwhichisrequiredforanyclaim.
CTI120Issue2(3)07/03/19
Original Language Version
© Jack Sealey Limited
Table of contents
Other Sealey Accessories manuals

Sealey
Sealey MD520C-230V User manual

Sealey
Sealey HS107K User manual

Sealey
Sealey LED110S User manual

Sealey
Sealey LED3602 Series User manual

Sealey
Sealey SPB101 User manual

Sealey
Sealey EL144USB User manual

Sealey
Sealey EL144USB User manual

Sealey
Sealey CP20VTP User manual

Sealey
Sealey ga40 User manual

Sealey
Sealey BT2020 User manual